These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
114 related articles for article (PubMed ID: 29216084)
21. Reconstruction and calibration methods for a Mueller channeled spectropolarimeter. Zhou G; Li Y; Liu K Opt Express; 2022 Jan; 30(2):2018-2032. PubMed ID: 35209351 [TBL] [Abstract][Full Text] [Related]
23. Fourier transform channeled spectropolarimetry in the MWIR. Kudenov MW; Hagen NA; Dereniak EL; Gerhart GR Opt Express; 2007 Oct; 15(20):12792-805. PubMed ID: 19550549 [TBL] [Abstract][Full Text] [Related]
24. Compact static Fourier transform imaging spectropolarimeter based on channeled polarimetry. Li J; Zhu J; Wu H Opt Lett; 2010 Nov; 35(22):3784-6. PubMed ID: 21081996 [TBL] [Abstract][Full Text] [Related]
25. Spectroscopic polarimetry using channeled spectroscopic polarization state generator (CSPSG). Okabe H; Hayakawa M; Naito H; Taniguchi A; Oka K Opt Express; 2007 Mar; 15(6):3093-109. PubMed ID: 19532548 [TBL] [Abstract][Full Text] [Related]
26. Dynamic calibration for enhancing the stability of a channeled spectropolarimeter. Chrysler BD; Oka K; Otani Y; Hagen N Appl Opt; 2020 Oct; 59(30):9424-9433. PubMed ID: 33104659 [TBL] [Abstract][Full Text] [Related]
27. Channeled imaging spectropolarimeter reconstruction by neural networks. Lv X; Yang Z; Wang Y; Zhou K; Lin J; Jin P Opt Express; 2021 Oct; 29(22):35556-35569. PubMed ID: 34808986 [TBL] [Abstract][Full Text] [Related]
28. Linear calibration and reconstruction techniques for channeled spectropolarimetry. Sabatke D; Locke A; Dereniak E; McMillan R Opt Express; 2003 Nov; 11(22):2940-52. PubMed ID: 19471414 [TBL] [Abstract][Full Text] [Related]
29. Linear operator theory of channeled spectropolarimetry. Sabatke DS; Locke AM; Dereniak EL; McMillan RW J Opt Soc Am A Opt Image Sci Vis; 2005 Aug; 22(8):1567-76. PubMed ID: 16134852 [TBL] [Abstract][Full Text] [Related]
30. Detection and correction of wavefront errors caused by slight reference tilt in two-step phase-shifting digital holography. Xu X; Cai L; Gao F; Jia Y; Zhang H Appl Opt; 2015 Nov; 54(32):9591-6. PubMed ID: 26560791 [TBL] [Abstract][Full Text] [Related]
31. Polarimetric calibration of a spectropolarimeter instrument with high precision: Sunrise chromospheric infrared spectropolarimeter (SCIP) for the sunrise iii balloon telescope. Kawabata Y; Katsukawa Y; Kubo M; Anan T; Ichimoto K; Shinoda K; Tsuzuki T; Uraguchi F; Nagata S; Oba T; Expósito DH; Sánchez Gómez A; Orozco Suárez D; Balaguer Jiménz M; Bailón Martínez E; Morales Fernández JM; Moreno Mantas A; Del Toro Iniesta JC; Gandorfer A; Feller A Appl Opt; 2022 Nov; 61(32):9716-9736. PubMed ID: 36606914 [TBL] [Abstract][Full Text] [Related]
32. Auto calibration of a cone-beam-CT. Gross D; Heil U; Schulze R; Schoemer E; Schwanecke U Med Phys; 2012 Oct; 39(10):5959-70. PubMed ID: 23039634 [TBL] [Abstract][Full Text] [Related]
34. Optimizing the Calibration Error of Refraction Angles in Ultrasonic Angle Beam Testing. Cai Z; Jin Z; Zhu L; Li Y; Lei Y; Gao Z Sensors (Basel); 2020 Mar; 20(5):. PubMed ID: 32151104 [TBL] [Abstract][Full Text] [Related]
39. Online geometric calibration of cone-beam computed tomography for arbitrary imaging objects. Meng Y; Gong H; Yang X IEEE Trans Med Imaging; 2013 Feb; 32(2):278-88. PubMed ID: 23076032 [TBL] [Abstract][Full Text] [Related]