BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

227 related articles for article (PubMed ID: 29176330)

  • 1. Dissipation of energy during the respiratory cycle: conditional importance of ergotrauma to structural lung damage.
    Marini JJ
    Curr Opin Crit Care; 2018 Feb; 24(1):16-22. PubMed ID: 29176330
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Increasing the inspiratory time and I:E ratio during mechanical ventilation aggravates ventilator-induced lung injury in mice.
    Müller-Redetzky HC; Felten M; Hellwig K; Wienhold SM; Naujoks J; Opitz B; Kershaw O; Gruber AD; Suttorp N; Witzenrath M
    Crit Care; 2015 Jan; 19(1):23. PubMed ID: 25888164
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ventilator-induced lung injury during controlled ventilation in patients with acute respiratory distress syndrome: less is probably better.
    Cruz FF; Ball L; Rocco PRM; Pelosi P
    Expert Rev Respir Med; 2018 May; 12(5):403-414. PubMed ID: 29575957
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Research status of mechanical power in ventilator-induced lung injury].
    Sun X; Wang Y; Yang Y; Zhou J
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2019 Dec; 31(12):1549-1551. PubMed ID: 32029049
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ventilator-induced lung injury: the anatomical and physiological framework.
    Gattinoni L; Protti A; Caironi P; Carlesso E
    Crit Care Med; 2010 Oct; 38(10 Suppl):S539-48. PubMed ID: 21164395
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Physiology in Medicine: Understanding dynamic alveolar physiology to minimize ventilator-induced lung injury.
    Nieman GF; Satalin J; Kollisch-Singule M; Andrews P; Aiash H; Habashi NM; Gatto LA
    J Appl Physiol (1985); 2017 Jun; 122(6):1516-1522. PubMed ID: 28385915
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The future of mechanical ventilation: lessons from the present and the past.
    Gattinoni L; Marini JJ; Collino F; Maiolo G; Rapetti F; Tonetti T; Vasques F; Quintel M
    Crit Care; 2017 Jul; 21(1):183. PubMed ID: 28701178
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical Power: A New Concept in Mechanical Ventilation.
    Paudel R; Trinkle CA; Waters CM; Robinson LE; Cassity E; Sturgill JL; Broaddus R; Morris PE
    Am J Med Sci; 2021 Dec; 362(6):537-545. PubMed ID: 34597688
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Minimisation of dissipated energy in the airways during mechanical ventilation by using constant inspiratory and expiratory flows - Flow-controlled ventilation (FCV).
    Barnes T; van Asseldonk D; Enk D
    Med Hypotheses; 2018 Dec; 121():167-176. PubMed ID: 30396474
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantifying unintended exposure to high tidal volumes from breath stacking dyssynchrony in ARDS: the BREATHE criteria.
    Beitler JR; Sands SA; Loring SH; Owens RL; Malhotra A; Spragg RG; Matthay MA; Thompson BT; Talmor D
    Intensive Care Med; 2016 Sep; 42(9):1427-36. PubMed ID: 27342819
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Should we use driving pressure to set tidal volume?
    Grieco DL; Chen L; Dres M; Brochard L
    Curr Opin Crit Care; 2017 Feb; 23(1):38-44. PubMed ID: 27875410
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mid-frequency ventilation: unconventional use of conventional mechanical ventilation as a lung-protection strategy.
    Mireles-Cabodevila E; Chatburn RL
    Respir Care; 2008 Dec; 53(12):1669-77. PubMed ID: 19025701
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determinants and Prevention of Ventilator-Induced Lung Injury.
    Vasques F; Duscio E; Cipulli F; Romitti F; Quintel M; Gattinoni L
    Crit Care Clin; 2018 Jul; 34(3):343-356. PubMed ID: 29907269
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Practical assessment of risk of VILI from ventilating power: a conceptual model.
    Marini JJ; Thornton LT; Rocco PRM; Gattinoni L; Crooke PS
    Crit Care; 2023 Apr; 27(1):157. PubMed ID: 37081517
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Using injury cost functions from a predictive single-compartment model to assess the severity of mechanical ventilator-induced lung injuries.
    Mellenthin MM; Seong SA; Roy GS; Bartolák-Suki E; Hamlington KL; Bates JHT; Smith BJ
    J Appl Physiol (1985); 2019 Jul; 127(1):58-70. PubMed ID: 31046518
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The basics on mechanical ventilation support in acute respiratory distress syndrome].
    Tomicic V; Fuentealba A; Martínez E; Graf J; Batista Borges J
    Med Intensiva; 2010; 34(6):418-27. PubMed ID: 20097448
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Does the use of high PEEP levels prevent ventilator-induced lung injury?
    Bugedo G; Retamal J; Bruhn A
    Rev Bras Ter Intensiva; 2017; 29(2):231-237. PubMed ID: 28977263
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Energy dissipation during expiration and ventilator-induced lung injury: an experimental animal study.
    Busana M; Zinnato C; Romitti F; Palumbo M; Gattarello S; Sonzogni A; Gersmann AK; Richter A; Herrmann P; Hahn G; Brusatori S; Maj R; Velati M; Moerer O; Meissner K; Barnes T; Quintel M; Marini JJ; Gattinoni L
    J Appl Physiol (1985); 2022 Nov; 133(5):1212-1219. PubMed ID: 36173324
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Will all ARDS patients be receiving mechanical ventilation in 2035? Yes.
    Martin-Loeches I; Bos LD; Goligher EC
    Intensive Care Med; 2017 Apr; 43(4):568-569. PubMed ID: 27515160
    [No Abstract]   [Full Text] [Related]  

  • 20. Evolving concepts for safer ventilation.
    Marini JJ
    Crit Care; 2019 Jun; 23(Suppl 1):114. PubMed ID: 31200734
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.