These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
195 related articles for article (PubMed ID: 29185181)
1. Efficacy and safety of transcatheter aortic valve implantation with Edwards SAPIEN 3 and XT in smaller Asian anatomy. Nakashima M; Watanabe Y; Hioki H; Nara Y; Nagura F; Hosogoe N; Kawashima H; Kataoka A; Otsuki S; Konno K; Kyono H; Yokoyama N; Kozuma K Cardiovasc Interv Ther; 2018 Oct; 33(4):384-390. PubMed ID: 29185181 [TBL] [Abstract][Full Text] [Related]
2. Incidence and predictors of prosthesis-patient mismatch after TAVI using SAPIEN 3 in Asian: differences between the newer and older balloon-expandable valve. Miyasaka M; Tada N; Taguri M; Kato S; Enta Y; Hata M; Watanabe Y; Naganuma T; Yamawaki M; Yamanaka F; Shirai S; Ueno H; Mizutani K; Tabata M; Takagi K; Yamamoto M; Hayashida K; Open Heart; 2021 Mar; 8(1):. PubMed ID: 33737333 [TBL] [Abstract][Full Text] [Related]
3. Comparison of Edwards SAPIEN 3 versus SAPIEN XT in transfemoral transcatheter aortic valve implantation: Difference of valve selection in the real world. Arai T; Lefèvre T; Hovasse T; Morice MC; Garot P; Benamer H; Unterseeh T; Hayashida K; Watanabe Y; Bouvier E; Cormier B; Chevalier B J Cardiol; 2017 Mar; 69(3):565-569. PubMed ID: 27288330 [TBL] [Abstract][Full Text] [Related]
4. Outcomes of transfemoral balloon expandable transcatheter aortic valve implantation: Comparison of two subsequent valve generations. Schymik G; Wendler O; Hengstenberg C; Ohlmann P; Gilard M; Digne F; Souteyrand G; Letocart V; van Belle E; Bramlage P; Tarantini G; Catheter Cardiovasc Interv; 2020 Oct; 96(4):930-939. PubMed ID: 31794159 [TBL] [Abstract][Full Text] [Related]
5. Procedural Results and Clinical Outcomes of Transcatheter Aortic Valve Implantation in Switzerland: An Observational Cohort Study of Sapien 3 Versus Sapien XT Transcatheter Heart Valves. Binder RK; Stortecky S; Heg D; Tueller D; Jeger R; Toggweiler S; Pedrazzini G; Amann FW; Ferrari E; Noble S; Nietlispach F; Maisano F; Räber L; Roffi M; Grünenfelder J; Jüni P; Huber C; Windecker S; Wenaweser P Circ Cardiovasc Interv; 2015 Oct; 8(10):. PubMed ID: 26453687 [TBL] [Abstract][Full Text] [Related]
6. Transfemoral aortic valve implantation is more successful with the Edwards Sapien 3 compared with the Edwards XT for the treatment of symptomatic severe aortic stenosis. Gonska B; Seeger J; Junker A; Rodewald C; Trepte U; Scharnbeck D; Rottbauer W; Wöhrle J Arch Cardiovasc Dis; 2018; 111(8-9):470-479. PubMed ID: 29128473 [TBL] [Abstract][Full Text] [Related]
7. Comparison of 1-Year Survival and Frequency of Paravalvular Leakage Using the Sapien 3 Versus the Sapien XT for Transcatheter Aortic Valve Implantation for Aortic Stenosis. Meyer A; Unbehaun A; Hamandi M; Sündermann SH; Buz S; Klein C; Stamm C; Falk V; Kempfert J Am J Cardiol; 2017 Dec; 120(12):2247-2255. PubMed ID: 29103606 [TBL] [Abstract][Full Text] [Related]
8. Transaortic transcatheter aortic valve implantation using SAPIEN XT or SAPIEN 3 valves in the ROUTE registry. Romano M; Frank D; Cocchieri R; Jagielak D; Bonaros N; Aiello M; Lapeze J; Laine M; Chocron S; Muir D; Eichinger W; Thielmann M; Labrousse L; Arne Rein K; Verhoye JP; Gerosa G; Baumbach H; Deutsch C; Bramlage P; Thoenes M; Bapat V Interact Cardiovasc Thorac Surg; 2017 Nov; 25(5):757-764. PubMed ID: 28582580 [TBL] [Abstract][Full Text] [Related]
