BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 29317750)

  • 21. Target concentrations of remifentanil with propofol to blunt coughing during intubation, cuff inflation, and tracheal suctioning.
    Leone M; Rousseau S; Avidan M; Delmas A; Viviand X; Guyot L; Martin C
    Br J Anaesth; 2004 Nov; 93(5):660-3. PubMed ID: 15321933
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A schlieren optical study of the human cough with and without wearing masks for aerosol infection control.
    Tang JW; Liebner TJ; Craven BA; Settles GS
    J R Soc Interface; 2009 Dec; 6 Suppl 6(Suppl 6):S727-36. PubMed ID: 19815575
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems.
    Qian H; Li Y; Nielsen PV; Hyldgaard CE; Wong TW; Chwang AT
    Indoor Air; 2006 Apr; 16(2):111-28. PubMed ID: 16507039
    [TBL] [Abstract][Full Text] [Related]  

  • 24. An audible indication of exhalation increases delivered tidal volume during bag valve mask ventilation of a patient simulator.
    Lampotang S; Lizdas DE; Gravenstein N; Robicsek S
    Anesth Analg; 2006 Jan; 102(1):168-71. PubMed ID: 16368824
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Expiratory aerosol particle escape from surgical masks due to imperfect sealing.
    Cappa CD; Asadi S; Barreda S; Wexler AS; Bouvier NM; Ristenpart WD
    Sci Rep; 2021 Jun; 11(1):12110. PubMed ID: 34103573
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Influence of face mask design on bag-valve-mask ventilation performance: a randomized simulation study.
    Na JU; Han SK; Choi PC; Cho JH; Shin DH
    Acta Anaesthesiol Scand; 2013 Oct; 57(9):1186-92. PubMed ID: 23962096
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Randomised comparison of two neonatal resuscitation bags in manikin ventilation.
    Thallinger M; Ersdal HL; Ombay C; Eilevstjønn J; Størdal K
    Arch Dis Child Fetal Neonatal Ed; 2016 Jul; 101(4):F299-303. PubMed ID: 26437670
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Minimizing Aerosol Leakage from Facemasks in the COVID-19 Pandemic.
    Frankfort MGH; Lauwers I; Pruijn EMC; Dijkstra SF; Boormans LHG; Schouten NA; van Donkelaar CC; Janssens HM;
    J Aerosol Med Pulm Drug Deliv; 2023 Jun; 36(3):101-111. PubMed ID: 37172274
    [No Abstract]   [Full Text] [Related]  

  • 29. Position of exhalation port and mask design affect CO2 rebreathing during noninvasive positive pressure ventilation.
    Schettino GP; Chatmongkolchart S; Hess DR; Kacmarek RM
    Crit Care Med; 2003 Aug; 31(8):2178-82. PubMed ID: 12973177
    [TBL] [Abstract][Full Text] [Related]  

  • 30. VACuum INtubation (VACcIN) box restricts the exhaled air dispersion generated by simulated cough: description and simulation-based tests of an innovative aerosolization protective prototype.
    Issa R; Urbanowicz R; Richebé P; Blain J; Ferreira Benevides A; Tanoubi I
    J Clin Monit Comput; 2022 Oct; 36(5):1289-1295. PubMed ID: 34562184
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Exhalation of respiratory viruses by breathing, coughing, and talking.
    Stelzer-Braid S; Oliver BG; Blazey AJ; Argent E; Newsome TP; Rawlinson WD; Tovey ER
    J Med Virol; 2009 Sep; 81(9):1674-9. PubMed ID: 19626609
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Some questions on dispersion of human exhaled droplets in ventilation room: answers from numerical investigation.
    Chen C; Zhao B
    Indoor Air; 2010 Apr; 20(2):95-111. PubMed ID: 20002792
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Aerosol generation during general anesthesia is comparable to coughing: An observational clinical study.
    Oksanen LM; Sanmark E; Sofieva S; Rantanen N; Lahelma M; Anttila VJ; Lehtonen L; Atanasova N; Pesonen E; Geneid A; Hyvärinen AP
    Acta Anaesthesiol Scand; 2022 Apr; 66(4):463-472. PubMed ID: 34951703
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Particulate face masks for protection against airborne pathogens - one size does not fit all: an observational study.
    Winter S; Thomas JH; Stephens DP; Davis JS
    Crit Care Resusc; 2010 Mar; 12(1):24-7. PubMed ID: 20196710
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Positive expiratory pressure via mask does not improve ventilation inhomogeneity more than huffing and coughing in individuals with stable chronic obstructive pulmonary disease and chronic sputum expectoration.
    Osadnik C; Stuart-Andrews C; Ellis S; Thompson B; McDonald CF; Holland AE
    Respiration; 2014; 87(1):38-44. PubMed ID: 23752553
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of different airway management strategies to ventilate apneic, nonpreoxygenated patients.
    Dörges V; Wenzel V; Knacke P; Gerlach K
    Crit Care Med; 2003 Mar; 31(3):800-4. PubMed ID: 12626987
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Overuse/Abuse of the Definition of "Aerosol-Generating Procedures" to Limit Mask Use.
    Baerlocher MO; Baerlocher FJ
    J Vasc Interv Radiol; 2020 Jul; 31(7):1189-1191. PubMed ID: 32457009
    [No Abstract]   [Full Text] [Related]  

  • 38. [Exhaled droplets and Covid-19].
    Bake B; Ljungström E; Almstrand AC; Olin AC
    Lakartidningen; 2021 Jun; 118():. PubMed ID: 34132381
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Modification of an aerosol mask to provide high concentrations of oxygen in the inspired air. Comparison to a nonrebreathing mask.
    Chechani V; Scott G; Burnham B; Knight L
    Chest; 1991 Dec; 100(6):1582-5. PubMed ID: 1959399
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of face masks in the bag-mask ventilation of a manikin.
    Redfern D; Rassam S; Stacey MR; Mecklenburgh JS
    Eur J Anaesthesiol; 2006 Feb; 23(2):169-72. PubMed ID: 16426473
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.