147 related articles for article (PubMed ID: 29314632)
1. Comparison of five specific assays for determination of dabigatran plasma concentrations in patients enrolled in the START-Laboratory Register.
Cini M; Legnani C; Cosmi B; Testa S; Dellanoce C; Paoletti O; Marcucci R; Poli D; Paniccia R; Pengo V; Tripodi A; Palareti G;
Int J Lab Hematol; 2018 Apr; 40(2):229-236. PubMed ID: 29314632
[TBL] [Abstract][Full Text] [Related]
2. Estimation of dabigatran plasma concentrations in the perioperative setting. An ex vivo study using dedicated coagulation assays.
Douxfils J; Lessire S; Dincq AS; Hjemdahl P; Rönquist-Nii Y; Pohanka A; Gourdin M; Chatelain B; Dogné JM; Mullier F
Thromb Haemost; 2015 Apr; 113(4):862-9. PubMed ID: 25519251
[TBL] [Abstract][Full Text] [Related]
3. Measurement of dabigatran plasma concentrations by calibrated thrombin clotting time in comparison to LC-MS/MS in human volunteers on dialysis.
Schmohl M; Gansser D; Moschetti V; Stangier J
Thromb Res; 2015 Mar; 135(3):532-6. PubMed ID: 25600440
[TBL] [Abstract][Full Text] [Related]
4. Comparisons between diluted thrombin time, ecarin chromogenic assays, and UPLC-MS for plasma level dabigatran quantification: Results from DRIVING study.
de Fautereau-Vassel A; Mokhtarian A; Mangenot M; Krekounian O; Kousignian I; Delavenne X; Curis E; Gouin-Thibault I; Siguret V
Int J Lab Hematol; 2024 Feb; 46(1):120-127. PubMed ID: 37710085
[TBL] [Abstract][Full Text] [Related]
5. Determination of dabigatran in plasma, serum, and urine samples: comparison of six methods.
Du S; Weiss C; Christina G; Krämer S; Wehling M; Krämer R; Harenberg J
Clin Chem Lab Med; 2015 Jul; 53(8):1237-47. PubMed ID: 25720084
[TBL] [Abstract][Full Text] [Related]
6. Comparison of the ecarin chromogenic assay and diluted thrombin time for quantification of dabigatran concentrations.
Jaffer IH; Chan N; Roberts R; Fredenburgh JC; Eikelboom JW; Weitz JI
J Thromb Haemost; 2017 Dec; 15(12):2377-2387. PubMed ID: 28976630
[TBL] [Abstract][Full Text] [Related]
7. Using the HEMOCLOT direct thrombin inhibitor assay to determine plasma concentrations of dabigatran.
Stangier J; Feuring M
Blood Coagul Fibrinolysis; 2012 Mar; 23(2):138-43. PubMed ID: 22227958
[TBL] [Abstract][Full Text] [Related]
8. Diluted thrombin time reliably measures low to intermediate plasma dabigatran concentrations.
Božič-Mijovski M; Malmström RE; Malovrh P; Antovic JP; Vene N; Šinigoj P; Mavri A
Ann Clin Biochem; 2016 Jul; 53(Pt 4):446-51. PubMed ID: 26392631
[TBL] [Abstract][Full Text] [Related]
9. Measuring dabigatran concentrations using a chromogenic ecarin clotting time assay.
Gosselin RC; Dwyre DM; Dager WE
Ann Pharmacother; 2013 Dec; 47(12):1635-40. PubMed ID: 24259624
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of dabigatran, rivaroxaban and apixaban target-specific assays in a multicenter French study.
Gouin-Thibault I; Freyburger G; de Maistre E; Susen S; Delavenne X; Golmard JL; Gruel Y; Sié P;
Thromb Res; 2017 Oct; 158():126-133. PubMed ID: 28892657
[TBL] [Abstract][Full Text] [Related]
11. The effect of dabigatran on thrombin generation and coagulation assays in rabbit and human plasma.
Zhang C; Zhang P; Li H; Han L; Zhang L; Zhang L; Yang X
Thromb Res; 2018 May; 165():38-43. PubMed ID: 29558660
[TBL] [Abstract][Full Text] [Related]
12. Dabigatran assessment in patients with acute complications using routine coagulation assays.
Stang L; Nahirniak S; Butcher K; Szkotak AJ
Blood Coagul Fibrinolysis; 2014 Jul; 25(5):426-34. PubMed ID: 24637695
[TBL] [Abstract][Full Text] [Related]
13. Diagnostic Accuracy of a Novel Chromogenic Direct Thrombin Inhibitor Assay: Clinical Experiences for Dabigatran Monitoring.
Poli S; Härtig F; Spencer C; Ebner M; Birschmann I; Kuhn J; Faix S; Ziemann U; Häring HU; Lehmann R; Peter A; Hörber S
Thromb Haemost; 2017 Dec; 117(12):2369-2375. PubMed ID: 29212124
[TBL] [Abstract][Full Text] [Related]
14. Impact of dabigatran on a large panel of routine or specific coagulation assays. Laboratory recommendations for monitoring of dabigatran etexilate.
Douxfils J; Mullier F; Robert S; Chatelain C; Chatelain B; Dogné JM
Thromb Haemost; 2012 May; 107(5):985-97. PubMed ID: 22438031
[TBL] [Abstract][Full Text] [Related]
15. Measuring dabigatran with the dilute Russell viper venom confirm assay in an anticoagulation clinic population.
McGlasson DL; Fritsma GA
Blood Coagul Fibrinolysis; 2016 Jan; 27(1):53-7. PubMed ID: 26258670
[TBL] [Abstract][Full Text] [Related]
16. [Monitoring of Oral Thrombin Inhibitor].
Matsuno K; Usami T; Hatuse M; Shimizu C
Rinsho Byori; 2014 Oct; 62(10):958-64. PubMed ID: 27526541
[TBL] [Abstract][Full Text] [Related]
17. The effect of dabigatran on haemostasis tests: a comprehensive assessment using in vitro and ex vivo samples.
Bonar R; Favaloro EJ; Mohammed S; Pasalic L; Sioufi J; Marsden K
Pathology; 2015 Jun; 47(4):355-64. PubMed ID: 25938348
[TBL] [Abstract][Full Text] [Related]
18. Basic coagulation tests as surrogates of dabigatran levels in a pre-operative setting: Analysis of five activated partial thromboplastin time reagents and thrombin time.
Dubé C; Douketis JD; Moffat KA; Schulman S; Blais N
Thromb Res; 2018 Nov; 171():62-67. PubMed ID: 30261356
[TBL] [Abstract][Full Text] [Related]
19. Comparison of calibrated dilute thrombin time and aPTT tests with LC-MS/MS for the therapeutic monitoring of patients treated with dabigatran etexilate.
Douxfils J; Dogné JM; Mullier F; Chatelain B; Rönquist-Nii Y; Malmström RE; Hjemdahl P
Thromb Haemost; 2013 Sep; 110(3):543-9. PubMed ID: 23783171
[TBL] [Abstract][Full Text] [Related]
20. The anticoagulant effect of therapeutic levels of dabigatran in atrial fibrillation evaluated by thrombelastography (TEG
Solbeck S; Jensen AS; Maschmann C; Stensballe J; Ostrowski SR; Johansson PI
Scand J Clin Lab Invest; 2018; 78(1-2):25-30. PubMed ID: 29304563
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]