9. Prospective analysis of 30-day safety and performance of transfemoral transcatheter aortic valve implantation with Edwards SAPIEN XT versus SAPIEN prostheses. Eltchaninoff H; Durand E; Borz B; Godin M; Tron C; Litzler PY; Bessou JP; Bejar K; Fraccaro C; Sanchez-Giron C; Dacher JN; Bauer F; Cribier A Arch Cardiovasc Dis; 2012 Mar; 105(3):132-40. PubMed ID: 22520795 [TBL] [Abstract][Full Text] [Related]
10. Transcatheter aortic valve implantation with the new balloon-expandable Sapien 3 versus Sapien XT valve system: a propensity score-matched single-center comparison. Nijhoff F; Abawi M; Agostoni P; Ramjankhan FZ; Doevendans PA; Stella PR Circ Cardiovasc Interv; 2015 Jun; 8(6):e002408. PubMed ID: 26033967 [TBL] [Abstract][Full Text] [Related]
12. Self-expanding Portico Valve Versus Balloon-expandable SAPIEN XT Valve in Patients With Small Aortic Annuli: Comparison of Hemodynamic Performance. Del Trigo M; Dahou A; Webb JG; Dvir D; Puri R; Abdul-Jawad Altisent O; Campelo-Parada F; Thompson C; Leipsic J; Stub D; DeLarochellière R; Paradis JM; Dumont E; Doyle D; Mohammadi S; Pasian S; Côté M; Pibarot P; Rodés-Cabau J Rev Esp Cardiol (Engl Ed); 2016 May; 69(5):501-8. PubMed ID: 26739827 [TBL] [Abstract][Full Text] [Related]
13. New generation devices for transfemoral transcatheter aortic valve replacement are superior compared with last generation devices with respect to VARC-2 outcome. Seeger J; Gonska B; Rottbauer W; Wöhrle J Cardiovasc Interv Ther; 2018 Jul; 33(3):247-255. PubMed ID: 28643214 [TBL] [Abstract][Full Text] [Related]
14. Direct transfemoral transcatheter aortic valve implantation without balloon pre-dilatation using the Edwards Sapien XT valve. Bandali A; Parry-Williams G; Kassam A; Palmer S; Williams PD; de Belder MA; Owens A; Goodwin A; Muir DF Catheter Cardiovasc Interv; 2016 Nov; 88(6):978-985. PubMed ID: 27189391 [TBL] [Abstract][Full Text] [Related]
15. Early versus newer generation transcatheter heart valves for transcatheter aortic valve implantation: Echocardiographic and hemodynamic evaluation of an all-comers study cohort using the dimensionless aortic regurgitation index (AR-index). Stundl A; Lucht H; Shamekhi J; Weber M; Sedaghat A; Mellert F; Grube E; Nickenig G; Werner N; Sinning JM PLoS One; 2019; 14(5):e0217544. PubMed ID: 31150455 [TBL] [Abstract][Full Text] [Related]
16. Bioprosthetic Valve Performance After Transcatheter Aortic Valve Replacement With Self-Expanding Versus Balloon-Expandable Valves in Large Versus Small Aortic Valve Annuli: Insights From the CHOICE Trial and the CHOICE-Extend Registry. Abdelghani M; Mankerious N; Allali A; Landt M; Kaur J; Sulimov DS; Merten C; Sachse S; Mehilli J; Neumann FJ; Frerker C; Kurz T; El-Mawardy M; Richardt G; Abdel-Wahab M JACC Cardiovasc Interv; 2018 Dec; 11(24):2507-2518. PubMed ID: 30503595 [TBL] [Abstract][Full Text] [Related]
17. Clinical outcomes of self-expandable vs. balloon-expandable TAVI for severe aortic stenosis. Tham JLM; Adams H; Paleri S; Wright C; Dimitriou J; Newcomb A; MacIsaac AI; Whitbourn RJ; Palmer SC Acta Cardiol; 2020 Jun; 75(3):218-225. PubMed ID: 30931804 [No Abstract] [Full Text] [Related]