212 related articles for article (PubMed ID: 29138890)
1. Role of rapid kV-switching dual-energy CT in assessment of post-surgical local recurrence of pancreatic adenocarcinoma.
Parakh A; Patino M; Muenzel D; Kambadakone A; Sahani DV
Abdom Radiol (NY); 2018 Feb; 43(2):497-504. PubMed ID: 29138890
[TBL] [Abstract][Full Text] [Related]
2. Multireader evaluation of lesion conspicuity in small pancreatic adenocarcinomas: complimentary value of iodine material density and low keV simulated monoenergetic images using multiphasic rapid kVp-switching dual energy CT.
McNamara MM; Little MD; Alexander LF; Carroll LV; Beasley TM; Morgan DE
Abdom Imaging; 2015 Jun; 40(5):1230-40. PubMed ID: 25331567
[TBL] [Abstract][Full Text] [Related]
3. Lower energy levels and iodine-based material decomposition images increase pancreatic ductal adenocarcinoma conspicuity on rapid kV-switching dual-energy CT.
Aslan S; Camlidag I; Nural MS
Abdom Radiol (NY); 2019 Feb; 44(2):568-575. PubMed ID: 30155698
[TBL] [Abstract][Full Text] [Related]
4. Abdominal rapid-kVp-switching dual-energy MDCT with reduced IV contrast compared to conventional MDCT with standard weight-based IV contrast: an intra-patient comparison.
Clark ZE; Bolus DN; Little MD; Morgan DE
Abdom Imaging; 2015 Apr; 40(4):852-8. PubMed ID: 25261257
[TBL] [Abstract][Full Text] [Related]
5. Pancreatic ductal adenocarcinoma and chronic mass-forming pancreatitis: Differentiation with dual-energy MDCT in spectral imaging mode.
Yin Q; Zou X; Zai X; Wu Z; Wu Q; Jiang X; Chen H; Miao F
Eur J Radiol; 2015 Dec; 84(12):2470-6. PubMed ID: 26481480
[TBL] [Abstract][Full Text] [Related]
6. Rapid switching kVp dual energy CT: Value of reconstructed dual energy CT images and organ dose assessment in multiphasic liver CT exams.
Mahmood U; Horvat N; Horvat JV; Ryan D; Gao Y; Carollo G; DeOcampo R; Do RK; Katz S; Gerst S; Schmidtlein CR; Dauer L; Erdi Y; Mannelli L
Eur J Radiol; 2018 May; 102():102-108. PubMed ID: 29685522
[TBL] [Abstract][Full Text] [Related]
7. Dual energy CT angiography for lower extremity trauma: comparison with conventional CT.
Joshi R; LeBedis C; Dao K; Qureshi M; Gupta A
Emerg Radiol; 2022 Jun; 29(3):471-477. PubMed ID: 35246779
[TBL] [Abstract][Full Text] [Related]
8. Rapid kVp switching dual-energy CT in the assessment of urolithiasis in patients with large body habitus: preliminary observations on image quality and stone characterization.
Kordbacheh H; Baliyan V; Singh P; Eisner BH; Sahani DV; Kambadakone AR
Abdom Radiol (NY); 2019 Mar; 44(3):1019-1026. PubMed ID: 30415309
[TBL] [Abstract][Full Text] [Related]
9. Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: optimization of energy level viewing significantly increases lesion contrast.
Patel BN; Thomas JV; Lockhart ME; Berland LL; Morgan DE
Clin Radiol; 2013 Feb; 68(2):148-54. PubMed ID: 22889459
[TBL] [Abstract][Full Text] [Related]
10. Pancreatic Ductal Adenocarcinoma: Interface Enhancement Gradient Measured on Dual-Energy CT Images Improves Prognostic Evaluation.
Amer AM; Li Y; Summerlin D; Burgan CM; McNamara MM; Smith AD; Morgan DE
Radiol Imaging Cancer; 2020 Jul; 2(4):e190074. PubMed ID: 33778722
[TBL] [Abstract][Full Text] [Related]
11. Indirect computed tomography venography of the lower extremities using single-source dual-energy computed tomography: advantage of low-kiloelectron volt monochromatic images.
