546 related articles for article (PubMed ID: 29305100)
1. Clinical outcomes of minimally invasive open reduction and internal fixation by screw and washer for displaced greater tuberosity fracture of the humerus.
Yoon TH; Choi CH; Choi YR; Oh JT; Chun YM
J Shoulder Elbow Surg; 2018 Jun; 27(6):e173-e177. PubMed ID: 29305100
[TBL] [Abstract][Full Text] [Related]
2. Is Arthroscopic Technique Superior to Open Reduction Internal Fixation in the Treatment of Isolated Displaced Greater Tuberosity Fractures?
Liao W; Zhang H; Li Z; Li J
Clin Orthop Relat Res; 2016 May; 474(5):1269-79. PubMed ID: 26728514
[TBL] [Abstract][Full Text] [Related]
3. [ARTHROSCOPOIC FIXATION WITH PERCUTANEOUS CANNULATED SCREWS FOR ACUTE DISPLACED ISOLATED GREATER TUBEROSITY FRACTURES OF THE PROXIMAL HUMERUS].
Xi Z; Liang Q; Mi K; Feng Z; Wang B
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2015 Jan; 29(1):1-5. PubMed ID: 26455161
[TBL] [Abstract][Full Text] [Related]
4. Proximal periarticular locking plates in proximal humeral fractures: functional outcomes.
Schulte LM; Matteini LE; Neviaser RJ
J Shoulder Elbow Surg; 2011 Dec; 20(8):1234-40. PubMed ID: 21420322
[TBL] [Abstract][Full Text] [Related]
5. A new low-profile anatomic locking plate for fixation of comminuted, displaced greater tuberosity fractures of the proximal humerus.
Zeng LQ; Chen YF; Jiang YW; Zeng LL; Miao XG; Liang WG
J Shoulder Elbow Surg; 2021 Jun; 30(6):1402-1409. PubMed ID: 32949759
[TBL] [Abstract][Full Text] [Related]
6. Minimally Invasive Plate Osteosynthesis Using a Screw Compression Method for Treatment of Humeral Shaft Fractures.
Ko SH; Cha JR; Lee CC; Joo YT; Eom KS
Clin Orthop Surg; 2017 Dec; 9(4):506-513. PubMed ID: 29201304
[TBL] [Abstract][Full Text] [Related]
7. Open Reduction and Stable Internal Fixation Using a 3.5-mm Locking Hook Plate for Isolated Fractures of the Greater Tuberosity of the Humerus: A 2-Year Follow-up Study Using an Innovative Fixation Method.
Lee WY; Shin HD; Kim KC; Cha SM; Jeon YS; Kim DH
Clin Orthop Surg; 2021 Sep; 13(3):293-300. PubMed ID: 34484620
[TBL] [Abstract][Full Text] [Related]
8. Minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS).
Brunner A; Thormann S; Babst R
J Shoulder Elbow Surg; 2012 Aug; 21(8):1056-63. PubMed ID: 21872493
[TBL] [Abstract][Full Text] [Related]
9. Displaced fractures of the greater tuberosity: a comparison of operative and nonoperative treatment.
Platzer P; Thalhammer G; Oberleitner G; Kutscha-Lissberg F; Wieland T; Vecsei V; Gaebler C
J Trauma; 2008 Oct; 65(4):843-8. PubMed ID: 18349710
[TBL] [Abstract][Full Text] [Related]
10. Three- and 4-part proximal humeral fracture fixation with an intramedullary cage: 1-year clinical and radiographic outcomes.
Hudgens JL; Jang J; Aziz K; Best MJ; Srikumaran U
J Shoulder Elbow Surg; 2019 Jun; 28(6S):S131-S137. PubMed ID: 31196507
[TBL] [Abstract][Full Text] [Related]
11. Closed reduction and minimally invasive percutaneous fixation of proximal humerus fractures using the Humerusblock.
Brunner A; Weller K; Thormann S; Jöckel JA; Babst R
J Orthop Trauma; 2010 Jul; 24(7):407-13. PubMed ID: 20577070
[TBL] [Abstract][Full Text] [Related]
12. Functional outcomes for surgically treated 3- and 4-part proximal humerus fractures.
Wild JR; DeMers A; French R; Shipps MR; Bergin PF; Musapatika D; Jelen BA
Orthopedics; 2011 Oct; 34(10):e629-33. PubMed ID: 21956057
[TBL] [Abstract][Full Text] [Related]
13. Arthroscopic fixation technique for comminuted, displaced greater tuberosity fracture.
Ji JH; Shafi M; Song IS; Kim YY; McFarland EG; Moon CY
Arthroscopy; 2010 May; 26(5):600-9. PubMed ID: 20434656
[TBL] [Abstract][Full Text] [Related]
14. Is minimally invasive plate osteosynthesis superior to open plating for fixation of two-part fracture of the proximal humerus?
Kim YG; Park KH; Kim JW; Oh JK; Yoon JP; Kim HJ; Oh CW
J Orthop Surg (Hong Kong); 2019; 27(2):2309499019836156. PubMed ID: 30885047
[TBL] [Abstract][Full Text] [Related]
15. Open reduction and fixation with a locking plate without bone grafting is a reasonable and safe option for treating proximal humerus nonunion.
Quadlbauer S; Hofmann GJ; Leixnering M; Rosenauer R; Hausner T; Reichetseder J
Int Orthop; 2018 Sep; 42(9):2199-2209. PubMed ID: 29442159
[TBL] [Abstract][Full Text] [Related]
16. Using Plate Osteosynthesis to Treat Isolated Greater Tuberosity Fractures.
Gillespie RJ; Johnston PS; Gordon VA; Ward PJ; Getz CL
Am J Orthop (Belle Mead NJ); 2015 Aug; 44(8):E248-51. PubMed ID: 26251938
[TBL] [Abstract][Full Text] [Related]
17. Arthroscopic reduction and fixation of greater tuberosity fractures of the humerus.
Kokkalis ZT; Papanikos E; Bavelou E; Togias G; Sioutis S; Mavrogenis AF; Panagopoulos A
Eur J Orthop Surg Traumatol; 2021 Aug; 31(6):1055-1060. PubMed ID: 33387054
[TBL] [Abstract][Full Text] [Related]
18. [Comparison of curative effects between minimally invasive locking plate internal fixation and open reduction with internal fixation for the treatment of proximal humerus fractures].
Shang LP; Zhou F; Ji HQ; Zhang ZS; Liu XG; Tian Y
Beijing Da Xue Xue Bao Yi Xue Ban; 2013 Oct; 45(5):711-6. PubMed ID: 24136264
[TBL] [Abstract][Full Text] [Related]
19. [Comparison of effectiveness between minimally invasive cannulated screw and open reduction and plate fixation in treatment of humeral greater tuberosity fracture].
Cao L; Weng W; Song S; Li H; Su J
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Apr; 27(4):418-22. PubMed ID: 23757867
[TBL] [Abstract][Full Text] [Related]
20. Shoulder arthroscopy combined to hardware removal in proximal humeral fractures: a series of 58 cases with a mean follow-up of 2 years.
Maroun C; Aliani D; Hass A; Werthel JD; Vidil A; Valenti P
Eur J Orthop Surg Traumatol; 2017 Apr; 27(3):317-321. PubMed ID: 28289904
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]