144 related articles for article (PubMed ID: 29217331)
21. Dosimetric effects of positioning shifts using 6D-frameless stereotactic Brainlab system in hypofractionated intracranial radiotherapy.
Jin H; Keeling VP; Ali I; Ahmad S
J Appl Clin Med Phys; 2016 Jan; 17(1):102-111. PubMed ID: 26894336
[TBL] [Abstract][Full Text] [Related]
22. Evaluation of initial setup accuracy and intrafraction motion for spine stereotactic body radiation therapy using stereotactic body frames.
Han Z; Bondeson JC; Lewis JH; Mannarino EG; Friesen SA; Wagar MM; Balboni TA; Alexander BM; Arvold ND; Sher DJ; Hacker FL
Pract Radiat Oncol; 2016; 6(1):e17-24. PubMed ID: 26603596
[TBL] [Abstract][Full Text] [Related]
23. Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy.
Mallory M; Pokhrel D; Badkul R; Jiang H; Lominska C; Wang F
J Appl Clin Med Phys; 2018 Mar; 19(2):54-61. PubMed ID: 29349867
[TBL] [Abstract][Full Text] [Related]
24. Feasibility study of real-time planning for stereotactic radiosurgery.
Zhang Q; Song Y; Chan M; Burman C; Yamada Y
Med Phys; 2013 Mar; 40(3):031711. PubMed ID: 23464306
[TBL] [Abstract][Full Text] [Related]
25. Impact of pitch angle setup error and setup error correction on dose distribution in volumetric modulated arc therapy for prostate cancer.
Takemura A; Togawa K; Yokoi T; Ueda S; Noto K; Kojima H; Isomura N; Kumano T
Radiol Phys Technol; 2016 Jul; 9(2):178-86. PubMed ID: 26873139
[TBL] [Abstract][Full Text] [Related]
26. Spine stereotactic body radiotherapy utilizing cone-beam CT image-guidance with a robotic couch: intrafraction motion analysis accounting for all six degrees of freedom.
Hyde D; Lochray F; Korol R; Davidson M; Wong CS; Ma L; Sahgal A
Int J Radiat Oncol Biol Phys; 2012 Mar; 82(3):e555-62. PubMed ID: 22284042
[TBL] [Abstract][Full Text] [Related]
27. Analysis of dosimetric impact of intrafraction translation and rotation during respiratory-gated stereotactic body radiotherapy with real-time tumor monitoring of the lung using a novel six degrees-of-freedom robotic moving phantom.
Shiinoki T; Fujii F; Yuasa Y; Nonomura T; Fujimoto K; Sera T; Tanaka H
Med Phys; 2020 Sep; 47(9):3870-3881. PubMed ID: 32623741
[TBL] [Abstract][Full Text] [Related]
28. Clinical evaluation of a robotic 6-degree of freedom treatment couch for frameless radiosurgery.
Gevaert T; Verellen D; Engels B; Depuydt T; Heuninckx K; Tournel K; Duchateau M; Reynders T; De Ridder M
Int J Radiat Oncol Biol Phys; 2012 May; 83(1):467-74. PubMed ID: 21945110
[TBL] [Abstract][Full Text] [Related]
29. On the use of volumetric-modulated arc therapy for single-fraction thoracic vertebral metastases stereotactic body radiosurgery.
Pokhrel D; Sood S; McClinton C; Shen X; Badkul R; Jiang H; Mallory M; Mitchell M; Wang F; Lominska C
Med Dosim; 2017 Spring; 42(1):69-75. PubMed ID: 28129972
[TBL] [Abstract][Full Text] [Related]
30. An approach for online evaluations of dose consequences caused by small rotational setup errors in intracranial stereotactic radiation therapy.
Lu B; Li J; Kahler D; Yan G; Mittauer K; Shi W; Okunieff P; Liu C
Med Phys; 2011 Nov; 38(11):6203-15. PubMed ID: 22047385
[TBL] [Abstract][Full Text] [Related]
31. Dosimetric consequences of rotational setup errors with direct simulation in a treatment planning system for fractionated stereotactic radiotherapy.
Peng JL; Liu C; Chen Y; Amdur RJ; Vanek K; Li JG
J Appl Clin Med Phys; 2011 Apr; 12(3):3422. PubMed ID: 21844852
[TBL] [Abstract][Full Text] [Related]
32. Monitoring frequency of intra-fraction patient motion using the ExacTrac system for LINAC-based SRS treatments.
Lewis BC; Snyder WJ; Kim S; Kim T
J Appl Clin Med Phys; 2018 May; 19(3):58-63. PubMed ID: 29577592
[TBL] [Abstract][Full Text] [Related]
33. Residual rotational error of X-ray volume imaging system and its dosimetric effect in spinal tumor radiation therapy.
Peng J; Chang X; Xu Z; Wang J; Guan X; Cheng L; Zhang Z; Hu W
Australas Phys Eng Sci Med; 2013 Jun; 36(2):193-9. PubMed ID: 23636716
[TBL] [Abstract][Full Text] [Related]
34. Translational and rotational localization errors in cone-beam CT based image-guided lung stereotactic radiotherapy.
Garibaldi C; Piperno G; Ferrari A; Surgo A; Muto M; Ronchi S; Bazani A; Pansini F; Cremonesi M; Jereczek-Fossa BA; Orecchia R
Phys Med; 2016 Jul; 32(7):859-65. PubMed ID: 27289354
[TBL] [Abstract][Full Text] [Related]
35. Calculation of rotational setup error using the real-time tracking radiation therapy (RTRT) system and its application to the treatment of spinal schwannoma.
Onimaru R; Shirato H; Aoyama H; Kitakura K; Seki T; Hida K; Fujita K; Kagei K; Nishioka T; Kunieda T; Iwasaki Y; Miyasaka K
Int J Radiat Oncol Biol Phys; 2002 Nov; 54(3):939-47. PubMed ID: 12377348
[TBL] [Abstract][Full Text] [Related]
36. Local setup reproducibility of the spinal column when using intensity-modulated radiation therapy for craniospinal irradiation with patient in supine position.
Stoiber EM; Giske K; Schubert K; Sterzing F; Habl G; Uhl M; Herfarth K; Bendl R; Debus J
Int J Radiat Oncol Biol Phys; 2011 Dec; 81(5):1552-9. PubMed ID: 20888708
[TBL] [Abstract][Full Text] [Related]
37. Assessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy.
Pokhrel D; Sood S; Badkul R; Jiang H; McClinton C; Lominska C; Kumar P; Wang F
J Appl Clin Med Phys; 2016 May; 17(3):277-293. PubMed ID: 27167284
[TBL] [Abstract][Full Text] [Related]
38. Re-irradiation of spinal column metastases by IMRT: impact of setup errors on the dose distribution.
Gröger C; Hautmann MG; Loeschel R; Repp N; Kölbl O; Dobler B
Radiat Oncol; 2013 Nov; 8():269. PubMed ID: 24238332
[TBL] [Abstract][Full Text] [Related]
39. Positional Accuracy of Treating Multiple Versus Single Vertebral Metastases With Stereotactic Body Radiotherapy.
Chang JH; Sangha A; Hyde D; Soliman H; Myrehaug S; Ruschin M; Lee Y; Sahgal A; Korol R
Technol Cancer Res Treat; 2017 Apr; 16(2):231-237. PubMed ID: 28279146
[TBL] [Abstract][Full Text] [Related]
40. Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer.
Yang Y; Catalano S; Kelsey CR; Yoo DS; Yin FF; Cai J
Med Dosim; 2014; 39(1):117-21. PubMed ID: 24485056
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]