298 related articles for article (PubMed ID: 29307456)
1. Impact of Annular Size on Outcomes After Surgical or Transcatheter Aortic Valve Replacement.
Deeb GM; Chetcuti SJ; Yakubov SJ; Patel HJ; Grossman PM; Kleiman NS; Heiser J; Merhi W; Zorn GL; Tadros PN; Petrossian G; Robinson N; Mumtaz M; Gleason TG; Huang J; Conte JV; Popma JJ; Reardon MJ
Ann Thorac Surg; 2018 Apr; 105(4):1129-1136. PubMed ID: 29307456
[TBL] [Abstract][Full Text] [Related]
2. Computed Tomography-Based Indexed Aortic Annulus Size to Predict Prosthesis-Patient Mismatch.
Head SJ; Reardon MJ; Deeb GM; Van Mieghem NM; Popma JJ; Gleason TG; Williams MR; Radhakrishnan S; Fremes S; Oh JK; Chang Y; Boulware MJ; Kappetein AP
Circ Cardiovasc Interv; 2019 Apr; 12(4):e007396. PubMed ID: 30929507
[TBL] [Abstract][Full Text] [Related]
3. Prosthesis-patient mismatch in high-risk patients with severe aortic stenosis: A randomized trial of a self-expanding prosthesis.
Zorn GL; Little SH; Tadros P; Deeb GM; Gleason TG; Heiser J; Kleiman NS; Oh JK; Popma JJ; Adams D; Huang J; Reardon MJ
J Thorac Cardiovasc Surg; 2016 Apr; 151(4):1014-22, 1023.e1-3. PubMed ID: 26614412
[TBL] [Abstract][Full Text] [Related]
4. Impact of Flow on Prosthesis-Patient Mismatch Following Transcatheter and Surgical Aortic Valve Replacement.
Abbas AE; Ternacle J; Pibarot P; Xu K; Alu M; Rogers E; Hahn RT; Leon M; Thourani VH
Circ Cardiovasc Imaging; 2021 Aug; 14(8):e012364. PubMed ID: 34387097
[TBL] [Abstract][Full Text] [Related]
5. Self-Expanding Transcatheter Aortic Valve Replacement Versus Surgical Valve Replacement in Patients at High Risk for Surgery: A Study of Echocardiographic Change and Risk Prediction.
Little SH; Oh JK; Gillam L; Sengupta PP; Orsinelli DA; Cavalcante JL; Chang JD; Adams DH; Zorn GL; Pollak AW; Abdelmoneim SS; Reardon MJ; Qiao H; Popma JJ
Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27313280
[TBL] [Abstract][Full Text] [Related]
6. Impact of Valve Size on Prosthesis-Patient Mismatch and Aortic Valve Gradient After Transcatheter versus Surgical Aortic Valve Replacement.
Aalaei-Andabili SH; Lee TC; Waheed N; Bavry AA; Petersen JW; Wayangankar S; Arnaoutakis GJ; David Anderson R; Beaver TM
Innovations (Phila); 2019 Jun; 14(3):243-250. PubMed ID: 31074313
[TBL] [Abstract][Full Text] [Related]
7. Valve Hemodynamics and Clinical Outcomes After Transcatheter Aortic Valve Replacement for a Small Aortic Annulus.
Kamioka N; Arita T; Hanyu M; Hayashi M; Watanabe S; Miura S; Isotani A; Arai Y; Kakumoto S; Ando K; Shirai S
Int Heart J; 2019 Jan; 60(1):86-92. PubMed ID: 30464118
[TBL] [Abstract][Full Text] [Related]
8. Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort--a analysis.
Pibarot P; Weissman NJ; Stewart WJ; Hahn RT; Lindman BR; McAndrew T; Kodali SK; Mack MJ; Thourani VH; Miller DC; Svensson LG; Herrmann HC; Smith CR; Rodés-Cabau J; Webb J; Lim S; Xu K; Hueter I; Douglas PS; Leon MB
J Am Coll Cardiol; 2014 Sep; 64(13):1323-34. PubMed ID: 25257633
[TBL] [Abstract][Full Text] [Related]
9. No clinical effect of prosthesis-patient mismatch after transcatheter versus surgical aortic valve replacement in intermediate- and low-risk patients with severe aortic valve stenosis at mid-term follow-up: an analysis from the NOTION trial.
Thyregod HG; Steinbrüchel DA; Ihlemann N; Ngo TA; Nissen H; Kjeldsen BJ; Chang Y; Hansen PB; Olsen PS; Søndergaard L
Eur J Cardiothorac Surg; 2016 Oct; 50(4):721-728. PubMed ID: 27005980
[TBL] [Abstract][Full Text] [Related]
10. Impact of small prosthesis size on transcatheter or surgical aortic valve replacement outcomes.
Salna M; Khalique OK; Chiuzan C; Kurlansky P; Borger MA; Hahn RT; Leon MB; Smith CR; Kodali SK; George I
Catheter Cardiovasc Interv; 2018 Mar; 91(4):765-773. PubMed ID: 28470996
[TBL] [Abstract][Full Text] [Related]
