174 related articles for article (PubMed ID: 29251387)
1. Utilization of multiple SAVI SCOUT surgical guidance system reflectors in the same breast: A single-institution feasibility study.
Jadeja PH; Mango V; Patel S; Friedlander L; Desperito E; Ayala-Bustamante E; Wynn R; Chen-Seetoo M; Taback B; Feldman S; Ha R
Breast J; 2018 Jul; 24(4):531-534. PubMed ID: 29251387
[TBL] [Abstract][Full Text] [Related]
2. Beyond Wires and Seeds: Reflector-guided Breast Lesion Localization and Excision.
Mango VL; Wynn RT; Feldman S; Friedlander L; Desperito E; Patel SN; Gomberawalla A; Ha R
Radiology; 2017 Aug; 284(2):365-371. PubMed ID: 28430555
[TBL] [Abstract][Full Text] [Related]
3. SAVI SCOUT® localization of breast lesions as a practical alternative to wires: Outcomes and suggestions for trouble-shooting.
Falcon S; Weinfurtner RJ; Mooney B; Niell BL
Clin Imaging; 2018; 52():280-286. PubMed ID: 30193186
[TBL] [Abstract][Full Text] [Related]
4. Savi Scout Radar Localization Versus Wire Localization for Breast Biopsy Regarding Positive Margin, Complication, and Reoperation Rates.
Tingen JS; McKinley BP; Rinkliff JM; Cornett WR; Lucas C
Am Surg; 2020 Aug; 86(8):1029-1031. PubMed ID: 32721172
[TBL] [Abstract][Full Text] [Related]
5. A Prospective, Single Arm, Multi-site, Clinical Evaluation of a Nonradioactive Surgical Guidance Technology for the Location of Nonpalpable Breast Lesions during Excision.
Cox CE; Russell S; Prowler V; Carter E; Beard A; Mehindru A; Blumencranz P; Allen K; Portillo M; Whitworth P; Funk K; Barone J; Norton D; Schroeder J; Police A; Lin E; Combs F; Schnabel F; Toth H; Lee J; Anglin B; Nguyen M; Canavan L; Laidley A; Warden MJ; Prati R; King J; Shivers SC
Ann Surg Oncol; 2016 Oct; 23(10):3168-74. PubMed ID: 27469121
[TBL] [Abstract][Full Text] [Related]
6. Pilot Study of a New Nonradioactive Surgical Guidance Technology for Locating Nonpalpable Breast Lesions.
Cox CE; Garcia-Henriquez N; Glancy MJ; Whitworth P; Cox JM; Themar-Geck M; Prati R; Jung M; Russell S; Appleton K; King J; Shivers SC
Ann Surg Oncol; 2016 Jun; 23(6):1824-30. PubMed ID: 26847680
[TBL] [Abstract][Full Text] [Related]
7. SAVI Scout® System for Excision of Non-Palpable Breast Lesions.
Farha MJ; Simons J; Kfouri J; Townsend-Day M
Am Surg; 2023 Jun; 89(6):2434-2438. PubMed ID: 35509218
[TBL] [Abstract][Full Text] [Related]
8. Review of Variables Associated With Positive Surgical Margins Using Scout Reflector Localizations for Breast Conservation Therapy.
Choe AI; Ismail R; Mack J; Walter V; Yang AL; Dodge DG
Clin Breast Cancer; 2022 Feb; 22(2):e232-e238. PubMed ID: 34348869
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of the SAVI SCOUT Surgical Guidance System for Localization and Excision of Nonpalpable Breast Lesions: A Feasibility Study.
