These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

68 related articles for article (PubMed ID: 2917870)

  • 1. Comment on 'Marble attenuation characteristics for diagnostic x rays'.
    Gomaa MA
    Health Phys; 1989 Mar; 56(3):377. PubMed ID: 2917870
    [No Abstract]   [Full Text] [Related]  

  • 2. Marble attenuation characteristics for diagnostic x rays.
    Abdul-Majid S
    Health Phys; 1987 Mar; 52(3):385-7. PubMed ID: 3818308
    [No Abstract]   [Full Text] [Related]  

  • 3. Investigation of photon attenuation coefficients for marble.
    Basyigit C; Akkurt I; Kilincarslan S; Akkurt A
    J Radiol Prot; 2005 Jun; 25(2):189-92. PubMed ID: 15942062
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Attenuation characteristics of gypsum wallboard.
    Christensen RC; Sayeg JA
    Health Phys; 1979 May; 36(5):595-600. PubMed ID: 114505
    [No Abstract]   [Full Text] [Related]  

  • 5. Neutron cross sections for the Egyptian marble.
    Gomaa MA; el-Shinawy RM; Mohamed HO
    Health Phys; 1973 Aug; 25(2):175-6. PubMed ID: 4784250
    [No Abstract]   [Full Text] [Related]  

  • 6. Tenth value layers for 60Co gamma rays and for 4, 6, 10, 15, and 18 MV x rays in concrete for beams of cone angles between 0 degrees and 14 degrees calculated by Monte Carlo simulation.
    Jaradat AK; Biggs PJ
    Health Phys; 2007 May; 92(5):456-63. PubMed ID: 17429304
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The diagnostic X-ray protection characteristics of Ytong, an aerated concrete based building material.
    Tsalafoutas IA; Yakoumakis E; Manetou A; Flioni-Vyza A
    Br J Radiol; 1998 Sep; 71(849):944-9. PubMed ID: 10195009
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Attenuation characteristics of MagnaDense high-density concrete at 6, 10 and 15 mv for use in radiotherapy bunker design.
    Jones MR; Peet DJ; Horton PW
    Health Phys; 2009 Jan; 96(1):67-75. PubMed ID: 19066488
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comment on the rap, a proposed unit for diagnostic x-ray protection.
    Burlin TE; Wheatley BM
    Health Phys; 1973 Jan; 24(1):113. PubMed ID: 4682431
    [No Abstract]   [Full Text] [Related]  

  • 10. [The study of X & gamma rays' co-character imaging and its value].
    Pan LD
    Zhongguo Yi Liao Qi Xie Za Zhi; 2000 Sep; 24(5):276-8. PubMed ID: 12583023
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiation protection guidance to federal agencies for diagnostic x rays: approval of recommendations.
    Fed Regist; 1978 Feb; 43(22):4375-80. PubMed ID: 10306555
    [No Abstract]   [Full Text] [Related]  

  • 12. A proposed unit for patient radiation exposure from diagnostic x-rays.
    Health Phys; 1973 Apr; 24(4):445-6. PubMed ID: 4698195
    [No Abstract]   [Full Text] [Related]  

  • 13. Variations in x-ray barrier efficiency of some commonly used building materials.
    MOOS WS; HAAS RE; YALE SH; HAUPTFUEHRER JD
    Oral Surg Oral Med Oral Pathol; 1961 May; 14():569-73. PubMed ID: 13772382
    [No Abstract]   [Full Text] [Related]  

  • 14. Broad beam attenuation in Leca for 50-140 kVp x-rays.
    Wøhni T
    Health Phys; 1981 Feb; 40(2):205-9. PubMed ID: 7216798
    [No Abstract]   [Full Text] [Related]  

  • 15. Comments on 'Diagnostic X-ray shielding design based on the empirical model of photon attenuation'.
    Rummerfield PS
    Health Phys; 1984 Apr; 46(4):958-61. PubMed ID: 6706607
    [No Abstract]   [Full Text] [Related]  

  • 16. [Dispersion of x-ray radiation on building materials and radiation exposure of the physician in x-ray rooms].
    Göttel K; Kraft A
    Fortschr Geb Rontgenstr Nuklearmed; 1971 Oct; 115(4):522-7. PubMed ID: 4398999
    [No Abstract]   [Full Text] [Related]  

  • 17. Phantom organ shielding factors for radiation from walls of buildings.
    Koblinger L
    Health Phys; 1981 Feb; 40(2):243-5. PubMed ID: 7216805
    [No Abstract]   [Full Text] [Related]  

  • 18. Design of an x-ray room for a dental practice.
    Noffke CE; Snyman AM; Smit E; Chabikuli CE
    SADJ; 2006 Aug; 61(7):292-4, 296. PubMed ID: 17133790
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Test of protective materials for diagnostic X-ray (author's transl)].
    Wang XM
    Zhonghua Fang She Xue Za Zhi; 1980 Nov; 14(4):308-11. PubMed ID: 6454565
    [No Abstract]   [Full Text] [Related]  

  • 20. Barytes Board: a cost effective radiation barrier material for use in diagnostic X-ray suites.
    Coalter GC; Metcalfe PE
    Australas Radiol; 1987 Feb; 31(1):90-2. PubMed ID: 3619816
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 4.