These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 2920884)

  • 41. Insulation failure in robotic and laparoscopic instrumentation: a prospective evaluation.
    Espada M; Munoz R; Noble BN; Magrina JF
    Am J Obstet Gynecol; 2011 Aug; 205(2):121.e1-5. PubMed ID: 21640966
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Simulated and experimental studies of temperature elevation around electrosurgical dispersive electrodes.
    Kim Y; Webster JG; Tompkins WJ
    IEEE Trans Biomed Eng; 1984 Nov; 31(11):681-92. PubMed ID: 6500588
    [No Abstract]   [Full Text] [Related]  

  • 43. Biomedical electrosurgery devices containing nanostructure for minimally invasive surgery: reduction of thermal injury and acceleration of wound healing for liver cancer.
    Hsiao WT; Lin LH; Chiang HJ; Ou KL; Cheng HY
    J Mater Sci Mater Med; 2015 Feb; 26(2):77. PubMed ID: 25631273
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Capacitive coupled stray currents during laparoscopic and endoscopic electrosurgical procedures.
    Tucker RD; Voyles CR; Silvis SE
    Biomed Instrum Technol; 1992; 26(4):303-11. PubMed ID: 1393200
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Direct-current potentials created by arcing during monopolar radiofrequency electrosurgery.
    Tucker RD; Kramolowsky EV; Stasz P
    Biomed Instrum Technol; 1990; 24(3):212-6. PubMed ID: 2344553
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Guideline Implementation: Energy-Generating Devices, Part 1-Electrosurgery.
    Eder SP
    AORN J; 2017 Mar; 105(3):300-310. PubMed ID: 28241952
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Human skin burns induced by defibrillator default current.
    Stoner DL; Yoo JH; Feldtman RW; Stanford W
    J Thorac Cardiovasc Surg; 1976 Jul; 72(1):157-61. PubMed ID: 933550
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Monday morning blues.
    Conway MW
    Occup Health Saf; 2001 Aug; 70(8):54, 56. PubMed ID: 11523286
    [No Abstract]   [Full Text] [Related]  

  • 49. [Protective measures against increase of the potential of a "grounded" passive electrode of the electrosurgical apparatus].
    Drabkin RL; Livenson AR
    Med Tekh; 1976; 0(3):20-4. PubMed ID: 1030771
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Electrical considerations of laparoscopic sterilization.
    Corson SL; Patrick H; Hamilton T; Bolognese RJ
    J Reprod Med; 1973 Oct; 11(4):159-64. PubMed ID: 4270295
    [No Abstract]   [Full Text] [Related]  

  • 51. In vivo measurements of leakage current during transurethral resection.
    Kay L
    Scand J Urol Nephrol; 1987; 21(3):209-11. PubMed ID: 3433021
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Correspondence: Electrosurgery burns.
    Hall SV; Malhotra IV; Hedley-White J
    Anesthesiology; 1975 May; 42(5):641-4. PubMed ID: 1130734
    [No Abstract]   [Full Text] [Related]  

  • 53. On electrosurgical indifferent plates.
    Albert SB
    N Y State Dent J; 1985 Nov; 51(9):510, 512. PubMed ID: 3865112
    [No Abstract]   [Full Text] [Related]  

  • 54. [The significance of the characteristics of lubricating jellies in use during transurethral prostate resections with metallic sheaths (author's transl)].
    Flachenecker G; Fastenmeier K; Schmiedt E; Eisenberger F
    Urologe A; 1977 May; 16(3):168-71. PubMed ID: 878111
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Electrosurgery burns resulting from use of miniature ECG electrodes.
    Finlay B; Couchie D; Boyce L; Spencer E
    Anesthesiology; 1974 Sep; 41(3):263-9. PubMed ID: 4851832
    [No Abstract]   [Full Text] [Related]  

  • 56. Numerical field calculation of patient return electrodes in electrosurgery.
    Raiser J; Golombeck MA; Dössel O
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 1():274-7. PubMed ID: 12451837
    [TBL] [Abstract][Full Text] [Related]  

  • 57. [Tracheal fire during tracheotomy: an unusual but extremely serious event].
    Lopez S; Marchand JH; Fossier T; Wu D; Inglès M
    Ann Fr Anesth Reanim; 2013 May; 32(5):375-6. PubMed ID: 23597569
    [No Abstract]   [Full Text] [Related]  

  • 58. [A new method of automatic regulation of the performance of high frequency surgical instruments].
    Kröber T
    Biomed Tech (Berl); 1990; 35 Suppl 3():200-2. PubMed ID: 2078696
    [No Abstract]   [Full Text] [Related]  

  • 59. Prevention of cautery burns during transurethral resection of prostate.
    Boyarsky S
    Urology; 1982 Dec; 20(6):599-601. PubMed ID: 7179625
    [No Abstract]   [Full Text] [Related]  

  • 60. Ground versus earth, there is a difference.
    Liebler GE
    J Forensic Sci; 1984 Apr; 29(2):550-6. PubMed ID: 6726159
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.