These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
116 related articles for article (PubMed ID: 2921688)
1. Low inspired gas temperature and respiratory complications in very low birth weight infants. Tarnow-Mordi WO; Reid E; Griffiths P; Wilkinson AR J Pediatr; 1989 Mar; 114(3):438-42. PubMed ID: 2921688 [TBL] [Abstract][Full Text] [Related]
2. Is neonatal inspired gas humidity accurately controlled by humidifier temperature? O'Hagan M; Reid E; Tarnow-Mordi WO Crit Care Med; 1991 Nov; 19(11):1370-3. PubMed ID: 1935156 [TBL] [Abstract][Full Text] [Related]
3. Inspired gas humidity during mechanical ventilation: effects of humidification chamber, airway temperature probe position and environmental conditions. Todd DA; Boyd J; Lloyd J; John E J Paediatr Child Health; 2001 Oct; 37(5):489-94. PubMed ID: 11885715 [TBL] [Abstract][Full Text] [Related]
4. Use of Normothermic Default Humidifier Settings Causes Excessive Humidification of Respiratory Gases During Therapeutic Hypothermia. Tanaka S; Iwata S; Kinoshita M; Tsuda K; Sakai S; Saikusa M; Shindo R; Harada E; Okada J; Hisano T; Kanda H; Maeno Y; Araki Y; Ushijima K; Sakamoto T; Yamashita Y; Iwata O Ther Hypothermia Temp Manag; 2016 Dec; 6(4):180-188. PubMed ID: 27167667 [TBL] [Abstract][Full Text] [Related]
5. Factors affecting humidity of inspired gas in a neonatal lung model. Rios A; Brion LP; Fleischman AR J Perinatol; 1998; 18(1):31-7. PubMed ID: 9527942 [TBL] [Abstract][Full Text] [Related]
6. Inspired gas humidity and temperature during mechanical ventilation with the Stephanie ventilator. Preo BL; Shadbolt B; Todd DA Paediatr Anaesth; 2013 Nov; 23(11):1062-8. PubMed ID: 23750698 [TBL] [Abstract][Full Text] [Related]
7. Inspired gas temperature in ventilated neonates. Davies MW; Dunster KR; Cartwright DW Pediatr Pulmonol; 2004 Jul; 38(1):50-4. PubMed ID: 15170873 [TBL] [Abstract][Full Text] [Related]
8. [New potentials for monitoring the temperature and the relative and absolute humidity of the air-oxygen mixture during the prolonged artificial ventilation of newborn infants]. Milenin OB; Efimov MS Anesteziol Reanimatol; 1998; (1):49-52. PubMed ID: 9553263 [TBL] [Abstract][Full Text] [Related]
9. The Effect of 2 Humidifier Temperature Settings on Inspired Gas Temperatures and the Physiological Parameters of Preterm Infants Receiving Mechanical Ventilation Therapy. Bayraktar S; Balcı S; Ince Z Adv Neonatal Care; 2021 Aug; 21(4):308-313. PubMed ID: 33350709 [TBL] [Abstract][Full Text] [Related]
10. The effect of inlet gas temperatures on heated humidifier performance. Carter BG; Whittington N; Hochmann M; Osborne A J Aerosol Med; 2002; 15(1):7-13. PubMed ID: 12006141 [TBL] [Abstract][Full Text] [Related]
11. The temperature and humidity of inspired gases in infants using a pediatric circle system: effects of high and low-flow anesthesia. Hunter T; Lerman J; Bissonnette B Paediatr Anaesth; 2005 Sep; 15(9):750-4. PubMed ID: 16101705 [TBL] [Abstract][Full Text] [Related]
12. [Humidification and heating of anesthetic gases during pediatric anesthesia using the Cicero Anesthesia Workstation]. Strauss JM; Hausdörfer J; Hagemann H; Schröder D Anaesthesist; 1992 Sep; 41(9):534-8. PubMed ID: 1416008 [TBL] [Abstract][Full Text] [Related]
13. Risk factors for pneumothorax in very low birth weight infants. Klinger G; Ish-Hurwitz S; Osovsky M; Sirota L; Linder N Pediatr Crit Care Med; 2008 Jul; 9(4):398-402. PubMed ID: 18496417 [TBL] [Abstract][Full Text] [Related]
14. Initial respiratory support with cold, dry gas versus heated humidified gas and admission temperature of preterm infants. Meyer MP; Hou D; Ishrar NN; Dito I; te Pas AB J Pediatr; 2015 Feb; 166(2):245-50.e1. PubMed ID: 25449225 [TBL] [Abstract][Full Text] [Related]
15. Evidence of inadequate humidification of inspired gas during artificial ventilation of newborn babies in the British Isles. Tarnow-Mordi WO; Fletcher M; Sutton P; Wilkinson AR Lancet; 1986 Oct; 2(8512):909-10. PubMed ID: 2876338 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of the Humidification Performances of New Generation of Heated Wire Humidifiers. Lellouche F; Rousseau E; Bouchard PA Respir Care; 2024 Mar; 69(4):430-437. PubMed ID: 37734763 [TBL] [Abstract][Full Text] [Related]
17. Do clinical markers of barotrauma and oxygen toxicity explain interhospital variation in rates of chronic lung disease? The Neonatology Committee for the Developmental Network. Van Marter LJ; Allred EN; Pagano M; Sanocka U; Parad R; Moore M; Susser M; Paneth N; Leviton A Pediatrics; 2000 Jun; 105(6):1194-201. PubMed ID: 10835057 [TBL] [Abstract][Full Text] [Related]
18. A clinical comparison of radiant warmer and incubator care for preterm infants from birth to 1800 grams. Meyer MP; Payton MJ; Salmon A; Hutchinson C; de Klerk A Pediatrics; 2001 Aug; 108(2):395-401. PubMed ID: 11483805 [TBL] [Abstract][Full Text] [Related]
19. Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min. Martin C; Thomachot L; Quinio B; Viviand X; Albanese J Chest; 1995 May; 107(5):1411-5. PubMed ID: 7750340 [TBL] [Abstract][Full Text] [Related]
20. Inspired gas temperature during mechanical ventilation: effects of environmental temperature and airway temperature probe position. Todd DA; Boyd J; Lloyd J; John E J Paediatr Child Health; 2001 Oct; 37(5):495-500. PubMed ID: 11885716 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]