These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
329 related articles for article (PubMed ID: 29303068)
1. Soft Robotic Manipulator for Improving Dexterity in Minimally Invasive Surgery. Diodato A; Brancadoro M; De Rossi G; Abidi H; Dall'Alba D; Muradore R; Ciuti G; Fiorini P; Menciassi A; Cianchetti M Surg Innov; 2018 Feb; 25(1):69-76. PubMed ID: 29303068 [TBL] [Abstract][Full Text] [Related]
2. A bioinspired soft manipulator for minimally invasive surgery. Ranzani T; Gerboni G; Cianchetti M; Menciassi A Bioinspir Biomim; 2015 May; 10(3):035008. PubMed ID: 25970550 [TBL] [Abstract][Full Text] [Related]
3. A soft multi-module manipulator with variable stiffness for minimally invasive surgery. De Falco I; Cianchetti M; Menciassi A Bioinspir Biomim; 2017 Sep; 12(5):056008. PubMed ID: 28675144 [TBL] [Abstract][Full Text] [Related]
4. Hamlyn CRM: a compact master manipulator for surgical robot remote control. Zhang D; Liu J; Zhang L; Yang GZ Int J Comput Assist Radiol Surg; 2020 Mar; 15(3):503-514. PubMed ID: 31956954 [TBL] [Abstract][Full Text] [Related]
5. Development of stereo endoscope system with its innovative master interface for continuous surgical operation. Kim M; Lee C; Hong N; Kim YJ; Kim S Biomed Eng Online; 2017 Jun; 16(1):81. PubMed ID: 28646865 [TBL] [Abstract][Full Text] [Related]
6. Highly dexterous 2-module soft robot for intra-organ navigation in minimally invasive surgery. Abidi H; Gerboni G; Brancadoro M; Fras J; Diodato A; Cianchetti M; Wurdemann H; Althoefer K; Menciassi A Int J Med Robot; 2018 Feb; 14(1):. PubMed ID: 29205769 [TBL] [Abstract][Full Text] [Related]
7. The i Berthet-Rayne P; Gras G; Leibrandt K; Wisanuvej P; Schmitz A; Seneci CA; Yang GZ Ann Biomed Eng; 2018 Oct; 46(10):1663-1675. PubMed ID: 29948372 [TBL] [Abstract][Full Text] [Related]
8. A review on recent advances in soft surgical robots for endoscopic applications. Gifari MW; Naghibi H; Stramigioli S; Abayazid M Int J Med Robot; 2019 Oct; 15(5):e2010. PubMed ID: 31069938 [TBL] [Abstract][Full Text] [Related]
9. A Temperature-Dependent, Variable-Stiffness Endoscopic Robotic Manipulator with Active Heating and Cooling. Le HM; Phan PT; Lin C; Jiajun L; Phee SJ Ann Biomed Eng; 2020 Jun; 48(6):1837-1849. PubMed ID: 32232695 [TBL] [Abstract][Full Text] [Related]
10. K-FLEX: A flexible robotic platform for scar-free endoscopic surgery. Hwang M; Kwon DS Int J Med Robot; 2020 Apr; 16(2):e2078. PubMed ID: 31945797 [TBL] [Abstract][Full Text] [Related]
11. Master manipulator optimisation for robot assisted minimally invasive surgery. Feng M; Ni ZX; Li A; Lu X; Fu YL Int J Med Robot; 2021 Apr; 17(2):e2208. PubMed ID: 33345436 [TBL] [Abstract][Full Text] [Related]
12. Chip-on-tip endoscope incorporating a soft robotic pneumatic bending microactuator. Gorissen B; De Volder M; Reynaerts D Biomed Microdevices; 2018 Aug; 20(3):73. PubMed ID: 30105633 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of long-term stability of monolithic 3D-printed robotic manipulator structures for minimally invasive surgery. Krieger YS; Ostler D; Rzepka K; Meining A; Feussner H; Wilhelm D; Lueth TC Int J Comput Assist Radiol Surg; 2020 Oct; 15(10):1693-1697. PubMed ID: 32789728 [TBL] [Abstract][Full Text] [Related]
14. Head-mounted interface for intuitive vision control and continuous surgical operation in a surgical robot system. Hong N; Kim M; Lee C; Kim S Med Biol Eng Comput; 2019 Mar; 57(3):601-614. PubMed ID: 30280331 [TBL] [Abstract][Full Text] [Related]
15. The Minimally Invasive Manipulator: an ergonomic and economic non-robotic alternative for endoscopy? Bosma J; Aarts S; Jaspers J Minim Invasive Ther Allied Technol; 2015 Feb; 24(1):24-30. PubMed ID: 25627434 [TBL] [Abstract][Full Text] [Related]
16. A novel microwave tool for robotic liver resection in minimally invasive surgery. Brancadoro M; Dimitri M; Boushaki MN; Staderini F; Sinibaldi E; Capineri L; Cianchi F; Biffi Gentili G; Menciassi A Minim Invasive Ther Allied Technol; 2022 Jan; 31(1):42-49. PubMed ID: 32255393 [TBL] [Abstract][Full Text] [Related]
17. A cable-driven soft robot surgical system for cardiothoracic endoscopic surgery: preclinical tests in animals. Wang H; Zhang R; Chen W; Wang X; Pfeifer R Surg Endosc; 2017 Aug; 31(8):3152-3158. PubMed ID: 27858208 [TBL] [Abstract][Full Text] [Related]
18. A Novel Telemanipulated Robotic Assistant for Surgical Endoscopy: Preclinical Application to ESD. Zorn L; Nageotte F; Zanne P; Legner A; Dallemagne B; Marescaux J; de Mathelin M IEEE Trans Biomed Eng; 2018 Apr; 65(4):797-808. PubMed ID: 28678698 [TBL] [Abstract][Full Text] [Related]
19. Design of a new haptic device and experiments in minimally invasive surgical robot. Wang T; Pan B; Fu Y; Wang S; Ai Y Comput Assist Surg (Abingdon); 2017 Dec; 22(sup1):240-250. PubMed ID: 29072504 [TBL] [Abstract][Full Text] [Related]
20. Robot-assisted Sistrunk's operation, total thyroidectomy, and neck dissection via a transaxillary and retroauricular (TARA) approach in papillary carcinoma arising in thyroglossal duct cyst and thyroid gland. Byeon HK; Ban MJ; Lee JM; Ha JG; Kim ES; Koh YW; Choi EC Ann Surg Oncol; 2012 Dec; 19(13):4259-61. PubMed ID: 23070784 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]