These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
140 related articles for article (PubMed ID: 29153027)
21. Determination of carbohydrate-deficient transferrin in human serum with capillary zone electrophoresis. Sample preparation strategies for the removal of interferences caused by increased levels of immunoglobulins. Lanz C; Falmagne JB; de l'Escaille F; Marti U; Thormann W J Chromatogr A; 2008 Oct; 1206(1):33-40. PubMed ID: 18533168 [TBL] [Abstract][Full Text] [Related]
22. Parallelism between width and asymmetry of peaks of rigid, spherical particles in capillary zone electrophoresis using polymer solutions. Radko SP; Chrambach A Electrophoresis; 1998 Jul; 19(10):1620-4. PubMed ID: 9719536 [TBL] [Abstract][Full Text] [Related]
23. [Improvement of carbohydrate deficient transferrin measurement by capillary zone electrophoresis using immunosubtraction of immunoglobulins and transferrin]. Baraud J; Schellenberg F; Pagès JC Ann Biol Clin (Paris); 2009; 67(4):451-5. PubMed ID: 19654087 [TBL] [Abstract][Full Text] [Related]
24. Monoclonal gammopathy missed by capillary zone electrophoresis. Schild C; Egger F; Kaelin-Lang A; Nuoffer JM Clin Chem Lab Med; 2011 Jul; 49(7):1217-9. PubMed ID: 21574878 [TBL] [Abstract][Full Text] [Related]
25. Inability to Measure M-Protein With Capillary Zone Electrophoresis (CAPPILLARYS 2) in Tracings With NonDiscernable Peaks. Huang RS; Dasgupta A; Nguyen AN; Wahed A J Clin Lab Anal; 2015 Sep; 29(5):343-6. PubMed ID: 25130914 [TBL] [Abstract][Full Text] [Related]
26. Comparison of serum protein electrophoresis by agarose gel and capillary zone electrophoresis in a clinical setting. Jolliff CR; Blessum CR Electrophoresis; 1997 Sep; 18(10):1781-4. PubMed ID: 9372270 [TBL] [Abstract][Full Text] [Related]
27. Evaluation of a new capillary zone electrophoresis system for the identification and typing of Bence Jones Protein. Mussap M; Ponchia S; Zaninotto M; Varagnolo M; Plebani M Clin Biochem; 2006 Feb; 39(2):152-9. PubMed ID: 16337932 [TBL] [Abstract][Full Text] [Related]
28. Performance comparison of capillary and agarose gel electrophoresis for the identification and characterization of monoclonal immunoglobulins. McCudden CR; Mathews SP; Hainsworth SA; Chapman JF; Hammett-Stabler CA; Willis MS; Grenache DG Am J Clin Pathol; 2008 Mar; 129(3):451-8. PubMed ID: 18285269 [TBL] [Abstract][Full Text] [Related]
29. Prospective study of serum protein capillary zone electrophoresis and immunotyping of monoclonal proteins by immunosubtraction. Katzmann JA; Clark R; Sanders E; Landers JP; Kyle RA Am J Clin Pathol; 1998 Oct; 110(4):503-9. PubMed ID: 9763037 [TBL] [Abstract][Full Text] [Related]
30. Measurement of serum monoclonal components: comparison between densitometry and capillary zone electrophoresis. Mussap M; Pietrogrande F; Ponchia S; Stefani PM; Sartori R; Plebani M Clin Chem Lab Med; 2006; 44(5):609-11. PubMed ID: 16681432 [TBL] [Abstract][Full Text] [Related]
31. [Detecting a peak in fraction beta by capillary electrophoresis: interference due to iomeprol]. Wils J; Lavoinne A; Vaillant C Ann Biol Clin (Paris); 2013; 71(2):196-8. PubMed ID: 23587586 [TBL] [Abstract][Full Text] [Related]
33. Heavy/light chain specific immunoglobulin ratios provides no additional information than serum proteins electrophoresis and immunofixation for the diagnosis and the follow-up of intact immunoglobulin multiple myeloma patients. Beaumont-Epinette MP; Moreau C; Besnard S; Latute F; Collet N; Sebillot M; Grosbois B; Bendavid C; Guenet L; Decaux O Pathol Biol (Paris); 2015 Sep; 63(4-5):215-21. PubMed ID: 26319969 [TBL] [Abstract][Full Text] [Related]
34. Peak capacity and peak capacity per unit time in capillary and microchip zone electrophoresis. Foley JP; Blackney DM; Ennis EJ J Chromatogr A; 2017 Nov; 1523():80-89. PubMed ID: 28864108 [TBL] [Abstract][Full Text] [Related]
35. On-line post-capillary affinity detection of immunoglobulin G for capillary zone electrophoresis. Chen J; Lee CS J Chromatogr B Analyt Technol Biomed Life Sci; 2002 Feb; 768(1):105-11. PubMed ID: 11939543 [TBL] [Abstract][Full Text] [Related]
36. A triclonal gammopathy in a relapsing multiple myeloma patient, detected by immunosubtraction method. Aksungar FB; Ayer M; Serteser M; Coskun A; Unsal I Ann Clin Biochem; 2014 Sep; 51(Pt 5):606-10. PubMed ID: 24361990 [TBL] [Abstract][Full Text] [Related]
37. Conflicting results between electrophoresis methods of serum M-proteins. Wuyts B; Bossuyt X; Verhoef G; Blanckaert N; Delanghe JR Electrophoresis; 2004 Jun; 25(10-11):1548-50. PubMed ID: 15188240 [TBL] [Abstract][Full Text] [Related]
38. Success and failure with phthalate buffers in capillary zone electrophoresis. Bocek P; Gebauer P; Beckers JL Electrophoresis; 2001 Apr; 22(6):1106-11. PubMed ID: 11358134 [TBL] [Abstract][Full Text] [Related]
39. Estimation of serum M-protein concentration from polyclonal immunoglobulins: an alternative to serum protein electrophoresis and standard immunochemical procedures. Bergón E; Miravalles E Clin Chem Lab Med; 2008; 46(8):1156-62. PubMed ID: 18605957 [TBL] [Abstract][Full Text] [Related]