These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

221 related articles for article (PubMed ID: 2932625)

  • 21. Leakage flow at mechanical heart valve prostheses: improved washout or increased blood damage?
    Steegers A; Paul R; Reul H; Rau G
    J Heart Valve Dis; 1999 May; 8(3):312-23. PubMed ID: 10399668
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Shear stress investigation across mechanical heart valve.
    Zhang P; Yeo JH; Qian P; Hwang NH
    ASAIO J; 2007; 53(5):530-6. PubMed ID: 17885324
    [TBL] [Abstract][Full Text] [Related]  

  • 23. High-resolution assessment of velocity fields and shear stresses distal to prosthetic heart valves using high-field magnetic resonance imaging.
    Ringgaard S; Botnar RM; Djurhuus C; Stodkilde-Jorgensen H; Hasenkam JM; Boesiger P; Pedersen EM
    J Heart Valve Dis; 1999 Jan; 8(1):96-103. PubMed ID: 10096490
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Prosthesis-induced hemolysis: mechanisms and quantification of shear stress.
    Ellis JT; Wick TM; Yoganathan AP
    J Heart Valve Dis; 1998 Jul; 7(4):376-86. PubMed ID: 9697058
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Estimation of turbulent shear stresses in pulsatile flow immediately downstream of two artificial aortic valves in vitro.
    Nygaard H; Giersiepen M; Hasenkam JM; Westphal D; Paulsen PK; Reul H
    J Biomech; 1990; 23(12):1231-8. PubMed ID: 2292602
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Hydrogen bubble visualization of the flow past aortic prosthetic valves.
    Lichtenstein O; Martínez-Val R; Méndez J; Castillo-Olivares JL
    Life Support Syst; 1986; 4(2):141-9. PubMed ID: 2943946
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Estimating mechanical blood trauma in a centrifugal blood pump: laser Doppler anemometer measurements of the mean velocity field.
    Pinotti M; Paone N
    Artif Organs; 1996 Jun; 20(6):546-52. PubMed ID: 8817953
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A new flow model for Doppler ultrasound study of prosthetic heart valves.
    Durand LG; Garcia D; Sakr F; Sava H; Cimon R; Pibarot P; Fenster A; Dumesnil JG
    J Heart Valve Dis; 1999 Jan; 8(1):85-95. PubMed ID: 10096489
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Pulsatile flow velocity and shear stress measurements on the St. Jude bileaflet valve prosthesis.
    Woo YR; Yoganathan AP
    Scand J Thorac Cardiovasc Surg; 1986; 20(1):15-28. PubMed ID: 2939558
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Turbulent stresses in the region of aortic and pulmonary valves.
    Stein PD; Walburn FJ; Sabbah HN
    J Biomech Eng; 1982 Aug; 104(3):238-44. PubMed ID: 7120950
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Velocity and turbulence measurements past mitral valve prostheses in a model left ventricle.
    Schoephoerster RT; Chandran KB
    J Biomech; 1991; 24(7):549-62. PubMed ID: 1880139
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of laser Doppler anemometry and hot-film anemometry for visualizing velocity fields downstream of different heart valves in a pulsatile mock circulation.
    Hasenkam JM; Giersiepen M; Schindehütte H; Reul H; Gormsen J; Paulsen PK
    Life Support Syst; 1985; 3 Suppl 1():162-6. PubMed ID: 2959821
    [No Abstract]   [Full Text] [Related]  

  • 33. Holographic velocimetry: an alternative approach for flow characterization of prosthetic heart valves.
    Schuster PR; Wagner JW
    Med Prog Technol; 1988-1989; 14(3-4):177-91. PubMed ID: 2978591
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Influence of cardiac flow rate on turbulent shear stress from a prosthetic heart valve.
    Schwarz AC; Tiederman WG; Phillips WM
    J Biomech Eng; 1988 May; 110(2):123-8. PubMed ID: 2967905
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Turbulent stress measurements downstream of three bileaflet heart valve designs in pigs.
    Nyboe C; Funder JA; Smerup MH; Nygaard H; Hasenkam JM
    Eur J Cardiothorac Surg; 2006 Jun; 29(6):1008-13. PubMed ID: 16675253
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Can regurgitant flow damage the left atrial endothelium in patients with prosthetic mechanical heart valves?
    Milo S; Zarandi M; Gutfinger C; Gharib M
    J Heart Valve Dis; 2005 May; 14(3):344-52. PubMed ID: 15974529
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Experimental flow studies in an elastic Y-model.
    Mijovic B; Liepsch D
    Technol Health Care; 2003; 11(2):115-41. PubMed ID: 12697953
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Velocity and shear stress distribution downstream of mechanical heart valves in pulsatile flow.
    Giersiepen M; Krause U; Knott E; Reul H; Rau G
    Int J Artif Organs; 1989 Apr; 12(4):261-9. PubMed ID: 2722280
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Flow in prosthetic heart valves: state-of-the-art and future directions.
    Yoganathan AP; Chandran KB; Sotiropoulos F
    Ann Biomed Eng; 2005 Dec; 33(12):1689-94. PubMed ID: 16389514
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Assessment of prosthetic valve hemodynamics by Doppler: lessons from in vitro studies of the St. Jude valve.
    Khan SS
    J Heart Valve Dis; 1993 Mar; 2(2):183-93. PubMed ID: 8261156
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.