These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

636 related articles for article (PubMed ID: 29216976)

  • 21. First in-human evaluation of a novel intravascular ultrasound and optical coherence tomography system for intracoronary imaging.
    Akl E; Pinilla-Echeverri N; Garcia-Garcia HM; Mehta SR; Dan K; Kuku KO; Courtney BK; Sheth T
    Catheter Cardiovasc Interv; 2022 Feb; 99(3):686-698. PubMed ID: 34792273
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Optical coherence tomography versus intravascular ultrasound to evaluate coronary artery disease and percutaneous coronary intervention.
    Bezerra HG; Attizzani GF; Sirbu V; Musumeci G; Lortkipanidze N; Fujino Y; Wang W; Nakamura S; Erglis A; Guagliumi G; Costa MA
    JACC Cardiovasc Interv; 2013 Mar; 6(3):228-36. PubMed ID: 23517833
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Combined use of optical coherence tomography and intravascular ultrasound imaging in patients undergoing coronary interventions for stent thrombosis.
    Alfonso F; Dutary J; Paulo M; Gonzalo N; Pérez-Vizcayno MJ; Jiménez-Quevedo P; Escaned J; Bañuelos C; Hernández R; Macaya C
    Heart; 2012 Aug; 98(16):1213-20. PubMed ID: 22826559
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Optical coherence tomography versus angiography and intravascular ultrasound to guide coronary stent implantation: A systematic review and meta-analysis.
    Siddiqi TJ; Khan MS; Karimi Galougahi K; Shlofmitz E; Moses JW; Rao S; West NEJ; Wolff E; Hochler J; Chau K; Khalique O; Shlofmitz RA; Jeremias A; Ali ZA
    Catheter Cardiovasc Interv; 2022 Nov; 100 Suppl 1():S44-S56. PubMed ID: 36251325
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Classification of mechanisms of strut malapposition after angiographically optimized stent implantation: An optical coherence tomography study.
    Agrawal M; Hakeem A; Ahmed Z; Uretsky BF
    Catheter Cardiovasc Interv; 2017 Aug; 90(2):225-232. PubMed ID: 28805036
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Angiographically confirmed stent thrombosis in contemporary practice: insights from intravascular ultrasound.
    Armstrong EJ; Kwa AT; Yeo KK; Mahmud E; Javed U; Patel M; Shunk KA; MacGregor JS; Low RI; Rogers JH
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):782-90. PubMed ID: 22511567
    [TBL] [Abstract][Full Text] [Related]  

