These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

368 related articles for article (PubMed ID: 29145233)

  • 21. [Advances in interventional occlusion of persistent ductus arteriosus: comparison of results using different occlusion devices].
    Koch A; Hofbeck M; Buheitel G; Gerling S; Rauch R; Singer H
    Z Kardiol; 2001 Feb; 90(2):120-6. PubMed ID: 11263001
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Incidence and fate of device-related left pulmonary artery stenosis and aortic coarctation in small infants undergoing transcatheter patent ductus arteriosus closure.
    Tomasulo CE; Gillespie MJ; Munson D; Demkin T; O'Byrne ML; Dori Y; Smith CL; Rome JJ; Glatz AC
    Catheter Cardiovasc Interv; 2020 Oct; 96(4):889-897. PubMed ID: 32339400
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Transcatheter device closure of patent ductus arteriosus.
    Sultan M; Ullah M; Sadiq N; Akhtar K; Akbar H
    J Coll Physicians Surg Pak; 2014 Oct; 24(10):710-3. PubMed ID: 25327911
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The Amplatzer Duct Occluder II Additional Sizes device for transcatheter PDA closure: initial experience.
    Bruckheimer E; Godfrey M; Dagan T; Levinzon M; Amir G; Birk E
    Catheter Cardiovasc Interv; 2014 Jun; 83(7):1097-101. PubMed ID: 24532416
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder in children: initial and one-year results].
    Parra-Bravo JR; Cruz-Ramírez A; Toxqui-Terán A; Juan-Martínez E; Chávez-Fernández AA; Lazo-Cárdenas C; Beirana-Palencia L; Estrada-Flores J
    Arch Cardiol Mex; 2009; 79(2):114-20. PubMed ID: 19722381
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Further experience with catheter closure of patent ductus arteriosus using the new Amplatzer duct occluder in children.
    Thanopoulos BV; Eleftherakis N; Tzannos K; Stefanadis C; Giannopoulos A
    Am J Cardiol; 2010 Apr; 105(7):1005-9. PubMed ID: 20346321
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Percutaneous closure of patent ductus arteriosus in children using amplatzer duct occluder II: relationship between PDA type and risk of device protrusion into the descending aorta.
    Masri S; El Rassi I; Arabi M; Tabbakh A; Bitar F
    Catheter Cardiovasc Interv; 2015 Aug; 86(2):E66-72. PubMed ID: 26032159
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Long-term outcome of transcatheter coil closure of small to large patent ductus arteriosus.
    Patel HT; Cao QL; Rhodes J; Hijazi ZM
    Catheter Cardiovasc Interv; 1999 Aug; 47(4):457-61. PubMed ID: 10470477
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Safety of transcatheter patent ductus arteriosus closure in small weight infants.
    Drighil A; Al Jufan M; Al Omrane K; Al Atta J; Al Omrani A; Al Fadley F
    J Interv Cardiol; 2012 Aug; 25(4):391-4. PubMed ID: 22574623
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Percutaneous closure of the patent ductus arteriosus using the Nit-Occlud PDA-R (reverse) device: initial experience reporting immediate and short-term results.
    Peirone A; Diaz J; Contreras A; Banille E; Cabrera M; Spillmann A; Bueno N; Juaneda E
    J Invasive Cardiol; 2011 Dec; 23(12):513-6. PubMed ID: 22147399
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Closure of patent ductus arteriosus in children, small infants, and premature babies with Amplatzer duct occluder II additional sizes: multicenter study.
    Sungur M; Karakurt C; Ozbarlas N; Baspinar O
    Catheter Cardiovasc Interv; 2013 Aug; 82(2):245-52. PubMed ID: 23460349
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Transcatheter Closure of Patent Ductus Arteriosus in Adolescents and Adults: A Case Series.
    Putra ST; Djer MM; Idris NS; Sastroasmoro S
    Acta Med Indones; 2016 Oct; 48(4):314-319. PubMed ID: 28143993
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Percutaneous closure of patent ductus arteriosus: short term results].
    Kaya Y; Bulut MO; Yurtdaş M; Karakurt A; Güvenç TS; Söylemez N; Güler A; Gönüllü E; Ceylan Y; Akdemir R
    Turk Kardiyol Dern Ars; 2013 Jun; 41(4):310-8. PubMed ID: 23760118
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Further experience with transcatheter closure of the patent ductus arteriosus using the Amplatzer duct occluder.
    Thanopoulos BD; Hakim FA; Hiari A; Goussous Y; Basta E; Zarayelyan AA; Tsaousis GS
    J Am Coll Cardiol; 2000 Mar; 35(4):1016-21. PubMed ID: 10732903
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Trans-pulmonary echocardiography as a guide for device closure of patent ductus arteriosus.
    Kudo Y; Suda K; Yoshimoto H; Teramachi Y; Kishimoto S; Iemura M; Matsuishi T
    Catheter Cardiovasc Interv; 2015 Aug; 86(2):264-70. PubMed ID: 25676054
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Transcatheter occlusion of the patent ductus arteriosus in premature infants weighing less than 1200 g.
    Morville P; Douchin S; Bouvaist H; Dauphin C
    Arch Dis Child Fetal Neonatal Ed; 2018 May; 103(3):F198-F201. PubMed ID: 29066474
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Cocoon devices for transcatheter closure of atrial septal defect and patent ductus arteriosus in children: Single center experience.
    Mahmoud H; Nicolescu A; Filip C; Duica G; Nicolae G; Cinteza EE
    Medicine (Baltimore); 2019 Mar; 98(10):e14684. PubMed ID: 30855458
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Short-Term Outcomes of Patent Ductus Arteriosus Closure With New Occlutech® Duct Occluder: A Multicenter Study.
    Dedeoglu R; Bilici M; Demir F; Demir F; Acar OÇ; Hallioglu O; Pac A; Kiziltas A; Karabel D; Kula S; Cimen D; Baspinar O; Atik SU; Saltik IL
    J Interv Cardiol; 2016 Jun; 29(3):325-31. PubMed ID: 27090770
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The Amplatzer duct occluder: experience in 209 patients.
    Bilkis AA; Alwi M; Hasri S; Haifa AL; Geetha K; Rehman MA; Hasanah I
    J Am Coll Cardiol; 2001 Jan; 37(1):258-61. PubMed ID: 11153748
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Transcatheter closure of patent ductus arteriosus using Gianturco coils in adolescents and adults.
    Wang JK; Liau CS; Huang JJ; Hsu KL; Lo PH; Hung JS; Wu MH; Lee YT
    Catheter Cardiovasc Interv; 2002 Apr; 55(4):513-8. PubMed ID: 11948902
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 19.