11. Prosthesis-Patient Mismatch After Aortic Valve Replacement in the PARTNER 2 Trial and Registry.
Ternacle J; Pibarot P; Herrmann HC; Kodali S; Leipsic J; Blanke P; Jaber W; Mack MJ; Clavel MA; Salaun E; Guzzetti E; Annabi MS; Bernier M; Beaudoin J; Khalique OK; Weissman NJ; Douglas P; Bax J; Dahou A; Xu K; Alu M; Rogers E; Leon M; Thourani VH; Abbas AE; Hahn RT
JACC Cardiovasc Interv; 2021 Jul; 14(13):1466-1477. PubMed ID: 34238557
[TBL] [Abstract][Full Text] [Related]
12. Predicting patient-prosthesis mismatch by aortic root evaluation before aortic valve replacement.
Maeda K; Kuratani T; Yoshioka D; Pak K; Shimamura K; Toda K; Sawa Y
J Thorac Cardiovasc Surg; 2019 Jul; 158(1):61-69.e4. PubMed ID: 30685162
[TBL] [Abstract][Full Text] [Related]
13. Longitudinal Hemodynamics of Transcatheter and Surgical Aortic Valves in the PARTNER Trial.
Douglas PS; Leon MB; Mack MJ; Svensson LG; Webb JG; Hahn RT; Pibarot P; Weissman NJ; Miller DC; Kapadia S; Herrmann HC; Kodali SK; Makkar RR; Thourani VH; Lerakis S; Lowry AM; Rajeswaran J; Finn MT; Alu MC; Smith CR; Blackstone EH;
JAMA Cardiol; 2017 Nov; 2(11):1197-1206. PubMed ID: 28973520
[TBL] [Abstract][Full Text] [Related]
14. Hemodynamic performance and outcome of percutaneous versus surgical stentless bioprostheses for aortic stenosis with anticipated patient-prosthesis mismatch.
Finkelstein A; Schwartz AL; Uretzky G; Banai S; Keren G; Kramer A; Topilsky Y
J Thorac Cardiovasc Surg; 2014 Jun; 147(6):1892-9. PubMed ID: 23993320
[TBL] [Abstract][Full Text] [Related]
15. Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement: The All-Comers Nordic Aortic Valve Intervention Randomized Clinical Trial.
Søndergaard L; Steinbrüchel DA; Ihlemann N; Nissen H; Kjeldsen BJ; Petursson P; Ngo AT; Olsen NT; Chang Y; Franzen OW; Engstrøm T; Clemmensen P; Olsen PS; Thyregod HG
Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27296202
[TBL] [Abstract][Full Text] [Related]
16. Valve Hemodynamics Following Transcatheter or Surgical Aortic Valve Replacement in Patients With Small Aortic Annulus.
Guimarães L; Voisine P; Mohammadi S; Kalavrouzioutis D; Dumont E; Doyle D; Paradis JM; Delarochellière R; Wintzer-Wehekind J; Junquera L; Del Val D; Muntané-Carol G; Freitas-Ferraz AB; Pibarot P; Dagenais F; Rodés-Cabau J
Am J Cardiol; 2020 Mar; 125(6):956-963. PubMed ID: 31948662
[TBL] [Abstract][Full Text] [Related]
17. Complications After Self-expanding Transcatheter or Surgical Aortic Valve Replacement.
Conte JV; Hermiller J; Resar JR; Deeb GM; Gleason TG; Adams DH; Popma JJ; Yakubov SJ; Watson D; Guo J; Zorn GL; Reardon MJ
Semin Thorac Cardiovasc Surg; 2017 Autumn; 29(3):321-330. PubMed ID: 29195573
[TBL] [Abstract][Full Text] [Related]
18. Transcatheter Aortic Valve Replacement Versus Surgery in Women at High Risk for Surgical Aortic Valve Replacement (from the CoreValve US High Risk Pivotal Trial).
Skelding KA; Yakubov SJ; Kleiman NS; Reardon MJ; Adams DH; Huang J; Forrest JK; Popma JJ
Am J Cardiol; 2016 Aug; 118(4):560-6. PubMed ID: 27381665
[TBL] [Abstract][Full Text] [Related]
19. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement.
Freeman M; Webb JG; Willson AB; Wheeler M; Blanke P; Moss RR; Thompson CR; Munt B; Norgaard BL; Yang TH; Min JK; Poulsen S; Hansson NC; Binder RK; Toggweiler S; Hague C; Wood DA; Pibarot P; Leipsic J
J Cardiovasc Comput Tomogr; 2013; 7(4):248-55. PubMed ID: 24148778
[TBL] [Abstract][Full Text] [Related]
20. Differences in left ventricular remodelling in patients with aortic stenosis treated with transcatheter aortic valve replacement with corevalve prostheses compared to surgery with porcine or bovine biological prostheses.
Ngo A; Hassager C; Thyregod HGH; Søndergaard L; Olsen PS; Steinbrüchel D; Hansen PB; Kjærgaard J; Winther-Jensen M; Ihlemann N
Eur Heart J Cardiovasc Imaging; 2018 Jan; 19(1):39-46. PubMed ID: 28158582
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]