  • 27. First-in-Human Evaluation of a Novel Polymer-Free Drug-Filled Stent: Angiographic, IVUS, OCT, and Clinical Outcomes From the RevElution Study.
    Worthley SG; Abizaid A; Kirtane AJ; Simon DI; Windecker S; Brar S; Meredith IT; Shetty S; Sinhal A; Almonacid AP; Chamié D; Maehara A; Stone GW;
    JACC Cardiovasc Interv; 2017 Jan; 10(2):147-156. PubMed ID: 28104208
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Outcomes of optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation: one-year results from the ILUMIEN III: OPTIMIZE PCI trial.
    Ali ZA; Karimi Galougahi K; Maehara A; Shlofmitz RA; Fabbiocchi F; Guagliumi G; Alfonso F; Akasaka T; Matsumura M; Mintz GS; Ben-Yehuda O; Zhang Z; Rapoza RR; West NEJ; Stone GW
    EuroIntervention; 2021 Jan; 16(13):1085-1091. PubMed ID: 32540793
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients.
    Shin DH; Hong SJ; Mintz GS; Kim JS; Kim BK; Ko YG; Choi D; Jang Y; Hong MK
    JACC Cardiovasc Interv; 2016 Nov; 9(21):2232-2239. PubMed ID: 27744039
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Angiography Alone Versus Angiography Plus Optical Coherence Tomography to Guide Percutaneous Coronary Intervention: Outcomes From the Pan-London PCI Cohort.
    Jones DA; Rathod KS; Koganti S; Hamshere S; Astroulakis Z; Lim P; Sirker A; O'Mahony C; Jain AK; Knight CJ; Dalby MC; Malik IS; Mathur A; Rakhit R; Lockie T; Redwood S; MacCarthy PA; Desilva R; Weerackody R; Wragg A; Smith EJ; Bourantas CV
    JACC Cardiovasc Interv; 2018 Jul; 11(14):1313-1321. PubMed ID: 30025725
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison between Optical COherence tomography guidance and Angiography guidance in percutaneous coronary intervention (COCOA): Study protocol for a randomized controlled trial.
    Kubo T; Shinke T; Okamura T; Hibi K; Nakazawa G; Morino Y; Shite J; Ino Y; Kitabata H; Shimokawa T; Akasaka T
    J Cardiol; 2018 Aug; 72(2):170-175. PubMed ID: 29486964
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Intravascular Ultrasound Imaging-Guided Versus Coronary Angiography-Guided Percutaneous Coronary Intervention: A Systematic Review and Meta-Analysis.
    Darmoch F; Alraies MC; Al-Khadra Y; Moussa Pacha H; Pinto DS; Osborn EA
    J Am Heart Assoc; 2020 Mar; 9(5):e013678. PubMed ID: 32075491
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of optical coherence tomography-guided versus intravascular ultrasound-guided percutaneous coronary intervention: Rationale and design of a randomized, controlled OCTIVUS trial.
    Kang DY; Ahn JM; Park H; Lee PH; Kang SJ; Lee SW; Kim YH; Park SW; Kim SW; Hur SH; Cho YK; Lee CH; Hong SJ; Hong YJ; Yoon YW; Kim SJ; Bae JH; Oh JH; Park DW; Park SJ
    Am Heart J; 2020 Oct; 228():72-80. PubMed ID: 32871327
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Multi-modality imaging for stent edge assessment.
    Ann SH; Lim KH; De Jin C; Shin ES
    Heart Vessels; 2015 Mar; 30(2):162-8. PubMed ID: 24481539
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Value of intravascular ultrasound in guiding coronary interventions.
    Song HG; Kang SJ; Mintz GS
    Echocardiography; 2018 Apr; 35(4):520-533. PubMed ID: 29679449
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Optical Coherence Tomography Comparison of Percutaneous Coronary Intervention Among Plaque Rupture, Erosion, and Calcified Nodule in Acute Myocardial Infarction.
    Khalifa AKM; Kubo T; Ino Y; Terada K; Emori H; Higashioka D; Katayama Y; Takahata M; Shimamura K; Shiono Y; Matsuo Y; Tanaka A; Hozumi T; Akasaka T
    Circ J; 2020 May; 84(6):911-916. PubMed ID: 32307358
    [TBL] [Abstract][Full Text] [Related]  

  • 37. OCT analysis in patients with very late stent thrombosis.
    Kang SJ; Lee CW; Song H; Ahn JM; Kim WJ; Lee JY; Park DW; Lee SW; Kim YH; Mintz GS; Park SW; Park SJ
    JACC Cardiovasc Imaging; 2013 Jun; 6(6):695-703. PubMed ID: 23643282
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Serial intravascular ultrasound analysis of complex bifurcation coronary lesions treated with the Tryton Bifurcation Stent in conjunction with an everolimus-eluting stent: IUVANT (Intravascular Ultrasound Evaluation of Tryton Stent) study.
    Bartorelli AL; Trabattoni D; Almonacid A; Fabbiocchi F; Montorsi P; Galli S; Grancini L; Ravagnani P; Mintz GS; Kaplan AV; Popma JJ; Maehara A
    Catheter Cardiovasc Interv; 2015 Mar; 85(4):544-53. PubMed ID: 25115944
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Impact of Intracoronary Optical Coherence Tomography in Routine Clinical Practice: A Contemporary Cohort Study.
    Häner JD; Duband B; Ueki Y; Otsuka T; Combaret N; Siontis GCM; Bär S; Stortecky S; Motreff P; Losdat S; Windecker S; Souteyrand G; Räber L
    Cardiovasc Revasc Med; 2022 May; 38():96-103. PubMed ID: 34340915
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of Early Healing Profile and Neointimal Transformation Over 24 Months Using Longitudinal Sequential Optical Coherence Tomography Assessments and 3-Year Clinical Results of the New Dual-Therapy Endothelial Progenitor Cell Capturing Sirolimus-Eluting Combo Stent: The EGO-Combo Study.
    Lee SW; Lam SC; Tam FC; Chan KK; Shea CP; Kong SL; Wong AY; Yung A; Zhang LW; Tse HF; Wu KK; Chan R; Haude M; Mehran R; Mintz GS; Maehara A
    Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27418609
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 32.