Mango V; Ha R; Gomberawalla A; Wynn R; Feldman S
AJR Am J Roentgenol; 2016 Oct; 207(4):W69-W72. PubMed ID: 27304083
[TBL] [Abstract][Full Text] [Related]
10. A comparison of two non-radioactive alternatives to wire for the localization of non-palpable breast cancers.
Lee MK; Sanaiha Y; Kusske AM; Thompson CK; Attai DJ; Baker JL; Fischer CP; DiNome ML
Breast Cancer Res Treat; 2020 Jul; 182(2):299-303. PubMed ID: 32451679
[TBL] [Abstract][Full Text] [Related]
11. Savi Scout® Radar Localisation of Non-palpable Breast Lesions: Systematic Review and Pooled Analysis of 842 Cases.
Kasem I; Mokbel K
Anticancer Res; 2020 Jul; 40(7):3633-3643. PubMed ID: 32620602
[TBL] [Abstract][Full Text] [Related]
12. Reflector-guided Localization of Non-palpable Breast Lesions: The First Reported European Evaluation of the SAVI SCOUT® System.
Tayeh S; Muktar S; Heeney J; Michell MJ; Perry N; Suaris T; Evans D; Malhotra A; Mokbel K
Anticancer Res; 2020 Jul; 40(7):3915-3924. PubMed ID: 32620632
[TBL] [Abstract][Full Text] [Related]
13. Radar-Guided Localization and Resection for Metastatic Nodal and Soft Tissue Melanoma: A Single-Institution Retrospective Study.
Beekman KE; DePalo DK; Parker LM; Elleson KM; Mullinax JE; Sarnaik AA; Sondak VK; Zager JS
Cancer Control; 2024; 31():10732748241237907. PubMed ID: 38429650
[TBL] [Abstract][Full Text] [Related]
14. Utilization of Multiple I-125 Radioactive Seeds in the Same Breast is Safe and Feasible: A Multi-institutional Experience.
Al-Hilli Z; Glazebrook KN; McLaughlin SA; Chan DM; Robinson KT; Giesbrandt JG; Slomka EL; Pizzitola VJ; Gray RJ; Jakub JW
Ann Surg Oncol; 2015 Oct; 22(10):3350-5. PubMed ID: 26219239
[TBL] [Abstract][Full Text] [Related]
15. Reflector-guided breast tumor localization versus wire localization for lumpectomies: A comparison of surgical outcomes.
Patel SN; Mango VL; Jadeja P; Friedlander L; Desperito E; Wynn R; Feldman S; Ha R
Clin Imaging; 2018; 47():14-17. PubMed ID: 28818762
[TBL] [Abstract][Full Text] [Related]
16. SCOUT® Radar Localization at Time of Breast Biopsy.
Dashevsky BZ; Muneer MS; Hao M; Liang T; Wapnir IL; Poplack SP
J Breast Imaging; 2024 May; ():. PubMed ID: 38776638
[TBL] [Abstract][Full Text] [Related]
17. Comparison of Wire and Non-Wire Localisation Techniques in Breast Cancer Surgery: A Review of the Literature with Pooled Analysis.
Shirazi S; Hajiesmaeili H; Khosla M; Taj S; Sircar T; Vidya R
Medicina (Kaunas); 2023 Jul; 59(7):. PubMed ID: 37512107
[No Abstract] [Full Text] [Related]
18. Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT
Wazir U; Kasem I; Michell MJ; Suaris T; Evans D; Malhotra A; Mokbel K
Cancers (Basel); 2021 May; 13(10):. PubMed ID: 34067552
[TBL] [Abstract][Full Text] [Related]
19. Reflector Localization of Breast Lesions and Parameters Associated with Positive Surgical Margins in Women Undergoing Breast Conservation Surgery.
Kuzmiak CM; Kim SJ; Lee SS; Jordan SG; Gallagher KK; Ollila DW; Zeng D
J Breast Imaging; 2020 Sep; 2(5):462-470. PubMed ID: 38424900
[TBL] [Abstract][Full Text] [Related]
20. Comparison of wire localization, radioactive seed, and Savi scout
Srour MK; Kim S; Amersi F; Giuliano AE; Chung A
Breast J; 2020 Mar; 26(3):406-413. PubMed ID: 31448530
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]