These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
192 related articles for article (PubMed ID: 2926462)
1. Evaluation of the palmar circulation by pulse oximetry. Cheng EY; Lauer KK; Stommel KA; Guenther NR J Clin Monit; 1989 Jan; 5(1):1-3. PubMed ID: 2926462 [TBL] [Abstract][Full Text] [Related]
2. Evaluation of collateral circulation of the hand. Fuhrman TM; Pippin WD; Talmage LA; Reilley TE J Clin Monit; 1992 Jan; 8(1):28-32. PubMed ID: 1538249 [TBL] [Abstract][Full Text] [Related]
3. The Allen's test: analysis of four methods. Levinsohn DG; Gordon L; Sessler DI J Hand Surg Am; 1991 Mar; 16(2):279-82. PubMed ID: 2022838 [TBL] [Abstract][Full Text] [Related]
4. Allen's test and systolic arterial pressure in the thumb. Husum B; Berthelsen P Br J Anaesth; 1981 Jun; 53(6):635-7. PubMed ID: 7248127 [TBL] [Abstract][Full Text] [Related]
5. [Evaluation of palmar collateral circulation with the Oxygenmet oxygen saturation measurement device]. Bechstein WO; Schaps DK; Kirchner E Anasth Intensivther Notfallmed; 1984 Dec; 19(6):312-3. PubMed ID: 6524642 [TBL] [Abstract][Full Text] [Related]
6. Noninvasive evaluation of hand circulation before radial artery harvest for coronary artery bypass grafting. Starnes SL; Wolk SW; Lampman RM; Shanley CJ; Prager RL; Kong BK; Fowler JJ; Page JM; Babcock SL; Lange LA; Erlandson EE; Whitehouse WM J Thorac Cardiovasc Surg; 1999 Feb; 117(2):261-6. PubMed ID: 9918966 [TBL] [Abstract][Full Text] [Related]
7. Noninvasive evaluation of the collateral circulation to the hand. Fuhrman TM; McSweeney E Acad Emerg Med; 1995 Mar; 2(3):195-9. PubMed ID: 7497033 [TBL] [Abstract][Full Text] [Related]
8. Reliability of Allen's test in selection of patients for radial artery harvest. Jarvis MA; Jarvis CL; Jones PR; Spyt TJ Ann Thorac Surg; 2000 Oct; 70(4):1362-5. PubMed ID: 11081899 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of the ulnopalmar arterial arches with pulse oximetry and plethysmography: comparison with the Allen's test in 1010 patients. Barbeau GR; Arsenault F; Dugas L; Simard S; Larivière MM Am Heart J; 2004 Mar; 147(3):489-93. PubMed ID: 14999199 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of Allen's test in both arms and arteries of left and right-handed people. Oettlé AC; van Niekerk A; Boon JM; Meiring JH Surg Radiol Anat; 2006 Mar; 28(1):3-6. PubMed ID: 16456619 [TBL] [Abstract][Full Text] [Related]
11. Assessment of digital blood flow and palmar collateral circulation. Allen's test vs. photoplethysmography. Stead SW; Stirt JA Int J Clin Monit Comput; 1985; 2(1):29-34. PubMed ID: 3835222 [TBL] [Abstract][Full Text] [Related]
12. Can the modified Allen's test always detect sufficient collateral flow in the hand? A computational study. Alastruey J; Parker KH; Peiró J; Sherwin SJ Comput Methods Biomech Biomed Engin; 2006 Dec; 9(6):353-61. PubMed ID: 17145669 [TBL] [Abstract][Full Text] [Related]
13. Pulse oximetry compared with Doppler ultrasound for assessment of collateral blood flow to the hand. Pillow K; Herrick IA Anaesthesia; 1991 May; 46(5):388-90. PubMed ID: 2035789 [TBL] [Abstract][Full Text] [Related]
14. Comparison of digital blood pressure, plethysmography, and the modified Allen's test as means of evaluating the collateral circulation to the hand. Fuhrman TM; Reilley TE; Pippin WD Anaesthesia; 1992 Nov; 47(11):959-61. PubMed ID: 1466436 [TBL] [Abstract][Full Text] [Related]
15. On the safety of radial artery cannulation. Slogoff S; Keats AS; Arlund C Anesthesiology; 1983 Jul; 59(1):42-7. PubMed ID: 6859611 [TBL] [Abstract][Full Text] [Related]
16. Assessment of collateral hand circulation by modified Allen's test in normal Indian subjects. Agarwal T; Agarwal V; Agarwal P; Thakur S; Bobba R; Sharma D J Clin Orthop Trauma; 2020; 11(4):626-629. PubMed ID: 32684700 [TBL] [Abstract][Full Text] [Related]
18. [Doppler velocimetric evaluation of the reliability of Allen's test for radial artery catheterization]. Marcillon M; Maestracci P; Guillot F; Dulbecco P; Filippi C; Valici A Ann Fr Anesth Reanim; 1982; 1(4):403-6. PubMed ID: 7171137 [TBL] [Abstract][Full Text] [Related]
19. Assessment of collateral circulation to the hand prior to radial artery harvest. Habib J; Baetz L; Satiani B Vasc Med; 2012 Oct; 17(5):352-61. PubMed ID: 22814998 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of a postocclusive reactive circulatory hyperaemia (PORCH) test for the assessment of ulnar collateral circulation. Vaghadia H; Schechter MT; Sheps SB; Jenkins LC Can J Anaesth; 1988 Nov; 35(6):591-8. PubMed ID: 3060281 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]