These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 29247876)

  • 41. An ultrasound elastography method to determine the local stiffness of arteries with guided circumferential waves.
    Li GY; He Q; Xu G; Jia L; Luo J; Cao Y
    J Biomech; 2017 Jan; 51():97-104. PubMed ID: 27989313
    [TBL] [Abstract][Full Text] [Related]  

  • 42. A Hertzian contact mechanics based formulation to improve ultrasound elastography assessment of uterine cervical tissue stiffness.
    Briggs BN; Stender ME; Muljadi PM; Donnelly MA; Winn VD; Ferguson VL
    J Biomech; 2015 Jun; 48(9):1524-32. PubMed ID: 26003483
    [TBL] [Abstract][Full Text] [Related]  

  • 43. MR elastography of the liver and the spleen using a piezoelectric driver, single-shot wave-field acquisition, and multifrequency dual parameter reconstruction.
    Hirsch S; Guo J; Reiter R; Papazoglou S; Kroencke T; Braun J; Sack I
    Magn Reson Med; 2014 Jan; 71(1):267-77. PubMed ID: 23413115
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Time-of-flight and noise-correlation-inspired algorithms for full-field shear-wave elastography using digital holography.
    Marmin A; Laloy-Borgna G; Facca S; Gioux S; Catheline S; Nahas A
    J Biomed Opt; 2021 Aug; 26(8):. PubMed ID: 34414704
    [TBL] [Abstract][Full Text] [Related]  

  • 45. In vivo elasticity measurements of extremity skeletal muscle with MR elastography.
    Uffmann K; Maderwald S; Ajaj W; Galban CG; Mateiescu S; Quick HH; Ladd ME
    NMR Biomed; 2004 Jun; 17(4):181-90. PubMed ID: 15229931
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Carotid plaque elasticity estimation using ultrasound elastography, MRI, and inverse FEA - A numerical feasibility study.
    Nieuwstadt HA; Fekkes S; Hansen HH; de Korte CL; van der Lugt A; Wentzel JJ; van der Steen AF; Gijsen FJ
    Med Eng Phys; 2015 Aug; 37(8):801-7. PubMed ID: 26130603
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Influence of wall thickness and diameter on arterial shear wave elastography: a phantom and finite element study.
    Maksuti E; Bini F; Fiorentini S; Blasi G; Urban MW; Marinozzi F; Larsson M
    Phys Med Biol; 2017 Apr; 62(7):2694-2718. PubMed ID: 28081009
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Visualization and quantification of breast cancer biomechanical properties with magnetic resonance elastography.
    Plewes DB; Bishop J; Samani A; Sciarretta J
    Phys Med Biol; 2000 Jun; 45(6):1591-610. PubMed ID: 10870713
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Quantification of breast stiffness using MR elastography at 3 Tesla with a soft sternal driver: A reproducibility study.
    Hawley JR; Kalra P; Mo X; Raterman B; Yee LD; Kolipaka A
    J Magn Reson Imaging; 2017 May; 45(5):1379-1384. PubMed ID: 27779802
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Rescaled Local Interaction Simulation Approach for Shear Wave Propagation Modelling in Magnetic Resonance Elastography.
    Hashemiyan Z; Packo P; Staszewski WJ; Uhl T
    Comput Math Methods Med; 2016; 2016():9343017. PubMed ID: 26884808
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Magnetic resonance elastography: non-invasive mapping of tissue elasticity.
    Manduca A; Oliphant TE; Dresner MA; Mahowald JL; Kruse SA; Amromin E; Felmlee JP; Greenleaf JF; Ehman RL
    Med Image Anal; 2001 Dec; 5(4):237-54. PubMed ID: 11731304
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Imaging the shear modulus of the heel fat pads.
    Weaver JB; Doyley M; Cheung Y; Kennedy F; Madsen EL; Van Houten EE; Paulsen K
    Clin Biomech (Bristol, Avon); 2005 Mar; 20(3):312-9. PubMed ID: 15698705
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Multi-source and multi-directional shear wave generation with intersecting steered ultrasound push beams.
    Nabavizadeh A; Song P; Chen S; Greenleaf JF; Urban MW
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Apr; 62(4):647-62. PubMed ID: 25881343
    [TBL] [Abstract][Full Text] [Related]  

  • 54. A multiresolution approach to shear wave image reconstruction.
    Hollender P; Bottenus N; Trahey G
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Aug; 62(8):1429-39. PubMed ID: 26276953
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Elasticity reconstruction from displacement and confidence measures of a multi-compressed ultrasound RF sequence.
    Li J; Cui Y; Kadour M; Noble JA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Feb; 55(2):319-26. PubMed ID: 18334339
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Quantification of aortic stiffness using magnetic resonance elastography: Measurement reproducibility, pulse wave velocity comparison, changes over cardiac cycle, and relationship with age.
    Kenyhercz WE; Raterman B; Illapani VS; Dowell J; Mo X; White RD; Kolipaka A
    Magn Reson Med; 2016 May; 75(5):1920-6. PubMed ID: 26096227
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Measurement of in vivo local shear modulus using MR elastography multiple-phase patchwork offsets.
    Suga M; Matsuda T; Minato K; Oshiro O; Chihara K; Okamoto J; Takizawa O; Komori M; Takahashi T
    IEEE Trans Biomed Eng; 2003 Jul; 50(7):908-15. PubMed ID: 12848359
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A finite element model for analyzing shear wave propagation observed in magnetic resonance elastography.
    Chen Q; Ringleb SI; Manduca A; Ehman RL; An KN
    J Biomech; 2005 Nov; 38(11):2198-203. PubMed ID: 16154406
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Quantitative shear wave magnetic resonance elastography: comparison to a dynamic shear material test.
    Ringleb SI; Chen Q; Lake DS; Manduca A; Ehman RL; An KN
    Magn Reson Med; 2005 May; 53(5):1197-201. PubMed ID: 15844144
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Computer-aided diagnosis based on quantitative elastographic features with supersonic shear wave imaging.
    Xiao Y; Zeng J; Niu L; Zeng Q; Wu T; Wang C; Zheng R; Zheng H
    Ultrasound Med Biol; 2014 Feb; 40(2):275-86. PubMed ID: 24268454
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.