240 related articles for article (PubMed ID: 29144629)
1. Single perineal incision placement of artificial urinary sphincter with cadaveric correlation of sub-dartos pump placement.
Benson CR; Ayoub HI; Westney OL
Int Braz J Urol; 2018; 44(2):355-361. PubMed ID: 29144629
[TBL] [Abstract][Full Text] [Related]
2. Management of end-stage erectile dysfunction and stress urinary incontinence after radical prostatectomy by simultaneous dual implantation using a single trans-scrotal incision: surgical technique and outcomes.
Martínez-Salamanca JI; Espinós EL; Moncada I; Portillo LD; Carballido J
Asian J Androl; 2015; 17(5):792-6. PubMed ID: 25657083
[TBL] [Abstract][Full Text] [Related]
3. Combined inflatable penile prosthesis-artificial urinary sphincter implantation: no increased risk of adverse events compared to single or staged device implantation.
Segal RL; Cabrini MR; Harris ED; Mostwin JL; Bivalacqua TJ; Burnett AL
J Urol; 2013 Dec; 190(6):2183-8. PubMed ID: 23831315
[TBL] [Abstract][Full Text] [Related]
4. Transcorporal artificial urinary sphincter implantation as a salvage surgical procedure for challenging cases of male stress urinary incontinence: surgical technique and functional outcomes in a contemporary series.
Wiedemann L; Cornu JN; Haab E; Peyrat L; Beley S; Cathelineau X; Haab F
BJU Int; 2013 Dec; 112(8):1163-8. PubMed ID: 24053170
[TBL] [Abstract][Full Text] [Related]
5. Perineal approach for artificial urinary sphincter implantation appears to control male stress incontinence better than the transscrotal approach.
Henry GD; Graham SM; Cleves MA; Simmons CJ; Flynn B
J Urol; 2008 Apr; 179(4):1475-9; discussion 1479. PubMed ID: 18295275
[TBL] [Abstract][Full Text] [Related]
6. Revisiting the penoscrotal approach to artificial urinary sphincter surgery: how does it compare to a perineal incision for initial implantation?
Staniorski CJ; Singal A; Nettey O; Yura E; Keeter MK; Kielb S; Hofer MD
World J Urol; 2021 Mar; 39(3):871-876. PubMed ID: 32440696
[TBL] [Abstract][Full Text] [Related]
7. Synchronous Ipsilateral High Submuscular Placement of Prosthetic Balloons and Reservoirs.
Kavoussi NL; Hofer MD; Viers BR; Cordon BH; Mooney RP; Pagliara TJ; Scott JM; Morey AF
J Sex Med; 2017 Feb; 14(2):264-268. PubMed ID: 28089244
[TBL] [Abstract][Full Text] [Related]
8. Contemporary Review of Artificial Urinary Sphincters for Male Stress Urinary Incontinence.
Yafi FA; Powers MK; Zurawin J; Hellstrom WJ
Sex Med Rev; 2016 Apr; 4(2):157-166. PubMed ID: 27872025
[TBL] [Abstract][Full Text] [Related]
9. Is Removal of the Pressure-regulating Balloon Necessary After Artificial Urinary Sphincter Cuff Erosion?
Rozanski AT; Viers BR; Shakir NA; Pagliara TJ; Scott JM; Morey AF
Urology; 2018 Mar; 113():225-229. PubMed ID: 29155193
[TBL] [Abstract][Full Text] [Related]
10. Robot-assisted laparoscopic approach for artificial urinary sphincter implantation in 11 women with urinary stress incontinence: surgical technique and initial experience.
Biardeau X; Rizk J; Marcelli F; Flamand V
Eur Urol; 2015 May; 67(5):937-42. PubMed ID: 25582931
[TBL] [Abstract][Full Text] [Related]
11. Safety of the "drain and retain" option for defunctionalized urologic prosthetic balloons and reservoirs during artificial urinary sphincter and inflatable penile prosthesis revision surgery: 5-year experience.
Cefalu CA; Deng X; Zhao LC; Scott JF; Mehta S; Morey AF
Urology; 2013 Dec; 82(6):1436-9. PubMed ID: 24125688
[TBL] [Abstract][Full Text] [Related]
12. Tandem cuff artificial urinary sphincter as a salvage procedure following failed primary sphincter placement for the treatment of post-prostatectomy incontinence.
DiMarco DS; Elliott DS
J Urol; 2003 Oct; 170(4 Pt 1):1252-4. PubMed ID: 14501735
[TBL] [Abstract][Full Text] [Related]
13. Outcomes of simultaneous placement of an inflatable penile prosthesis and a male urethral sling through a single perineal incision.
Gorbatiy V; Westney OL; Romero C; Wang R
J Sex Med; 2010 Feb; 7(2 Pt 1):832-8. PubMed ID: 19796057
[TBL] [Abstract][Full Text] [Related]
14. High submuscular placement of urologic prosthetic balloons and reservoirs via transscrotal approach.
Morey AF; Cefalu CA; Hudak SJ
J Sex Med; 2013 Feb; 10(2):603-10. PubMed ID: 23216955
[TBL] [Abstract][Full Text] [Related]
15. [Asynchronous implantation of a penile prosthesis (AMS 700) in patients with an artificial urinary sphincter (AMS 800): what functional outcomes can we expect from the AMS 1500?].
Alechinsky L; Phé V; Yates DR; Bourgade V; Parra J; Richard F; Chartier-Kastler E; Bitker MO; Rouprêt M
Prog Urol; 2010 May; 22(6):354-9. PubMed ID: 22541906
[TBL] [Abstract][Full Text] [Related]
16. Erosion rates of 3.5-cm artificial urinary sphincter cuffs are similar to larger cuffs.
McKibben MJ; Shakir N; Fuchs JS; Scott JM; Morey AF
BJU Int; 2019 Feb; 123(2):335-341. PubMed ID: 30007096
[TBL] [Abstract][Full Text] [Related]
17. New enhancements of the scrotal one-incision technique for placement of artificial urinary sphincter allow proximal cuff placement.
Wilson SK; Aliotta PJ; Salem EA; Mulcahy JJ
J Sex Med; 2010 Oct; 7(10):3510-5. PubMed ID: 20584110
[TBL] [Abstract][Full Text] [Related]
18. Combined Placement of Artificial Urinary Sphincter and Inflatable Penile Prosthesis Does Not Increase Risk of Perioperative Complications or Impact Long-term Device Survival.
Boysen WR; Cohen AJ; Kuchta K; Park S; Milose J
Urology; 2019 Feb; 124():264-270. PubMed ID: 30786981
[TBL] [Abstract][Full Text] [Related]
19. Laparoscopic approach for artificial urinary sphincter implantation in women with intrinsic sphincter deficiency incontinence: a single-centre preliminary experience.
Rouprêt M; Misraï V; Vaessen C; Cardot V; Cour F; Richard F; Chartier-Kastler E
Eur Urol; 2010 Mar; 57(3):499-504. PubMed ID: 19346059
[TBL] [Abstract][Full Text] [Related]
20. [Laparoscopic approach for artificial urinary sphincter implantation in women with severe urinary stress incontinence].
Trolliet S; Mandron E; Lang H; Jacqmin D; Saussine C
Prog Urol; 2013 Sep; 23(10):877-83. PubMed ID: 24034800
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]