These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 29145735)

  • 1. Evaluation of Performance of Laboratories and Manufacturers Within the Framework of the IFCC model for Quality Targets of HbA1c.
    Weykamp C; Siebelder C
    J Diabetes Sci Technol; 2018 Jul; 12(4):747-752. PubMed ID: 29145735
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Japanese standard reference material for JDS Lot 2 haemoglobin A1c. I: Comparison of Japan Diabetes Society-assigned values to those obtained by the Japanese and USA domestic standardization programmes and by the International Federation of Clinical Chemistry reference laboratories.
    Tominaga M; Makino H; Yoshino G; Kuwa K; Takei I; Aono Y; Hoshino T; Umemoto M; Shimatsu A; Sanke T; Kuwashima M; Taminato T; Ono J
    Ann Clin Biochem; 2005 Jan; 42(Pt 1):41-6. PubMed ID: 15802031
    [TBL] [Abstract][Full Text] [Related]  

  • 3. HbA1c: EQA in Germany, Belgium and the Netherlands using fresh whole blood samples with target values assigned with the IFCC reference system.
    Kaiser P; Spannagl M; van Campenhout C; Lenga Y; Siebelder C; Weykamp C
    Clin Chem Lab Med; 2016 Nov; 54(11):1769-1775. PubMed ID: 27171390
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Standardization and analytical goals for glycated hemoglobin measurement.
    Braga F; Panteghini M
    Clin Chem Lab Med; 2013 Sep; 51(9):1719-26. PubMed ID: 23729573
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Standardization of HbA1c and Optimal Range of Monitoring.
    Miedema K
    Scand J Clin Lab Invest Suppl; 2005; 240():61-72. PubMed ID: 16112961
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The National Glycohemoglobin Standardization Program: Over 20 Years of Improving Hemoglobin A
    Little RR; Rohlfing C; Sacks DB
    Clin Chem; 2019 Jul; 65(7):839-848. PubMed ID: 30518660
    [TBL] [Abstract][Full Text] [Related]  

  • 7. HbA1c: a comparison of NGSP with IFCC transformed values.
    Dhatt GS; Agarwal MM; Bishawi B
    Clin Chim Acta; 2005 Aug; 358(1-2):81-6. PubMed ID: 16018879
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessing quality on the Sigma scale from proficiency testing and external quality assessment surveys.
    Westgard JO; Westgard SA
    Clin Chem Lab Med; 2015 Sep; 53(10):1531-5. PubMed ID: 25719323
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Application of biological variation and sigma metrics to evaluate the performance of HbA
    Kang F; Li W; Lou Y; Shan Z
    Scand J Clin Lab Invest; 2022 Sep; 82(5):398-403. PubMed ID: 35872643
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of HbA1c as Monitored by External Quality Assessment and Compared With Patient Mean Values.
    Nordin G
    J Diabetes Sci Technol; 2018 Jul; 12(4):771-779. PubMed ID: 29916732
    [TBL] [Abstract][Full Text] [Related]  

  • 11. EurA1c: The European HbA1c Trial to Investigate the Performance of HbA1c Assays in 2166 Laboratories across 17 Countries and 24 Manufacturers by Use of the IFCC Model for Quality Targets.
    EurA1c Trial Group
    Clin Chem; 2018 Aug; 64(8):1183-1192. PubMed ID: 29921723
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Standardization of two immunological HbA1c routine assays according to the new IFCC reference method.
    Groche D; Hoeno W; Hoss G; Vogt B; Herrmann Z; Witzigmann A
    Clin Lab; 2003; 49(11-12):657-61. PubMed ID: 14651337
    [TBL] [Abstract][Full Text] [Related]  

  • 13. HbA1c: a review of analytical and clinical aspects.
    Weykamp C
    Ann Lab Med; 2013 Nov; 33(6):393-400. PubMed ID: 24205486
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance evaluation of the Arkray Adams HA-8160 HbA1c analyser.
    Thevarajah TM; Nani N; Chew YY
    Malays J Pathol; 2008 Dec; 30(2):81-6. PubMed ID: 19291916
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The global impact of the International Federation of Clinical Chemistry and Laboratory Medicine, Education and Management Division: engaging stakeholders and assessing HbA1c quality in a multicentre study across China.
    English E; Weykamp C; Ji L; Siebelder C; Shan Z; Wang Y; Li H; Garry John W
    Clin Chem Lab Med; 2018 Dec; 57(2):288-295. PubMed ID: 30044761
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Nanjing Glycated Hemoglobin Standardization Program: 2012 to 2015.
    Zhang K; Wang Y; Wei H; Xu Z
    Clin Ther; 2017 Jan; 39(1):220-229. PubMed ID: 27919520
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Need for Accuracy in Hemoglobin A1c Proficiency Testing: Why the Proposed CLIA Rule of 2019 Is a Step Backward.
    Klonoff DC; Aron D; Cohen RM; Home P; John WG; Little RR; Nathan DM; Sacks DB
    J Diabetes Sci Technol; 2019 May; 13(3):424-427. PubMed ID: 30897963
    [No Abstract]   [Full Text] [Related]  

  • 18. National continuous surveys on internal quality control for HbA1c in 306 clinical laboratories of China from 2012 to 2016: Continual improvement.
    Li T; Wang W; Zhao H; He F; Zhong K; Yuan S; Wang Z
    J Clin Lab Anal; 2017 Sep; 31(5):. PubMed ID: 27868236
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Best use of the recommended IFCC reference method, material and values in HbA1C analyses.
    Penttilä IM; Halonen T; Punnonen K; Tiikkainen U
    Scand J Clin Lab Invest; 2005; 65(6):453-62. PubMed ID: 16179278
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of HbA1C results in an external quality assessment scheme in South Africa.
    Dhatt GS; Pum JK; Viljoen A; Jenner W
    Clin Chim Acta; 2003 May; 331(1-2):147-51. PubMed ID: 12691875
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.