BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

547 related articles for article (PubMed ID: 29176052)

  • 1. Development of a dual-ended readout detector with segmented crystal bars made using a subsurface laser engraving technique.
    Mohammadi A; Yoshida E; Nishikido F; Nitta M; Shimizu K; Sakai T; Yamaya T
    Phys Med Biol; 2018 Jan; 63(2):025019. PubMed ID: 29176052
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of dual-ended depth-of-interaction detectors using laser-induced crystals for small animal PET systems.
    Mohammadi A; Inadama N; Nishikido F; Yamaya T
    Phys Med Biol; 2021 Sep; 66(17):. PubMed ID: 34325418
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intrinsic spatial resolution evaluation of the X'tal cube PET detector based on a 3D crystal block segmented by laser processing.
    Yoshida E; Tashima H; Inadama N; Nishikido F; Moriya T; Omura T; Watanabe M; Murayama H; Yamaya T
    Radiol Phys Technol; 2013 Jan; 6(1):21-7. PubMed ID: 22782296
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel single-ended readout depth-of-interaction PET detector fabricated using sub-surface laser engraving.
    Uchida H; Sakai T; Yamauchi H; Hakamata K; Shimizu K; Yamashita T
    Phys Med Biol; 2016 Sep; 61(18):6635-6650. PubMed ID: 27541440
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Potential for reducing the numbers of SiPM readout surfaces of laser-processed X'tal cube PET detectors.
    Hirano Y; Inadama N; Yoshida E; Nishikido F; Murayama H; Watanabe M; Yamaya T
    Phys Med Biol; 2013 Mar; 58(5):1361-74. PubMed ID: 23391640
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of depth encoding small animal PET detectors using dual-ended readout of pixelated scintillator arrays with SiPMs.
    Kuang Z; Sang Z; Wang X; Fu X; Ren N; Zhang X; Zheng Y; Yang Q; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2018 Feb; 45(2):613-621. PubMed ID: 29222959
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance of long rectangular semi-monolithic scintillator PET detectors.
    Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A SiPM-based isotropic-3D PET detector X'tal cube with a three-dimensional array of 1 mm(3) crystals.
    Yamaya T; Mitsuhashi T; Matsumoto T; Inadama N; Nishikido F; Yoshida E; Murayama H; Kawai H; Suga M; Watanabe M
    Phys Med Biol; 2011 Nov; 56(21):6793-807. PubMed ID: 21971079
    [TBL] [Abstract][Full Text] [Related]  

  • 9. GPU-based optical propagation simulator of a laser-processed crystal block for the X'tal cube PET detector.
    Ogata Y; Ohnishi T; Moriya T; Inadama N; Nishikido F; Yoshida E; Murayama H; Yamaya T; Haneishi H
    Radiol Phys Technol; 2014 Jan; 7(1):35-42. PubMed ID: 23896989
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Depth-of-interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual-ended signal readout.
    Seo M; Park H; Lee S; Ko GB; Lee JS
    Med Phys; 2023 Jul; 50(7):4112-4121. PubMed ID: 36907664
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An edge-readout, multilayer detector for positron emission tomography.
    Li X; Ruiz-Gonzalez M; Furenlid LR
    Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A thick semi-monolithic scintillator detector for clinical PET scanners.
    Zhang C; Wang X; Sun M; Kuang Z; Zhang X; Ren N; Wu S; Sang Z; Sun T; Hu Z; Yang Y; Liu Z
    Phys Med Biol; 2021 Mar; 66(6):065023. PubMed ID: 33709958
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simulation study optimizing the number of photodetection faces for the X'tal cube PET detector with separated crystal segments.
    Matsumoto T; Yamaya T; Yoshida E; Nishikido F; Inadama N; Murayama H; Suga M
    Radiol Phys Technol; 2014 Jan; 7(1):43-50. PubMed ID: 23928910
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Depth-of-interaction measurement in a single-layer crystal array with a single-ended readout using digital silicon photomultiplier.
    Lee MS; Lee JS
    Phys Med Biol; 2015 Aug; 60(16):6495-514. PubMed ID: 26247294
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A depth-of-interaction PET detector using a stair-shaped reflector arrangement and a single-ended scintillation light readout.
    Son JW; Lee MS; Lee JS
    Phys Med Biol; 2017 Jan; 62(2):465-483. PubMed ID: 28000613
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel depth-of-interaction block detector for positron emission tomography using a dichotomous orthogonal symmetry decoding concept.
    Zhang Y; Yan H; Baghaei H; Wong WH
    Phys Med Biol; 2016 Feb; 61(4):1608-33. PubMed ID: 26836144
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A layered single-side readout depth of interaction time-of-flight-PET detector.
    Bläckberg L; Sajedi S; El Fakhri G; Sabet H
    Phys Med Biol; 2021 Feb; 66(4):045025. PubMed ID: 33570050
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Depth-encoding using optical photon TOF in a prism-PET detector with tapered crystals.
    Zeng X; LaBella A; Wang Z; Li Y; Tan W; Goldan AH
    Med Phys; 2024 Jun; 51(6):4044-4055. PubMed ID: 38682574
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET.
    Yeom JY; Vinke R; Levin CS
    Med Phys; 2014 Dec; 41(12):122501. PubMed ID: 25471979
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel method to calibrate DOI function of a PET detector with a dual-ended-scintillator readout.
    Shao Y; Yao R; Ma T
    Med Phys; 2008 Dec; 35(12):5829-40. PubMed ID: 19175139
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 28.