340 related articles for article (PubMed ID: 29305441)
1. Automated real-time detection of tonic-clonic seizures using a wearable EMG device.
Beniczky S; Conradsen I; Henning O; Fabricius M; Wolf P
Neurology; 2018 Jan; 90(5):e428-e434. PubMed ID: 29305441
[TBL] [Abstract][Full Text] [Related]
2. Electromyography-based seizure detector: Preliminary results comparing a generalized tonic-clonic seizure detection algorithm to video-EEG recordings.
Szabó CÁ; Morgan LC; Karkar KM; Leary LD; Lie OV; Girouard M; Cavazos JE
Epilepsia; 2015 Sep; 56(9):1432-7. PubMed ID: 26190150
[TBL] [Abstract][Full Text] [Related]
3. Seizure detection based on heart rate variability using a wearable electrocardiography device.
Jeppesen J; Fuglsang-Frederiksen A; Johansen P; Christensen J; Wüstenhagen S; Tankisi H; Qerama E; Hess A; Beniczky S
Epilepsia; 2019 Oct; 60(10):2105-2113. PubMed ID: 31538347
[TBL] [Abstract][Full Text] [Related]
4. Detection of generalized tonic-clonic seizures from ear-EEG based on EMG analysis.
Zibrandtsen IC; Kidmose P; Kjaer TW
Seizure; 2018 Jul; 59():54-59. PubMed ID: 29747022
[TBL] [Abstract][Full Text] [Related]
5. Automated Detection of Convulsive Seizures Using a Wearable Accelerometer Device.
Kusmakar S; Karmakar C; Yan B; Obrien T; Muthuganapathy R; Palaniswami M
IEEE Trans Biomed Eng; 2019 Feb; 66(2):421-432. PubMed ID: 29993501
[TBL] [Abstract][Full Text] [Related]
6. Detection of generalized tonic-clonic seizures by a wireless wrist accelerometer: a prospective, multicenter study.
Beniczky S; Polster T; Kjaer TW; Hjalgrim H
Epilepsia; 2013 Apr; 54(4):e58-61. PubMed ID: 23398578
[TBL] [Abstract][Full Text] [Related]
7. Multimodal wearable EEG, EMG and accelerometry measurements improve the accuracy of tonic-clonic seizure detection.
Zhang J; Swinnen L; Chatzichristos C; Broux V; Proost R; Jansen K; Mahler B; Zabler N; Epitashvilli N; Dümpelmann M; Schulze-Bonhage A; Schriewer E; Ermis U; Wolking S; Linke F; Weber Y; Symmonds M; Sen A; Biondi A; Richardson MP; I AS; Silva AI; Sales F; Vértes G; Paesschen WV; Vos M
Physiol Meas; 2024 Jun; 45(6):. PubMed ID: 38772401
[No Abstract] [Full Text] [Related]
8. Multimodal wrist-worn devices for seizure detection and advancing research: Focus on the Empatica wristbands.
Regalia G; Onorati F; Lai M; Caborni C; Picard RW
Epilepsy Res; 2019 Jul; 153():79-82. PubMed ID: 30846346
[TBL] [Abstract][Full Text] [Related]
9. Quantitative analysis of surface electromyography during epileptic and nonepileptic convulsive seizures.
Beniczky S; Conradsen I; Moldovan M; Jennum P; Fabricius M; Benedek K; Andersen N; Hjalgrim H; Wolf P
Epilepsia; 2014 Jul; 55(7):1128-34. PubMed ID: 24889069
[TBL] [Abstract][Full Text] [Related]
10. Are Seizure Detection Devices Ready for Prime Time?
Van Ness PC
Epilepsy Curr; 2019 Jan; 19(1):36-37. PubMed ID: 30838924
[TBL] [Abstract][Full Text] [Related]
11. Tonic-clonic seizure detection using accelerometry-based wearable sensors: A prospective, video-EEG controlled study.
Johansson D; Ohlsson F; Krýsl D; Rydenhag B; Czarnecki M; Gustafsson N; Wipenmyr J; McKelvey T; Malmgren K
Seizure; 2019 Feb; 65():48-54. PubMed ID: 30611010
[TBL] [Abstract][Full Text] [Related]
12. Ictal quantitative surface electromyography correlates with postictal EEG suppression.
Arbune AA; Conradsen I; Cardenas DP; Whitmire LE; Voyles SR; Wolf P; Lhatoo S; Ryvlin P; Beniczky S
Neurology; 2020 Jun; 94(24):e2567-e2576. PubMed ID: 32398358
[TBL] [Abstract][Full Text] [Related]
13. Automated algorithm for generalized tonic-clonic epileptic seizure onset detection based on sEMG zero-crossing rate.
Conradsen I; Beniczky S; Hoppe K; Wolf P; Sorensen HB
IEEE Trans Biomed Eng; 2012 Feb; 59(2):579-85. PubMed ID: 22156944
[TBL] [Abstract][Full Text] [Related]
14. Automated seizure detection using wearable devices: A clinical practice guideline of the International League Against Epilepsy and the International Federation of Clinical Neurophysiology.
Beniczky S; Wiebe S; Jeppesen J; Tatum WO; Brazdil M; Wang Y; Herman ST; Ryvlin P
Epilepsia; 2021 Mar; 62(3):632-646. PubMed ID: 33666944
[TBL] [Abstract][Full Text] [Related]
15. Visual seizure annotation and automated seizure detection using behind-the-ear electroencephalographic channels.
Vandecasteele K; De Cooman T; Dan J; Cleeren E; Van Huffel S; Hunyadi B; Van Paesschen W
Epilepsia; 2020 Apr; 61(4):766-775. PubMed ID: 32160324
[TBL] [Abstract][Full Text] [Related]
16. User-based evaluation of applicability and usability of a wearable accelerometer device for detecting bilateral tonic-clonic seizures: A field study.
Meritam P; Ryvlin P; Beniczky S
Epilepsia; 2018 Jun; 59 Suppl 1():48-52. PubMed ID: 29873828
[TBL] [Abstract][Full Text] [Related]
17. Automated video-based detection of nocturnal convulsive seizures in a residential care setting.
Geertsema EE; Thijs RD; Gutter T; Vledder B; Arends JB; Leijten FS; Visser GH; Kalitzin SN
Epilepsia; 2018 Jun; 59 Suppl 1():53-60. PubMed ID: 29638008
[TBL] [Abstract][Full Text] [Related]
18. Quantitative analysis of surface electromyography: Biomarkers for convulsive seizures.
Beniczky S; Conradsen I; Pressler R; Wolf P
Clin Neurophysiol; 2016 Aug; 127(8):2900-2907. PubMed ID: 27212115
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of novel algorithm embedded in a wearable sEMG device for seizure detection.
Conradsen I; Beniczky S; Wolf P; Jennum P; Sorensen HB
Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():2048-51. PubMed ID: 23366322
[TBL] [Abstract][Full Text] [Related]
20. Detection of convulsive seizures using surface electromyography.
Beniczky S; Conradsen I; Wolf P
Epilepsia; 2018 Jun; 59 Suppl 1():23-29. PubMed ID: 29873829
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]