198 related articles for article (PubMed ID: 29201305)
1. Biomechanical Comparison Study of Three Fixation Methods for Proximal Chevron Osteotomy of the First Metatarsal in Hallux Valgus.
Kim JS; Cho HK; Young KW; Kim JS; Lee KT
Clin Orthop Surg; 2017 Dec; 9(4):514-520. PubMed ID: 29201305
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical analysis of two fixation methods for proximal chevron osteotomy of the first metatarsal.
Schuh R; Hofstaetter JG; Benca E; Willegger M; von Skrbensky G; Zandieh S; Wanivenhaus A; Holinka J; Windhager R
Int Orthop; 2014 May; 38(5):983-9. PubMed ID: 24492997
[TBL] [Abstract][Full Text] [Related]
3. Biomechanical comparison of hallux valgus correction using the proximal chevron osteotomy fixed with a medial locking plate and the Ludloff osteotomy fixed with two screws.
Scott AT; DeOrio JK; Montijo HE; Glisson RR
Clin Biomech (Bristol, Avon); 2010 Mar; 25(3):271-6. PubMed ID: 20060627
[TBL] [Abstract][Full Text] [Related]
4. Biomechanical evaluation of the proximal chevron osteotomy in comparison to the Lapidus arthrodesis for the correction of hallux valgus deformities.
Kasparek MF; Benca E; Hirtler L; Willegger M; Boettner F; Zandieh S; Holinka J; Windhager R; Schuh R
Int Orthop; 2022 Oct; 46(10):2257-2264. PubMed ID: 35844015
[TBL] [Abstract][Full Text] [Related]
5. A New Mini-External Fixator for Treating Hallux Valgus: A Preclinical, Biomechanical Study.
Erdil M; Ceylan HH; Polat G; Kara D; Bozdag E; Sunbuloglu E
J Foot Ankle Surg; 2016; 55(1):35-8. PubMed ID: 26190777
[TBL] [Abstract][Full Text] [Related]
6. Plate fixation for proximal chevron osteotomy has greater risk for hallux valgus recurrence than Kirschner wire fixation.
Park CH; Ahn JY; Kim YM; Lee WC
Int Orthop; 2013 Jun; 37(6):1085-92. PubMed ID: 23423428
[TBL] [Abstract][Full Text] [Related]
7. Mechanical comparison of two types of fixation for proximal first metatarsal crescentic osteotomy.
Jones C; Coughlin M; Petersen W; Herbot M; Paletta J
Foot Ankle Int; 2005 May; 26(5):371-4. PubMed ID: 15913520
[TBL] [Abstract][Full Text] [Related]
8. Mechanical comparison of cortical screw fixation versus locking plate fixation in first metatarsal base osteotomy.
Smith K; Lidtke RH; Oliver NG; Maker JM
J Foot Ankle Surg; 2014; 53(5):529-33. PubMed ID: 24954919
[TBL] [Abstract][Full Text] [Related]
9. Comparison of Clinical and Radiological Results of Two Fixation Materials after Distal Chevron Osteotomy for Hallux Valgus? - Two Kirschner Wires versus Single Screw Fixation.
Bİlgİn E; KeÇecİ T; Turgut A; Adiyeke L; Kİlİnc BE
Acta Chir Orthop Traumatol Cech; 2020; 87(5):350-355. PubMed ID: 33146604
[TBL] [Abstract][Full Text] [Related]
10. Biomechanical Comparison of a Novel Method of Tricortical Kirschner Wire Fixation of Distal Chevron Osteotomies of the First Metatarsal Versus Traditional Kirschner Wire and Versus Screw Fixation.
Chen J; Black NR; Morris R; Panchbhavi VK
Foot Ankle Spec; 2022 Oct; 15(5):426-431. PubMed ID: 33090018
[TBL] [Abstract][Full Text] [Related]
11. Biomechanical Comparison of Fixation With a Single Screw Versus Two Kirschner Wires in Distal Chevron Osteotomies of the First Metatarsal: A Cadaver Study.
Trost M; Bredow J; Boese CK; Loweg L; Schulte TL; Scaal M; Eysel P; Oppermann J
J Foot Ankle Surg; 2018; 57(1):95-99. PubMed ID: 29268910
[TBL] [Abstract][Full Text] [Related]
12. Strength of fixation constructs for basilar osteotomies of the first metatarsal.
Lian GJ; Markolf K; Cracchiolo A
Foot Ankle; 1992; 13(9):509-14. PubMed ID: 1478580
[TBL] [Abstract][Full Text] [Related]
13. Stability of a cannulated screw versus a Kirschner wire for the proximal crescentic osteotomy of the first metatarsal: a biomechanical study.
Bozkurt M; Tigaran C; Dalstra M; Jensen NC; Linde F
J Foot Ankle Surg; 2004; 43(3):138-43. PubMed ID: 15181429
[TBL] [Abstract][Full Text] [Related]
14. Screw Versus Plate Fixation for Chevron Osteotomy: A Retrospective Study.
Andrews BJ; Fallat LM; Kish JP
J Foot Ankle Surg; 2016; 55(1):81-4. PubMed ID: 26277241
[TBL] [Abstract][Full Text] [Related]
15. Fixation of metatarsal osteotomies in the treatment of hallux valgus.
Acevedo JI
Foot Ankle Clin; 2000 Sep; 5(3):451-68. PubMed ID: 11232391
[TBL] [Abstract][Full Text] [Related]
16. Mechanical comparison of two types of fixation for ludloff oblique first metatarsal osteotomy.
Tsilikas SP; Stamatis ED; Kourkoulis SK; Mitousoudis AS; Chatzistergos PE; Papagelopoulos PJ
J Foot Ankle Surg; 2011; 50(6):699-702. PubMed ID: 21813302
[TBL] [Abstract][Full Text] [Related]
17. Comparison of stability of proximal crescentic metatarsal osteotomy and proximal horizontal "V" osteotomy.
McCluskey LC; Johnson JE; Wynarsky GT; Harris GF
Foot Ankle Int; 1994 May; 15(5):263-70. PubMed ID: 7951965
[TBL] [Abstract][Full Text] [Related]
18. A Biomechanical Comparison of Fifth Metatarsal Jones Fracture Fixation Methods.
Duplantier NL; Mitchell RJ; Zambrano S; Stone AC; Delgado DA; Lambert BS; Moreno MR; Harris JD; McCulloch PC; Lintner DM; Varner KE
Am J Sports Med; 2018 Apr; 46(5):1220-1227. PubMed ID: 29466679
[TBL] [Abstract][Full Text] [Related]
19. Shortening Proximal Chevron Metatarsal Osteotomy for Patients With a Hallux Valgus Deformity With Advanced Arthritis.
Choi JY; Lee JM; Suh JS
J Foot Ankle Surg; 2019 Mar; 58(2):368-373. PubMed ID: 30612867
[TBL] [Abstract][Full Text] [Related]
20. Mechanical comparison of biplanar proximal closing wedge osteotomy with plantar plate fixation versus crescentic osteotomy with screw fixation for the correction of metatarsus primus varus.
Campbell JT; Schon LC; Parks BG; Wang Y; Berger BI
Foot Ankle Int; 1998 May; 19(5):293-9. PubMed ID: 9622419
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]