217 related articles for article (PubMed ID: 29275098)
1. Breast lesion classification based on supersonic shear-wave elastography and automated lesion segmentation from B-mode ultrasound images.
Yu Y; Xiao Y; Cheng J; Chiu B
Comput Biol Med; 2018 Feb; 93():31-46. PubMed ID: 29275098
[TBL] [Abstract][Full Text] [Related]
2. Computer-aided diagnosis based on quantitative elastographic features with supersonic shear wave imaging.
Xiao Y; Zeng J; Niu L; Zeng Q; Wu T; Wang C; Zheng R; Zheng H
Ultrasound Med Biol; 2014 Feb; 40(2):275-86. PubMed ID: 24268454
[TBL] [Abstract][Full Text] [Related]
3. Ultrasound Shear Wave Elastography for Liver Disease. A Critical Appraisal of the Many Actors on the Stage.
Piscaglia F; Salvatore V; Mulazzani L; Cantisani V; Schiavone C
Ultraschall Med; 2016 Feb; 37(1):1-5. PubMed ID: 26871407
[TBL] [Abstract][Full Text] [Related]
4. Comparison and Combination of Strain and Shear Wave Elastography of Breast Masses for Differentiation of Benign and Malignant Lesions by Quantitative Assessment: Preliminary Study.
Seo M; Ahn HS; Park SH; Lee JB; Choi BI; Sohn YM; Shin SY
J Ultrasound Med; 2018 Jan; 37(1):99-109. PubMed ID: 28688156
[TBL] [Abstract][Full Text] [Related]
5. Quantitative evaluation of peripheral tissue elasticity for ultrasound-detected breast lesions.
Xiao Y; Yu Y; Niu L; Qian M; Deng Z; Qiu W; Zheng H
Clin Radiol; 2016 Sep; 71(9):896-904. PubMed ID: 27349474
[TBL] [Abstract][Full Text] [Related]
6. Comparison of 3D and 2D shear-wave elastography for differentiating benign and malignant breast masses: focus on the diagnostic performance.
Choi HY; Sohn YM; Seo M
Clin Radiol; 2017 Oct; 72(10):878-886. PubMed ID: 28526455
[TBL] [Abstract][Full Text] [Related]
7. Evaluating different combination methods to analyse ultrasound and shear wave elastography images automatically through discriminative convolutional neural network in breast cancer imaging.
Hoffmann R; Reich C; Skerl K
Int J Comput Assist Radiol Surg; 2022 Dec; 17(12):2231-2237. PubMed ID: 36018397
[TBL] [Abstract][Full Text] [Related]
8. Quantification of elastic heterogeneity using contourlet-based texture analysis in shear-wave elastography for breast tumor classification.
Zhang Q; Xiao Y; Chen S; Wang C; Zheng H
Ultrasound Med Biol; 2015 Feb; 41(2):588-600. PubMed ID: 25444693
[TBL] [Abstract][Full Text] [Related]
9. Shear Wave Elastography (SWE): An Analysis of Breast Lesion Characterization in 83 Breast Lesions.
Feldmann A; Langlois C; Dewailly M; Martinez EF; Boulanger L; Kerdraon O; Faye N
Ultrasound Med Biol; 2015 Oct; 41(10):2594-604. PubMed ID: 26159068
[TBL] [Abstract][Full Text] [Related]
10. Added value of Virtual Touch IQ shear wave elastography in the ultrasound assessment of breast lesions.
Ianculescu V; Ciolovan LM; Dunant A; Vielh P; Mazouni C; Delaloge S; Dromain C; Blidaru A; Balleyguier C
Eur J Radiol; 2014 May; 83(5):773-7. PubMed ID: 24602803
[TBL] [Abstract][Full Text] [Related]
11. Ultrasound Strain Elastography for Breast Lesions: Computer-Aided Evaluation With Quantifiable Elastographic Features.
