BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

310 related articles for article (PubMed ID: 29173912)

  • 1. Generation of synthetic CT using multi-scale and dual-contrast patches for brain MRI-only external beam radiotherapy.
    Aouadi S; Vasic A; Paloor S; Torfeh T; McGarry M; Petric P; Riyas M; Hammoud R; Al-Hammadi N
    Phys Med; 2017 Oct; 42():174-184. PubMed ID: 29173912
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Feasibility of MRI-only treatment planning for proton therapy in brain and prostate cancers: Dose calculation accuracy in substitute CT images.
    Koivula L; Wee L; Korhonen J
    Med Phys; 2016 Aug; 43(8):4634. PubMed ID: 27487880
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessing the Dosimetric Accuracy of Magnetic Resonance-Generated Synthetic CT Images for Focal Brain VMAT Radiation Therapy.
    Paradis E; Cao Y; Lawrence TS; Tsien C; Feng M; Vineberg K; Balter JM
    Int J Radiat Oncol Biol Phys; 2015 Dec; 93(5):1154-61. PubMed ID: 26581151
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Generation of synthetic CT from CBCT using deep learning approaches for head and neck cancer patients.
    Aouadi S; Yoganathan SA; Torfeh T; Paloor S; Caparrotti P; Hammoud R; Al-Hammadi N
    Biomed Phys Eng Express; 2023 Aug; 9(5):. PubMed ID: 37489854
    [No Abstract]   [Full Text] [Related]  

  • 5. Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch-based three-dimensional convolutional neural network.
    Dinkla AM; Florkow MC; Maspero M; Savenije MHF; Zijlstra F; Doornaert PAH; van Stralen M; Philippens MEP; van den Berg CAT; Seevinck PR
    Med Phys; 2019 Sep; 46(9):4095-4104. PubMed ID: 31206701
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences.
    Dowling JA; Sun J; Pichler P; Rivest-Hénault D; Ghose S; Richardson H; Wratten C; Martin J; Arm J; Best L; Chandra SS; Fripp J; Menk FW; Greer PB
    Int J Radiat Oncol Biol Phys; 2015 Dec; 93(5):1144-53. PubMed ID: 26581150
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy.
    Maspero M; Savenije MHF; Dinkla AM; Seevinck PR; Intven MPW; Jurgenliemk-Schulz IM; Kerkmeijer LGW; van den Berg CAT
    Phys Med Biol; 2018 Sep; 63(18):185001. PubMed ID: 30109989
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Regression and statistical shape model based substitute CT generation for MRI alone external beam radiation therapy from standard clinical MRI sequences.
    Ghose S; Greer PB; Sun J; Pichler P; Rivest-Henault D; Mitra J; Richardson H; Wratten C; Martin J; Arm J; Best L; Dowling JA
    Phys Med Biol; 2017 Oct; 62(22):8566-8580. PubMed ID: 28976369
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluating the Hounsfield unit assignment and dose differences between CT-based standard and deep learning-based synthetic CT images for MRI-only radiation therapy of the head and neck.
    Singhrao K; Dugan CL; Calvin C; Pelayo L; Yom SS; Chan JW; Scholey JE; Singer L
    J Appl Clin Med Phys; 2024 Jan; 25(1):e14239. PubMed ID: 38128040
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tissue segmentation-based electron density mapping for MR-only radiotherapy treatment planning of brain using conventional T1-weighted MR images.
    Yu H; Oliver M; Leszczynski K; Lee Y; Karam I; Sahgal A
    J Appl Clin Med Phys; 2019 Aug; 20(8):11-20. PubMed ID: 31257709
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cone beam CT for QA of synthetic CT in MRI only for prostate patients.
    Palmér E; Persson E; Ambolt P; Gustafsson C; Gunnlaugsson A; Olsson LE
    J Appl Clin Med Phys; 2018 Nov; 19(6):44-52. PubMed ID: 30182461
    [TBL] [Abstract][Full Text] [Related]  

  • 12. MRI-only brain radiotherapy: Assessing the dosimetric accuracy of synthetic CT images generated using a deep learning approach.
    Kazemifar S; McGuire S; Timmerman R; Wardak Z; Nguyen D; Park Y; Jiang S; Owrangi A
    Radiother Oncol; 2019 Jul; 136():56-63. PubMed ID: 31015130
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Monte Carlo Dose Calculation Using MRI Based Synthetic CT Generated by Fully Convolutional Neural Network for Gamma Knife Radiosurgery.
    Yuan J; Fredman E; Jin JY; Choi S; Mansur D; Sloan A; Machtay M; Zheng Y
    Technol Cancer Res Treat; 2021; 20():15330338211046433. PubMed ID: 34632872
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Deep Convolution Neural Network (DCNN) Multiplane Approach to Synthetic CT Generation From MR images-Application in Brain Proton Therapy.
    Spadea MF; Pileggi G; Zaffino P; Salome P; Catana C; Izquierdo-Garcia D; Amato F; Seco J
    Int J Radiat Oncol Biol Phys; 2019 Nov; 105(3):495-503. PubMed ID: 31271823
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Technique to Rapidly Generate Synthetic Computed Tomography for Magnetic Resonance Imaging-Guided Online Adaptive Replanning: An Exploratory Study.
    Ahunbay EE; Thapa R; Chen X; Paulson E; Li XA
    Int J Radiat Oncol Biol Phys; 2019 Apr; 103(5):1261-1270. PubMed ID: 30550817
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dosimetric evaluation of an atlas-based synthetic CT generation approach for MR-only radiotherapy of pelvis anatomy.
    Farjam R; Tyagi N; Deasy JO; Hunt MA
    J Appl Clin Med Phys; 2019 Jan; 20(1):101-109. PubMed ID: 30474353
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Identification and separation of rigid image registration error sources, demonstrated for MRI-only image guided radiotherapy.
    Tyyger M; Nix M; Al-Qaisieh B; Teo MT; Speight R
    Biomed Phys Eng Express; 2020 Apr; 6(3):035032. PubMed ID: 33438677
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical validation of a commercially available deep learning software for synthetic CT generation for brain.
    Lerner M; Medin J; Jamtheim Gustafsson C; Alkner S; Siversson C; Olsson LE
    Radiat Oncol; 2021 Apr; 16(1):66. PubMed ID: 33827619
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Atlas-guided generation of pseudo-CT images for MRI-only and hybrid PET-MRI-guided radiotherapy treatment planning.
    Arabi H; Koutsouvelis N; Rouzaud M; Miralbell R; Zaidi H
    Phys Med Biol; 2016 Sep; 61(17):6531-52. PubMed ID: 27524504
    [TBL] [Abstract][Full Text] [Related]  

  • 20. MRI-based treatment planning for proton radiotherapy: dosimetric validation of a deep learning-based liver synthetic CT generation method.
    Liu Y; Lei Y; Wang Y; Wang T; Ren L; Lin L; McDonald M; Curran WJ; Liu T; Zhou J; Yang X
    Phys Med Biol; 2019 Jul; 64(14):145015. PubMed ID: 31146267
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.