These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

751 related articles for article (PubMed ID: 29253631)

  • 1. Safety and accuracy of freehand versus navigated C2 pars or pedicle screw placement.
    Hlubek RJ; Bohl MA; Cole TS; Morgan CD; Xu DS; Chang SW; Turner JD; Kakarla UK
    Spine J; 2018 Aug; 18(8):1374-1381. PubMed ID: 29253631
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Freehand technique for C2 pedicle and pars screw placement: is it safe?
    Punyarat P; Buchowski JM; Klawson BT; Peters C; Lertudomphonwanit T; Riew KD
    Spine J; 2018 Jul; 18(7):1197-1203. PubMed ID: 29155344
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Increased Radiation but No Benefits in Pedicle Screw Accuracy With Navigation versus a Freehand Technique in Scoliosis Surgery.
    Urbanski W; Jurasz W; Wolanczyk M; Kulej M; Morasiewicz P; Dragan SL; Zaluski R; Miekisiak G; Dragan SF
    Clin Orthop Relat Res; 2018 May; 476(5):1020-1027. PubMed ID: 29432262
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fluoroscopy-Assisted Freehand Versus 3D-Navigated Imaging-Assisted Pedicle Screw Insertion: A Multicenter Study.
    Cammarata G; Scalia G; Costanzo R; Umana GE; Furnari M; Ponzo G; Giuffrida M; Maugeri R; Iacopino DG; Nicoletti GF; Graziano F
    Acta Neurochir Suppl; 2023; 135():425-430. PubMed ID: 38153504
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Safety and Accuracy of Anatomic and Lateral Fluoroscopic-Guided Placement of C2 Pars/Pedicle Screws and C1 Lateral Mass Screws, and Freehand Placement of C2 Laminar Screws.
    Sai Kiran NA; Sivaraju L; Vidyasagar K; Aryan S; Raj V; Rajagopal N; Mohan D; Thakar S; Rao AS; Hegde AS
    World Neurosurg; 2018 Oct; 118():e304-e315. PubMed ID: 30213379
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Risk-benefit analysis of navigation techniques for vertebral transpedicular instrumentation: a prospective study.
    Noriega DC; Hernández-Ramajo R; Rodríguez-Monsalve Milano F; Sanchez-Lite I; Toribio B; Ardura F; Torres R; Corredera R; Kruger A
    Spine J; 2017 Jan; 17(1):70-75. PubMed ID: 27503262
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Percutaneous pedicle screw placement under single dimensional fluoroscopy with a designed pedicle finder-a technical note and case series.
    Tsuang FY; Chen CH; Kuo YJ; Tseng WL; Chen YS; Lin CJ; Liao CJ; Lin FH; Chiang CJ
    Spine J; 2017 Sep; 17(9):1373-1380. PubMed ID: 28645672
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of C2 pedicle screw placement via the freehand technique by neurosurgical trainees.
    Pham MH; Bakhsheshian J; Reid PC; Buchanan IA; Fredrickson VL; Liu JC
    J Neurosurg Spine; 2018 Sep; 29(3):235-240. PubMed ID: 29882714
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Safety and Accuracy of Freehand Versus Navigated Iliac Screws: Results From 222 Screw Placements.
    Hlubek RJ; Almefty KK; Xu DS; Turner JD; Kakarla UK
    Spine (Phila Pa 1976); 2017 Oct; 42(20):E1190-E1196. PubMed ID: 28230623
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery.
    Molliqaj G; Schatlo B; Alaid A; Solomiichuk V; Rohde V; Schaller K; Tessitore E
    Neurosurg Focus; 2017 May; 42(5):E14. PubMed ID: 28463623
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Robotic and navigated pedicle screws are safer and more accurate than fluoroscopic freehand screws: a systematic review and meta-analysis.
    Matur AV; Palmisciano P; Duah HO; Chilakapati SS; Cheng JS; Adogwa O
    Spine J; 2023 Feb; 23(2):197-208. PubMed ID: 36273761
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Preliminary experience with a novel facet-based lateral mass drill guide for the placement of lateral mass screws compared to freehand technique: a cadaveric study.
    Mundis GM; Olsson EC; Hart RA; Williams SK; Martyn R; Orndorff DG; Berg AL; Russell NA; Vizesi F
    Spine J; 2023 Jun; 23(6):912-920. PubMed ID: 36736741
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Freehand C2 Pedicle Screw Placement: Surgical Anatomy and Operative Technique.
    Clifton W; Vlasak A; Damon A; Dove C; Pichelmann M
    World Neurosurg; 2019 Dec; 132():113. PubMed ID: 31493597
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of fluoroscopically-assisted pedicle screw placement: analysis of 1,218 screws in 198 patients.
    Koktekir E; Ceylan D; Tatarli N; Karabagli H; Recber F; Akdemir G
    Spine J; 2014 Aug; 14(8):1702-8. PubMed ID: 24704680
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intraoperative Computed Tomography-Guided Navigation for Pediatric Spine Patients Reduced Return to Operating Room for Screw Malposition Compared With Freehand/Fluoroscopic Techniques.
    Baky FJ; Milbrandt T; Echternacht S; Stans AA; Shaughnessy WJ; Larson AN
    Spine Deform; 2019 Jul; 7(4):577-581. PubMed ID: 31202374
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of intraoperative CT- and cone beam CT-based spinal navigation for the treatment of atlantoaxial instability.
    Haemmerli J; Ferdowssian K; Wessels L; Mertens R; Hecht N; Woitzik J; Schneider UC; Bayerl SH; Vajkoczy P; Czabanka M
    Spine J; 2023 Dec; 23(12):1799-1807. PubMed ID: 37619869
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis.
    Azimi P; Yazdanian T; Benzel EC; Aghaei HN; Azhari S; Sadeghi S; Montazeri A
    J Orthop Surg Res; 2020 Jul; 15(1):272. PubMed ID: 32690035
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does Navigation Improve Pedicle Screw Placement Accuracy? Comparison Between Navigated and Non-navigated Percutaneous and Open Fixations.
    Innocenzi G; Bistazzoni S; D'Ercole M; Cardarelli G; Ricciardi F
    Acta Neurochir Suppl; 2017; 124():289-295. PubMed ID: 28120086
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Incidence of lumbar spine pedicle breach after percutaneous screw fixation: a radiographic evaluation of 601 screws in 151 patients.
    Smith ZA; Sugimoto K; Lawton CD; Fessler RG
    J Spinal Disord Tech; 2014 Oct; 27(7):358-63. PubMed ID: 22688617
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of freehand pedicle screws versus lateral mass screws in the subaxial cervical spine.
    Hey HWD; Zhuo WH; Tan YHJ; Tan JH
    Spine Deform; 2020 Oct; 8(5):1049-1058. PubMed ID: 32314180
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 38.