Kulkarni NM; Sahani DV; Desai GS; Kalva SP
J Vasc Interv Radiol; 2012 Jul; 23(7):879-86. PubMed ID: 22633619
[TBL] [Abstract][Full Text] [Related]
12. Benefit of iodine density images to reduce out-of-field image artifacts at rapid kVp switching dual-energy CT.
Dotson B; Lambert JW; Wang ZJ; Sun Y; Ohliger MA; Winklhofer S; Yeh BM
Abdom Radiol (NY); 2017 Mar; 42(3):735-741. PubMed ID: 27847997
[TBL] [Abstract][Full Text] [Related]
13. Dual-energy perfusion-CT of pancreatic adenocarcinoma.
Klauss M; Stiller W; Pahn G; Fritz F; Kieser M; Werner J; Kauczor HU; Grenacher L
Eur J Radiol; 2013 Feb; 82(2):208-14. PubMed ID: 23062281
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of Virtual Monoenergetic Images on Pulmonary Vasculature Using the Dual-Layer Detector-Based Spectral Computed Tomography.
Ghandour A; Sher A; Rassouli N; Dhanantwari A; Rajiah P
J Comput Assist Tomogr; 2018; 42(6):858-865. PubMed ID: 29659426
[TBL] [Abstract][Full Text] [Related]
15. Iodine concentration and tissue attenuation in dual-energy contrast-enhanced CT as a potential quantitative parameter in early detection of local pancreatic carcinoma recurrence after surgical resection.
Mathy RM; Fritz F; Mayer P; Klauss M; Grenacher L; Stiller W; Kauczor HU; Skornitzke S
Eur J Radiol; 2021 Oct; 143():109944. PubMed ID: 34482176
[TBL] [Abstract][Full Text] [Related]
16. Virtual monochromatic image at lower energy level for assessing pancreatic ductal adenocarcinoma in fast kV-switching dual-energy CT.
Noda Y; Goshima S; Kaga T; Ando T; Miyoshi T; Kawai N; Kawada H; Tanahashi Y; Matsuo M
Clin Radiol; 2020 Apr; 75(4):320.e17-320.e23. PubMed ID: 31879024
[TBL] [Abstract][Full Text] [Related]
17. Virtual Monochromatic Images from Dual-Energy Multidetector CT: Variance in CT Numbers from the Same Lesion between Single-Source Projection-based and Dual-Source Image-based Implementations.
Mileto A; Barina A; Marin D; Stinnett SS; Roy Choudhury K; Wilson JM; Nelson RC
Radiology; 2016 Apr; 279(1):269-77. PubMed ID: 26536403
[TBL] [Abstract][Full Text] [Related]
18. Single-energy low-voltage arterial phase MDCT scanning increases conspicuity of adenocarcinoma of the pancreas.
Zamboni GA; Ambrosetti MC; Guariglia S; Cavedon C; Pozzi Mucelli R
Eur J Radiol; 2014 Mar; 83(3):e113-7. PubMed ID: 24447420
[TBL] [Abstract][Full Text] [Related]
19. Dual-energy CT of the pancreas: improved carcinoma-to-pancreas contrast with a noise-optimized monoenergetic reconstruction algorithm.
Frellesen C; Fessler F; Hardie AD; Wichmann JL; De Cecco CN; Schoepf UJ; Kerl JM; Schulz B; Hammerstingl R; Vogl TJ; Bauer RW
Eur J Radiol; 2015 Nov; 84(11):2052-8. PubMed ID: 26220917
[TBL] [Abstract][Full Text] [Related]
20. A Single Enhanced Dual-Energy CT Scan May Distinguish Lung Squamous Cell Carcinoma From Adenocarcinoma During the Venous phase.
Zhang Z; Zou H; Yuan A; Jiang F; Zhao B; Liu Y; Chen J; Zuo M; Gong L
Acad Radiol; 2020 May; 27(5):624-629. PubMed ID: 31447258
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]