These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 29181721)

  • 1. On the Failure Initiation in the Proximal Human Femur Under Simulated Sideways Fall.
    Bahaloo H; Enns-Bray WS; Fleps I; Ariza O; Gilchrist S; Soyka RW; Guy P; Palsson H; Ferguson SJ; Cripton PA; Helgason B
    Ann Biomed Eng; 2018 Feb; 46(2):270-283. PubMed ID: 29181721
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of non-invasive assessments of strength of the proximal femur.
    Johannesdottir F; Thrall E; Muller J; Keaveny TM; Kopperdahl DL; Bouxsein ML
    Bone; 2017 Dec; 105():93-102. PubMed ID: 28739416
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Relationships between femoral strength evaluated by nonlinear finite element analysis and BMD, material distribution and geometric morphology.
    Gong H; Zhang M; Fan Y; Kwok WL; Leung PC
    Ann Biomed Eng; 2012 Jul; 40(7):1575-85. PubMed ID: 22258889
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biofidelic finite element models for accurately classifying hip fracture in a retrospective clinical study of elderly women from the AGES Reykjavik cohort.
    Enns-Bray WS; Bahaloo H; Fleps I; Pauchard Y; Taghizadeh E; Sigurdsson S; Aspelund T; Büchler P; Harris T; Gudnason V; Ferguson SJ; Pálsson H; Helgason B
    Bone; 2019 Mar; 120():25-37. PubMed ID: 30240961
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microstructural failure mechanisms in the human proximal femur for sideways fall loading.
    Nawathe S; Akhlaghpour H; Bouxsein ML; Keaveny TM
    J Bone Miner Res; 2014 Feb; 29(2):507-15. PubMed ID: 23832419
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Contribution of trochanteric soft tissues to fall force estimates, the factor of risk, and prediction of hip fracture risk.
    Bouxsein ML; Szulc P; Munoz F; Thrall E; Sornay-Rendu E; Delmas PD
    J Bone Miner Res; 2007 Jun; 22(6):825-31. PubMed ID: 17352651
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hip fracture and anthropometric variations: dominance among trochanteric soft tissue thickness, body height and body weight during sideways fall.
    Majumder S; Roychowdhury A; Pal S
    Clin Biomech (Bristol, Avon); 2013; 28(9-10):1034-40. PubMed ID: 24139746
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Femoral strength and strains in sideways fall: Validation of finite element models against bilateral strain measurements.
    Kok J; Grassi L; Gustafsson A; Isaksson H
    J Biomech; 2021 Jun; 122():110445. PubMed ID: 33933857
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Study of stress variations in single-stance and sideways fall using image-based finite element analysis.
    Faisal TR; Luo Y
    Biomed Mater Eng; 2016 May; 27(1):1-14. PubMed ID: 27175463
    [TBL] [Abstract][Full Text] [Related]  

  • 10. QCT of the proximal femur--which parameters should be measured to discriminate hip fracture?
    Museyko O; Bousson V; Adams J; Laredo J-; Engelke K
    Osteoporos Int; 2016 Mar; 27(3):1137-1147. PubMed ID: 26415934
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simulation of hip fracture in sideways fall using a 3D finite element model of pelvis-femur-soft tissue complex with simplified representation of whole body.
    Majumder S; Roychowdhury A; Pal S
    Med Eng Phys; 2007 Dec; 29(10):1167-78. PubMed ID: 17270483
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sensitivity of proximal femoral stiffness and areal bone mineral density to changes in bone geometry and density.
    Pisharody S; Phillips R; Langton CM
    Proc Inst Mech Eng H; 2008 Apr; 222(3):367-75. PubMed ID: 18491705
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vivo discrimination of hip fracture with quantitative computed tomography: results from the prospective European Femur Fracture Study (EFFECT).
    Bousson VD; Adams J; Engelke K; Aout M; Cohen-Solal M; Bergot C; Haguenauer D; Goldberg D; Champion K; Aksouh R; Vicaut E; Laredo JD
    J Bone Miner Res; 2011 Apr; 26(4):881-93. PubMed ID: 20939025
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Robust QCT/FEA models of proximal femur stiffness and fracture load during a sideways fall on the hip.
    Dragomir-Daescu D; Op Den Buijs J; McEligot S; Dai Y; Entwistle RC; Salas C; Melton LJ; Bennet KE; Khosla S; Amin S
    Ann Biomed Eng; 2011 Feb; 39(2):742-55. PubMed ID: 21052839
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact loading history modulates hip fracture load and location: A finite element simulation study of the proximal femur in female athletes.
    Abe S; Narra N; Nikander R; Hyttinen J; Kouhia R; Sievänen H
    J Biomech; 2018 Jul; 76():136-143. PubMed ID: 29921524
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Study of sex differences in the association between hip fracture risk and body parameters by DXA-based biomechanical modeling.
    Nasiri M; Luo Y
    Bone; 2016 Sep; 90():90-8. PubMed ID: 27292653
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In Vivo Assessment of Age- and Loading Configuration-Related Changes in Multiscale Mechanical Behavior of the Human Proximal Femur Using MRI-Based Finite Element Analysis.
    Zhang L; Wang L; Fu R; Wang J; Yang D; Liu Y; Zhang W; Liang W; Yang R; Yang H; Cheng X
    J Magn Reson Imaging; 2021 Mar; 53(3):905-912. PubMed ID: 33075178
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prediction of Hip Failure Load: In Vitro Study of 80 Femurs Using Three Imaging Methods and Finite Element Models-The European Fracture Study (EFFECT).
    Pottecher P; Engelke K; Duchemin L; Museyko O; Moser T; Mitton D; Vicaut E; Adams J; Skalli W; Laredo JD; Bousson V
    Radiology; 2016 Sep; 280(3):837-47. PubMed ID: 27077380
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determinants of fracture type in the proximal femur: Biomechanical study of fresh frozen cadavers and finite element models.
    Yano S; Matsuura Y; Hagiwara S; Nakamura J; Kawarai Y; Suzuki T; Kanno K; Shoda J; Tsurumi Y; Ohtori S
    Bone; 2022 May; 158():116352. PubMed ID: 35181576
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of Hip Fracture Risk Using Cross-Section Strain Energy Determined by QCT-Based Finite Element Modeling.
    Kheirollahi H; Luo Y
    Biomed Res Int; 2015; 2015():413839. PubMed ID: 26601105
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.