BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 29173614)

  • 1. Pregnancy After Transcatheter Pulmonary Valve Implantation.
    Kozicka U; Weroński K; Rużyłło W; Demkow M; Kowalski M; Śpiewak M; Piotrowicz E; Siudalska H; Hoffman P; Biernacka EK
    Can J Cardiol; 2017 Dec; 33(12):1737.e5-1737.e7. PubMed ID: 29173614
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Speckle-Tracking Echocardiographic Measures of Right Ventricular Function Correlate With Improvement in Exercise Function After Percutaneous Pulmonary Valve Implantation.
    Chowdhury SM; Hijazi ZM; Fahey JT; Rhodes JF; Kar S; Makkar R; Mullen M; Cao QL; Shirali GS
    J Am Soc Echocardiogr; 2015 Sep; 28(9):1036-44. PubMed ID: 26117295
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Immediate and long-term outcomes of percutaneous transcatheter pulmonary valve implantation.
    Fiszer R; Dryżek P; Szkutnik M; Góreczny S; Krawczuk A; Moll J; Moszura T; Pawlak S; Białkowski J
    Cardiol J; 2017; 24(6):604-611. PubMed ID: 28248409
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Early outcomes in patients undergoing transcatheter versus surgical pulmonary valve replacement.
    Steinberg ZL; Jones TK; Verrier E; Stout KK; Krieger EV; Karamlou T
    Heart; 2017 Sep; 103(18):1455-1460. PubMed ID: 28351873
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transcatheter pulmonary valve implantation in patients with right ventricular outflow tract dysfunction: early and mid-term results.
    Biernacka EK; Rużyłło W; Demkow M; Kowalski M; Śpiewak M; Piotrowski W; Kuśmierczyk M; Banaś S; Różanski J; Hoffman P
    J Invasive Cardiol; 2015 Jun; 27(6):E82-9. PubMed ID: 26028663
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Outcomes Following Melody Transcatheter Pulmonary Valve Implantation for Right Ventricular Outflow Tract Dysfunction in Repaired Congenital Heart Disease: First Reported Australian Single Centre Experience.
    Markham R; Challa A; Kyranis S; Nicolae M; Murdoch D; Savage M; Malpas T; Radford DJ; Hamilton-Craig C; Walters DL
    Heart Lung Circ; 2017 Oct; 26(10):1085-1093. PubMed ID: 28185817
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Recent advances in transcatheter pulmonary valve delivery.
    Ringewald JM
    Curr Opin Cardiol; 2016 Jan; 31(1):88-94. PubMed ID: 26599062
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Anesthesia for Percutaneous Pulmonary Valve Implantation: A Case Series.
    Arboleda Salazar R; Heggie J; Wolski P; Horlick E; Osten M; Meineri M
    Anesth Analg; 2018 Jul; 127(1):39-45. PubMed ID: 29543640
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of percutaneous pulmonary valve implantation on exercise capacity: Which group of patients benefits most from the intervention?
    Biernacka EK; Piotrowicz E; Fronczak A; Mazgaj M; Demkow M; Rużyłło W; Śpiewak M; Kowalski M; Piotrowicz R; Weroński K; Hoffman P
    Cardiol J; 2015; 22(3):343-50. PubMed ID: 25733320
    [TBL] [Abstract][Full Text] [Related]  

  • 10. SCAI/AATS/ACC/STS Operator and Institutional Requirements for Transcatheter Valve Repair and Replacement, Part III: Pulmonic Valve.
    Hijazi ZM; Ruiz CE; Zahn E; Ringel R; Aldea GS; Bacha EA; Bavaria J; Bolman RM; Cameron DE; Dean LS; Feldman T; Fullerton D; Horlick E; Mack MJ; Miller DC; Moon MR; Mukherjee D; Trento A; Tommaso CL
    J Am Coll Cardiol; 2015 Jun; 65(23):2556-63. PubMed ID: 25819263
    [No Abstract]   [Full Text] [Related]  

  • 11. One-year follow-up of the Melody transcatheter pulmonary valve multicenter post-approval study.
    Armstrong AK; Balzer DT; Cabalka AK; Gray RG; Javois AJ; Moore JW; Rome JJ; Turner DR; Zellers TM; Kreutzer J
    JACC Cardiovasc Interv; 2014 Nov; 7(11):1254-62. PubMed ID: 25459038
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Melody ® transcatheter pulmonary valve implantation: results from a French registry.
    Fraisse A; Aldebert P; Malekzadeh-Milani S; Thambo JB; Piéchaud JF; Aucoururier P; Chatelier G; Bonnet D; Iserin L; Bonello B; Assaidi A; Kammache I; Boudjemline Y
    Arch Cardiovasc Dis; 2014 Nov; 107(11):607-14. PubMed ID: 25453718
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cardiac Magnetic Resonance to Evaluate Percutaneous Pulmonary Valve Implantation in Children and Young Adults.
    Gonzalez de Alba C; Molina Berganza F; Brownlee J; Khan M; Adebo D
    Tex Heart Inst J; 2018 Apr; 45(2):63-69. PubMed ID: 29844737
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Patient Selection Process for the Harmony Transcatheter Pulmonary Valve Early Feasibility Study.
    Gillespie MJ; Benson LN; Bergersen L; Bacha EA; Cheatham SL; Crean AM; Eicken A; Ewert P; Geva T; Hellenbrand WE; Hor KN; Horlick EM; Jones TK; Mayer J; McHenry BT; Osten MD; Powell AJ; Zahn EM; Cheatham JP
    Am J Cardiol; 2017 Oct; 120(8):1387-1392. PubMed ID: 28823485
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of transcatheter pulmonary valve replacement on biventricular strain and synchrony assessed by cardiac magnetic resonance feature tracking.
    Harrild DM; Marcus E; Hasan B; Alexander ME; Powell AJ; Geva T; McElhinney DB
    Circ Cardiovasc Interv; 2013 Dec; 6(6):680-7. PubMed ID: 24300136
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cardiopulmonary exercise function among patients undergoing transcatheter pulmonary valve implantation in the US Melody valve investigational trial.
    Batra AS; McElhinney DB; Wang W; Zakheim R; Garofano RP; Daniels C; Yung D; Cooper DM; Rhodes J
    Am Heart J; 2012 Feb; 163(2):280-7. PubMed ID: 22305848
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transcatheter Pulmonary Valve Implantation Provides Effective Treatment.
    Cochrane A; d'Udekem Y; Cheung M
    Heart Lung Circ; 2017 Oct; 26(10):1004-1005. PubMed ID: 28867026
    [No Abstract]   [Full Text] [Related]  

  • 18. Hybrid transcatheter pulmonary valve replacement: Moving into the mainstream?
    McElhinney DB
    Catheter Cardiovasc Interv; 2016 Nov; 88(5):811-813. PubMed ID: 27865074
    [No Abstract]   [Full Text] [Related]  

  • 19. Pulmonary Valve Function Late After Ross Procedure in 443 Adult Patients.
    Fricke TA; Skillington PD; Shi WY; Buratto E; Wynne R; Larobina M; Grigg LE
    Ann Thorac Surg; 2020 Apr; 109(4):1127-1131. PubMed ID: 31518586
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A prospective 5-year study of exercise performance following Melody valve implant.
    Priromprintr B; Silka MJ; Rhodes J; Batra AS
    Am Heart J; 2019 Mar; 209():47-53. PubMed ID: 30682562
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.