These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 29238821)

  • 1. Multibody Kinematics Optimization for the Estimation of Upper and Lower Limb Human Joint Kinematics: A Systematized Methodological Review.
    Begon M; Andersen MS; Dumas R
    J Biomech Eng; 2018 Mar; 140(3):. PubMed ID: 29238821
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Kinematic models of the upper limb joints for multibody kinematics optimisation: An overview.
    Duprey S; Naaim A; Moissenet F; Begon M; Chèze L
    J Biomech; 2017 Sep; 62():87-94. PubMed ID: 27986326
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multibody kinematics optimization with marker projection improves the accuracy of the humerus rotational kinematics.
    Begon M; Bélaise C; Naaim A; Lundberg A; Chèze L
    J Biomech; 2017 Sep; 62():117-123. PubMed ID: 27793407
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Model-based approach for human kinematics reconstruction from markerless and marker-based motion analysis systems.
    Sholukha V; Bonnechere B; Salvia P; Moiseev F; Rooze M; Van Sint Jan S
    J Biomech; 2013 Sep; 46(14):2363-71. PubMed ID: 23972432
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Joint kinematics estimation using a multi-body kinematics optimisation and an extended Kalman filter, and embedding a soft tissue artefact model.
    Bonnet V; Richard V; Camomilla V; Venture G; Cappozzo A; Dumas R
    J Biomech; 2017 Sep; 62():148-155. PubMed ID: 28551098
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of various upper limb multibody models on soft tissue artefact correction: A case study.
    Naaim A; Moissenet F; Duprey S; Begon M; Chèze L
    J Biomech; 2017 Sep; 62():102-109. PubMed ID: 28274475
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of a multibody kinematics optimization method for three-dimensional canine pelvic limb gait analysis.
    Lin CC; Wu CH; Chou PY; Wang SN; Hsu WR; Lu TW
    BMC Vet Res; 2020 Apr; 16(1):105. PubMed ID: 32245381
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Kinetics influence of multibody kinematics optimisation for soft tissue artefact compensation.
    Pomarat Z; Guitteny S; Dumas R; Muller A
    J Biomech; 2023 Mar; 150():111514. PubMed ID: 36867951
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Kinematic models of lower limb joints for musculo-skeletal modelling and optimization in gait analysis.
    Leardini A; Belvedere C; Nardini F; Sancisi N; Conconi M; Parenti-Castelli V
    J Biomech; 2017 Sep; 62():77-86. PubMed ID: 28601242
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Does IMU redundancy improve multi-body optimization results to obtain lower-body kinematics? A preliminary study says no.
    Couvertier M; Pacher L; Fradet L
    J Biomech; 2024 May; 168():112091. PubMed ID: 38640829
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Global sensitivity analysis of the joint kinematics during gait to the parameters of a lower limb multi-body model.
    El Habachi A; Moissenet F; Duprey S; Cheze L; Dumas R
    Med Biol Eng Comput; 2015 Jul; 53(7):655-67. PubMed ID: 25783762
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparative assessment of knee joint models used in multi-body kinematics optimisation for soft tissue artefact compensation.
    Richard V; Cappozzo A; Dumas R
    J Biomech; 2017 Sep; 62():95-101. PubMed ID: 28237187
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the global optimisation method within the upper limb kinematics analysis.
    Roux E; Bouilland S; Godillon-Maquinghen AP; Bouttens D
    J Biomech; 2002 Sep; 35(9):1279-83. PubMed ID: 12163317
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In situ comparison of A-mode ultrasound tracking system and skin-mounted markers for measuring kinematics of the lower extremity.
    Niu K; Anijs T; Sluiter V; Homminga J; Sprengers A; Marra MA; Verdonschot N
    J Biomech; 2018 Apr; 72():134-143. PubMed ID: 29573792
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of a Scaled Cadaver-Based Musculoskeletal Model With a Clinical Upper Extremity Model.
    Nagaraja VH; Bergmann JHM; Andersen MS; Thompson MS
    J Biomech Eng; 2023 Apr; 145(4):. PubMed ID: 36346198
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of joint constraints on lower limb kinematics estimation from skin markers using global optimization.
    Duprey S; Cheze L; Dumas R
    J Biomech; 2010 Oct; 43(14):2858-62. PubMed ID: 20701914
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Standardization proposal of soft tissue artefact description for data sharing in human motion measurements.
    Cereatti A; Bonci T; Akbarshahi M; Aminian K; Barré A; Begon M; Benoit DL; Charbonnier C; Dal Maso F; Fantozzi S; Lin CC; Lu TW; Pandy MG; Stagni R; van den Bogert AJ; Camomilla V
    J Biomech; 2017 Sep; 62():5-13. PubMed ID: 28259462
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development and evaluation of a new methodology for Soft Tissue Artifact compensation in the lower limb.
    Lahkar BK; Rohan PY; Assi A; Pillet H; Bonnet X; Thoreux P; Skalli W
    J Biomech; 2021 Jun; 122():110464. PubMed ID: 33932915
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Musculoskeletal multibody dynamics simulation of the contact mechanics and kinematics of a natural knee joint during a walking cycle.
    Hu J; Chen Z; Xin H; Zhang Q; Jin Z
    Proc Inst Mech Eng H; 2018 May; 232(5):508-519. PubMed ID: 29637803
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Kalman smoothing improves the estimation of joint kinematics and kinetics in marker-based human gait analysis.
    De Groote F; De Laet T; Jonkers I; De Schutter J
    J Biomech; 2008 Dec; 41(16):3390-8. PubMed ID: 19026414
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.