BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 2915787)

  • 21. Brainstem auditory evoked potentials (BAEPs) pathology in topographical diagnosis of posterior fossa lesions.
    Koprdová I; Cigánek L
    Mol Chem Neuropathol; 1995; 25(2-3):103-13. PubMed ID: 8534313
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Intraoperative monitoring of brainstem auditory evoked potentials].
    Ohira T; Toya S; Takase M; Nakamura Y; Miyazaki H; Nakatsukasa M; Ibata Y
    Neurol Med Chir (Tokyo); 1988 Aug; 28(8):772-8. PubMed ID: 2461524
    [No Abstract]   [Full Text] [Related]  

  • 23. Intraoperative brain-stem auditory evoked potentials during posterior fossa microvascular decompression.
    Friedman WA; Kaplan BJ; Gravenstein D; Rhoton AL
    J Neurosurg; 1985 Apr; 62(4):552-7. PubMed ID: 3973725
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Brainstem auditory evoked potential abnormalities in vascular malformations of the posterior fossa.
    Buettner UW; Stöhr M; Koletzki E
    J Neurol; 1983; 229(4):247-54. PubMed ID: 6192226
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Combined monitoring of evoked potentials during microsurgery for lesions adjacent to the brainstem and intracranial aneurysms.
    Kang DZ; Wu ZY; Lan Q; Yu LH; Lin ZY; Wang CY; Lin YX
    Chin Med J (Engl); 2007 Sep; 120(18):1567-73. PubMed ID: 17908471
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Monitoring auditory evoked potentials during acoustic neuroma surgery. Insights into the mechanism of the hearing loss.
    Levine RA; Ojemann RG; Montgomery WW; McGaffigan PM
    Ann Otol Rhinol Laryngol; 1984; 93(2 Pt 1):116-23. PubMed ID: 6712085
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Emprical factors associated with Brainstem auditory evoked potential monitoring during microvascular decompression for hemifacial spasm and its correlation to hearing loss.
    Ying T; Thirumala P; Chang Y; Habeych M; Crammond D; Balzer J
    Acta Neurochir (Wien); 2014 Mar; 156(3):571-5. PubMed ID: 24306235
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Importance of intraoperative monitoring of ABR and compound action potential of the eighth cranial nerve during microvascular decompression surgery].
    Nishihara K; Hanakita J; Kinuta Y; Kondo A; Yamamoto Y; Nakatani H
    No Shinkei Geka; 1986 Mar; 14(4):509-18. PubMed ID: 3713977
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Failure to preserve hearing in acoustic neuroma surgery: experiences after introduction of MRI].
    Sekiya T; Iwabuchi T; Suzuki S; Hatayama T; Ishii M; Oda N
    No Shinkei Geka; 1989 Dec; 17(12):1111-7. PubMed ID: 2615893
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Hearing prognosis and intraoperative guidance of brainstem auditory evoked potential in microvascular decompression.
    Sindou M; Fobé JL; Ciriano D; Fischer C
    Laryngoscope; 1992 Jun; 102(6):678-82. PubMed ID: 1602916
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Intraoperative electrophysiological monitoring for hearing preservation in acoustic neurinoma surgery].
    Ohira T; Toya S; Shiobara R; Kanzaki J; Nakamura Y; Nakatukasa M; Ibata Y; Takase M
    No To Shinkei; 1988 Jun; 40(6):553-60. PubMed ID: 3224031
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Brainstem auditory evoked potential monitoring: when is change in wave V significant?
    James ML; Husain AM
    Neurology; 2005 Nov; 65(10):1551-5. PubMed ID: 16301480
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Normal brainstem auditory evoked potentials in adult hypothyroidism.
    Vanasse M; Fischer C; Berthezène F; Roux Y; Volman G; Mornex R
    Laryngoscope; 1989 Mar; 99(3):302-6. PubMed ID: 2918801
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Monitoring of intraoperative auditory brainstem responses.
    Miyamoto RT; Diefendorf AO; Renshaw JJ; Brown DD
    Entechnology; 1989 Sep; ():46, 48-9. PubMed ID: 2611004
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Incidence of intraoperative hearing loss during middle cranial fossa approach for repair of superior semicircular canal dehiscence.
    Johanis M; Yang I; Gopen Q
    J Clin Neurosci; 2018 Aug; 54():109-112. PubMed ID: 29908720
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A quantitative assessment of the brain stem auditory evoked response during intraoperative monitoring.
    Zappulla R; Greenblatt E; Kaye S; Malis L
    Neurosurgery; 1984 Aug; 15(2):186-91. PubMed ID: 6483136
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Intraoperative monitoring of brain-stem auditory evoked potentials.
    Grundy BL; Jannetta PJ; Procopio PT; Lina A; Boston JR; Doyle E
    J Neurosurg; 1982 Nov; 57(5):674-81. PubMed ID: 7131068
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Retrolabyrinthine vestibular neurectomy with simultaneous monitoring of eighth nerve and brain stem auditory evoked potentials.
    Silverstein H; McDaniel A; Wazen J; Norrell H
    Otolaryngol Head Neck Surg; 1985 Dec; 93(6):736-42. PubMed ID: 3937094
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Monitoring of auditory evoked potentials during neurosurgical operations.
    Møller AR
    Electroencephalogr Clin Neurophysiol Suppl; 1987; 39():227-30. PubMed ID: 3477432
    [No Abstract]   [Full Text] [Related]  

  • 40. Microvascular decompression for hemifacial spasm: how can we protect auditory function?
    Amagasaki K; Watanabe S; Naemura K; Nakaguchi H
    Br J Neurosurg; 2015 Jun; 29(3):347-52. PubMed ID: 25665598
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.