Xiao Y; Zeng J; Zhang X; Niu LL; Qian M; Wang CZ; Zheng HR; Zheng RQ
J Ultrasound Med; 2017 Jun; 36(6):1089-1100. PubMed ID: 28295467
[TBL] [Abstract][Full Text] [Related]
12. Diagnostic performances of shear-wave elastography and B-mode ultrasound to differentiate benign and malignant breast lesions: the emphasis on the cutoff value of qualitative and quantitative parameters.
Song EJ; Sohn YM; Seo M
Clin Imaging; 2018; 50():302-307. PubMed ID: 29751202
[TBL] [Abstract][Full Text] [Related]
13. Semi-quantitative and qualitative assessment of breast ultrasound elastography in differentiating between malignant and benign lesions.
Alhabshi SM; Rahmat K; Abdul Halim N; Aziz S; Radhika S; Gan GC; Vijayananthan A; Westerhout CJ; Mohd-Shah MN; Jaszle S; Harlina Mohd Latar N; Muhammad R
Ultrasound Med Biol; 2013 Apr; 39(4):568-78. PubMed ID: 23384468
[TBL] [Abstract][Full Text] [Related]
14. Dual-mode artificially-intelligent diagnosis of breast tumours in shear-wave elastography and B-mode ultrasound using deep polynomial networks.
Zhang Q; Song S; Xiao Y; Chen S; Shi J; Zheng H
Med Eng Phys; 2019 Feb; 64():1-6. PubMed ID: 30578163
[TBL] [Abstract][Full Text] [Related]
15. A Machine-Learning Algorithm Toward Color Analysis for Chronic Liver Disease Classification, Employing Ultrasound Shear Wave Elastography.
Gatos I; Tsantis S; Spiliopoulos S; Karnabatidis D; Theotokas I; Zoumpoulis P; Loupas T; Hazle JD; Kagadis GC
Ultrasound Med Biol; 2017 Sep; 43(9):1797-1810. PubMed ID: 28634041
[TBL] [Abstract][Full Text] [Related]
16. Role of "Stiff Rim" sign obtained by shear wave elastography in diagnosis and guiding therapy of breast cancer.
Xu YJ; Gong HL; Hu B; Hu B
Int J Med Sci; 2021; 18(15):3615-3623. PubMed ID: 34522189
[No Abstract] [Full Text] [Related]
17. Computer-aided tumor diagnosis using shear wave breast elastography.
Moon WK; Huang YS; Lee YW; Chang SC; Lo CM; Yang MC; Bae MS; Lee SH; Chang JM; Huang CS; Lin YT; Chang RF
Ultrasonics; 2017 Jul; 78():125-133. PubMed ID: 28342323
[TBL] [Abstract][Full Text] [Related]
18. Shear wave elastography for characterization of breast lesions: Shearlet transform and local binary pattern histogram techniques.
Acharya UR; Ng WL; Rahmat K; Sudarshan VK; Koh JEW; Tan JH; Hagiwara Y; Gertych A; Fadzli F; Yeong CH; Ng KH
Comput Biol Med; 2017 Dec; 91():13-20. PubMed ID: 29031099
[TBL] [Abstract][Full Text] [Related]
19. Image Processing Pipeline for Liver Fibrosis Classification Using Ultrasound Shear Wave Elastography.
Brattain LJ; Ozturk A; Telfer BA; Dhyani M; Grajo JR; Samir AE
Ultrasound Med Biol; 2020 Oct; 46(10):2667-2676. PubMed ID: 32622685
[TBL] [Abstract][Full Text] [Related]
20. Comparison of strain and shear wave elastography for the differentiation of benign from malignant breast lesions, combined with B-mode ultrasonography: qualitative and quantitative assessments.
Youk JH; Son EJ; Gweon HM; Kim H; Park YJ; Kim JA
Ultrasound Med Biol; 2014 Oct; 40(10):2336-44. PubMed ID: 25130444
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]