312 related articles for article (PubMed ID: 29316652)
21. A novel nonenzymatic amperometric hydrogen peroxide sensor based on CuO@Cu2O nanowires embedded into poly(vinyl alcohol).
Chirizzi D; Guascito MR; Filippo E; Tepore A
Talanta; 2016 Jan; 147():124-31. PubMed ID: 26592586
[TBL] [Abstract][Full Text] [Related]
22. A new method for fabricating a CuO/TiO2 nanotube arrays electrode and its application as a sensitive nonenzymatic glucose sensor.
Luo S; Su F; Liu C; Li J; Liu R; Xiao Y; Li Y; Liu X; Cai Q
Talanta; 2011 Oct; 86():157-63. PubMed ID: 22063525
[TBL] [Abstract][Full Text] [Related]
23. A Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV).
Dai Y; Molazemhosseini A; Liu CC
Biosensors (Basel); 2017 Feb; 7(1):. PubMed ID: 28218731
[TBL] [Abstract][Full Text] [Related]
24. Synthesis of novel CuO nanosheets and their non-enzymatic glucose sensing applications.
Ibupoto ZH; Khun K; Beni V; Liu X; Willander M
Sensors (Basel); 2013 Jun; 13(6):7926-38. PubMed ID: 23787727
[TBL] [Abstract][Full Text] [Related]
25. In Vitro Quantified Determination of β-Amyloid 42 Peptides, a Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using a Simple, Cost-Effective Thin Gold Film Biosensor.
Dai Y; Molazemhosseini A; Liu CC
Biosensors (Basel); 2017 Jul; 7(3):. PubMed ID: 28726727
[TBL] [Abstract][Full Text] [Related]
26. A highly sensitive nonenzymatic glucose sensor based on CuO nanoparticles-modified carbon nanotube electrode.
Jiang LC; Zhang WD
Biosens Bioelectron; 2010 Feb; 25(6):1402-7. PubMed ID: 19942424
[TBL] [Abstract][Full Text] [Related]
27. A highly sensitive non-enzymatic glucose sensor based on bimetallic Cu-Ag superstructures.
Li H; Guo CY; Xu CL
Biosens Bioelectron; 2015 Jan; 63():339-346. PubMed ID: 25113052
[TBL] [Abstract][Full Text] [Related]
28. A highly sensitive non-enzymatic glucose sensor based on a simple two-step electrodeposition of cupric oxide (CuO) nanoparticles onto multi-walled carbon nanotube arrays.
Yang J; Jiang LC; Zhang WD; Gunasekaran S
Talanta; 2010 Jun; 82(1):25-33. PubMed ID: 20685430
[TBL] [Abstract][Full Text] [Related]
29. A potentiometric non-enzymatic glucose sensor using a molecularly imprinted layer bonded on a conducting polymer.
Kim DM; Moon JM; Lee WC; Yoon JH; Choi CS; Shim YB
Biosens Bioelectron; 2017 May; 91():276-283. PubMed ID: 28024285
[TBL] [Abstract][Full Text] [Related]
30. Spherulitic copper-copper oxide nanostructure-based highly sensitive nonenzymatic glucose sensor.
Das G; Tran TQ; Yoon HH
Int J Nanomedicine; 2015; 10 Spec Iss(Spec Iss):165-78. PubMed ID: 26346651
[TBL] [Abstract][Full Text] [Related]
31. Archetypal sandwich-structured CuO for high performance non-enzymatic sensing of glucose.
Meher SK; Rao GR
Nanoscale; 2013 Mar; 5(5):2089-99. PubMed ID: 23381131
[TBL] [Abstract][Full Text] [Related]
32. Surface plasmon aided high sensitive non-enzymatic glucose sensor using Au/NiAu multilayered nanowire arrays.
Wang L; Zhu W; Lu W; Qin X; Xu X
Biosens Bioelectron; 2018 Jul; 111():41-46. PubMed ID: 29631162
[TBL] [Abstract][Full Text] [Related]
33. Highly Responsive and Ultrasensitive
Shen N; Xu H; Zhao W; Zhao Y; Zhang X
Sensors (Basel); 2019 Mar; 19(5):. PubMed ID: 30857279
[TBL] [Abstract][Full Text] [Related]
34. Application of functionalized multi-walled carbon nanotubes supporting cuprous oxide and silver oxide composite catalyst on copper substrate for simultaneous detection of vitamin B
Puangjan A; Chaiyasith S; Taweeporngitgul W; Keawtep J
Mater Sci Eng C Mater Biol Appl; 2017 Jul; 76():383-397. PubMed ID: 28482542
[TBL] [Abstract][Full Text] [Related]
35. Non-enzymatic glucose detection using as-prepared boron-doped diamond thin-film electrodes.
Zhao J; Wu L; Zhi J
Analyst; 2009 Apr; 134(4):794-9. PubMed ID: 19305932
[TBL] [Abstract][Full Text] [Related]
36. Nonenzymatic amperometric response of glucose on a nanoporous gold film electrode fabricated by a rapid and simple electrochemical method.
Xia Y; Huang W; Zheng J; Niu Z; Li Z
Biosens Bioelectron; 2011 Apr; 26(8):3555-61. PubMed ID: 21354778
[TBL] [Abstract][Full Text] [Related]
37. Amperometric glucose biosensor based on glucose oxidase-lectin biospecific interaction.
Zhang J; Wang C; Chen S; Yuan D; Zhong X
Enzyme Microb Technol; 2013 Mar; 52(3):134-40. PubMed ID: 23410923
[TBL] [Abstract][Full Text] [Related]
38. Different Electrochemical Sensor Designs Based on Diazonium Salts and Gold Nanoparticles for Pico Molar Detection of Metals.
Ait-Touchente Z; Falah S; Scavetta E; Chehimi MM; Touzani R; Tonelli D; Taleb A
Molecules; 2020 Aug; 25(17):. PubMed ID: 32867096
[TBL] [Abstract][Full Text] [Related]
39. Metal-Organic-Framework FeBDC-Derived Fe
Abrori SA; Septiani NLW; Nugraha ; Anshori I; Suyatman ; Suendo V; Yuliarto B
Sensors (Basel); 2020 Aug; 20(17):. PubMed ID: 32872490
[TBL] [Abstract][Full Text] [Related]
40. Pulse electrodeposited nickel-indium tin oxide nanocomposite as an electrocatalyst for non-enzymatic glucose sensing.
Sivasakthi P; Ramesh Bapu GN; Chandrasekaran M
Mater Sci Eng C Mater Biol Appl; 2016 Jan; 58():782-9. PubMed ID: 26478372
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]