BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

216 related articles for article (PubMed ID: 29153933)

  • 1. Computed Tomographic Window Setting for Bronchial Measurement to Guide Double-Lumen Tube Size.
    Seo JH; Bae J; Paik H; Koo CH; Bahk JH
    J Cardiothorac Vasc Anesth; 2018 Apr; 32(2):863-868. PubMed ID: 29153933
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison between computerized tomography-guided bronchial width measurement versus conventional method for selection of adequate double lumen tube size.
    Suvvari P; Kumar B; Singhal M; Singh H
    Ann Card Anaesth; 2019; 22(4):358-364. PubMed ID: 31621669
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Predicting the size of a double-lumen endobronchial tube using computed tomographic scan measurements of the left main bronchus diameter.
    Chow MY; Liam BL; Thng CH; Chong BK
    Anesth Analg; 1999 Feb; 88(2):302-5. PubMed ID: 9972745
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter.
    Hannallah M; Benumof JL; Silverman PM; Kelly LC; Lea D
    J Cardiothorac Vasc Anesth; 1997 Apr; 11(2):168-71. PubMed ID: 9105987
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Common double-lumen tube selection methods overestimate adequate tube sizes in individual patients - a 3D reconstruction study.
    Mihatsch LL; Weiland S; Helmberger T; Friederich P
    BMC Anesthesiol; 2024 Jul; 24(1):215. PubMed ID: 38956485
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characteristics of Double-Lumen Tubes Determine Bronchial Airway Pressure.
    Spaeth J; Hojnik A; Ott M; Wirth S; Schneider M; Loop T; Schumann S
    J Cardiothorac Vasc Anesth; 2016 Aug; 30(4):954-60. PubMed ID: 27521966
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of the True Inclination Angle of the Main Bronchi Relative to the Median Sagittal Plane for Placement of a Left-Sided Double-Lumen Tube.
    Patel RV; Van Noord BA; Patel D; Hong EJ; Bourne E; Patel RR; Chandrasoma J; Chan L; Szenohradszki J; Lumb PD
    J Cardiothorac Vasc Anesth; 2017 Apr; 31(2):434-440. PubMed ID: 27600930
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Analysis of the association between double-lumen endobronchial tube and inner diameter of the left main bronchus].
    Cui JX; Zhao GD; Huang WQ
    Di Yi Jun Yi Da Xue Xue Bao; 2005 Jul; 25(7):799-801. PubMed ID: 16027071
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Can ultrasound be useful for predicting the size of a left double-lumen bronchial tube? Tracheal width as measured by ultrasonography versus computed tomography.
    Sustić A; Miletić D; Protić A; Ivancić A; Cicvarić T
    J Clin Anesth; 2008 Jun; 20(4):247-52. PubMed ID: 18617120
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Use of tracheal ultrasound combined with clinical parameters to select left double-lumen tube size: A prospective observational study.
    Roldi E; Inghileri P; Dransart-Raye O; Mongodi S; Guinot PG; Mojoli F; Bouhemad B
    Eur J Anaesthesiol; 2019 Mar; 36(3):215-220. PubMed ID: 30540641
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prediction of Double-Lumen Tube Size By Ultrasonography for Asian Women: A Prospective Observational Study.
    Liu S; Zhou J; Qi W; Cheng L; Dong Y
    J Cardiothorac Vasc Anesth; 2021 May; 35(5):1410-1415. PubMed ID: 32859488
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial.
    Seo JH; Yoon S; Min SH; Row HS; Bahk JH
    PLoS One; 2019; 14(1):e0210711. PubMed ID: 30645611
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Compatibility of left-sided double-lumen endobronchial tubes with tracheal and bronchial dimensions: a retrospective comparative study.
    Ellensohn J; Hillermann T; Steinauer A; Hegland N; Schnitzler S; Welter J; Weiss M; Dullenkopf A
    Minerva Anestesiol; 2022 Mar; 88(3):121-128. PubMed ID: 34527406
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Combination of Diameters of Cricoid Ring and Left Main Bronchus for Selecting the "Best Fit" Double-Lumen Tube.
    Shiqing L; Wenxu Q; Jin Z; Youjing D
    J Cardiothorac Vasc Anesth; 2018 Apr; 32(2):869-876. PubMed ID: 29361456
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Choosing the correct-sized adult double-lumen tube: Quest for the holy grail.
    Shah SB; Hariharan U; Chawla R
    Ann Card Anaesth; 2023; 26(2):124-132. PubMed ID: 37706375
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The relationship between tracheal width and left bronchial width: Implications for left-sided double-lumen tube selection.
    Brodsky JB; Malott K; Angst M; Fitzmaurice BG; Kee SP; Logan L
    J Cardiothorac Vasc Anesth; 2001 Apr; 15(2):216-7. PubMed ID: 11312482
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Computed tomography-based tracheobronchial image reconstruction allows selection of the individually appropriate double-lumen tube size.
    Eberle B; Weiler N; Vogel N; Kauczor HU; Heinrichs W
    J Cardiothorac Vasc Anesth; 1999 Oct; 13(5):532-7. PubMed ID: 10527220
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparison of the reliability of two techniques of left double-lumen tube bronchial cuff inflation in producing water-tight seal of the left mainstem bronchus.
    Hannallah MS; Gharagozloo F; Gomes MN; Chase GA
    Anesth Analg; 1998 Nov; 87(5):1027-31. PubMed ID: 9806676
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A new and simple maneuver to position the left-sided double-lumen tube without the aid of fiberoptic bronchoscopy.
    Bahk JH; Oh YS
    Anesth Analg; 1998 Jun; 86(6):1271-5. PubMed ID: 9620518
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Measurement of the Minimum Pressure in the Bronchial Cuff during One-lung Ventilation Using a Capnometer].
    Okubo H; Kawasaki T; Shibayama A; Sata T
    Masui; 2015 Aug; 64(8):794-8. PubMed ID: 26442408
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.