These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 29327562)

  • 1. Development of a porcine beating-heart model of self-myocardial retroperfusion: evaluation of hemodynamic and cardiac responses to ischemia and clinical applications.
    Grandmougin D; Casse JM; Chalon A; Luo Y; Falanga A; Marie V; Groubatch-Joineau F; Mourer B; Grandmougin M; Grandmougin D; Gauchotte G; Maureira JP; Tran N
    J Cardiovasc Surg (Torino); 2018 Jun; 59(3):438-452. PubMed ID: 29327562
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of the self-myocardial retroperfusion with aortic-coronary sinus shunt on cardiac output and ischemic events in high-risk patients undergoing OPCAB surgery.
    Grandmougin D; Vanhuyse F; Fiore A; Delolme MC; Liu Y; Laurent N; Bertram M; Folliguet T; Tran N; Maureira JP
    J Cardiovasc Surg (Torino); 2015 Dec; 56(6):929-37. PubMed ID: 24647320
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Myocardial preservation in acute coronary artery occlusion with coronary sinus retroperfusion and carnitine.
    Katircioglu SF; Işcan HZ; Ulus T; Saritaş Z
    J Cardiovasc Surg (Torino); 2000 Feb; 41(1):45-50. PubMed ID: 10836220
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Modification of myocardial ischemia in normal and hypertrophied hearts utilizing diastolic retroperfusion of the coronary veins.
    Gundry SR
    J Thorac Cardiovasc Surg; 1982 May; 83(5):659-69. PubMed ID: 6210808
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Alteration of left ventriculo-arterial coupling and mechanical efficiency during acute myocardial ischemia.
    Kolh P; Lambermont B; Ghuysen A; D'Orio V; Gerard P; Morimont P; Tchana-Sato V; Piérard L; Dogné JM; Limet R
    Int Angiol; 2003 Jun; 22(2):148-58. PubMed ID: 12865880
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simplified retroperfusion system preserves the myocardial function during acute coronary artery occlusion.
    Katircioğlu SF; Yücel D; Saritas Z; Yamak B; Elsheikh AE; Köse K
    Thorac Cardiovasc Surg; 1998 Feb; 46(1):1-6. PubMed ID: 9554040
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intraluminal coronary shunting preserves regional myocardial perfusion and function.
    Sepic J; Wee JO; Soltesz EG; Laurence RG; Aklog L
    Heart Surg Forum; 2003; 6(6):E120-5. PubMed ID: 14721996
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Coronary venous synchronized retroperfusion during percutaneous transluminal angioplasty of left anterior descending coronary artery.
    Berland J; Farcot JC; Barrier A; Dellac A; Gamra H; Letac B
    Circulation; 1990 Mar; 81(3 Suppl):IV35-42. PubMed ID: 2306848
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reduction of the infarcted area with the use of simplified coronary sinus retroperfusion during experimental coronary artery occlusion.
    Katircioglu SF; Gökçe P; Ulus AT; Tütün U; Apaydin N; Koç B
    Int J Cardiol; 2000 Apr; 73(2):115-21. PubMed ID: 10817848
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Synchronized coronary venous retroperfusion: prompt improvement of left ventricular function in experimental myocardial ischemia.
    Yamazaki S; Drury JK; Meerbaum S; Corday E
    J Am Coll Cardiol; 1985 Mar; 5(3):655-63. PubMed ID: 3973263
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reduction of systolic and diastolic dysfunction by retrograde coronary sinus perfusion during off-pump coronary surgery.
    Castellá M; Buckberg GD
    J Thorac Cardiovasc Surg; 2004 Apr; 127(4):1018-25. PubMed ID: 15052198
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The bottleneck stent model for chronic myocardial ischemia and heart failure in pigs.
    Rissanen TT; Nurro J; Halonen PJ; Tarkia M; Saraste A; Rannankari M; Honkonen K; Pietilä M; Leppänen O; Kuivanen A; Knuuti J; Ylä-Herttuala S
    Am J Physiol Heart Circ Physiol; 2013 Nov; 305(9):H1297-308. PubMed ID: 23997096
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Experimental evidence of regional myocardial ischemia during beating heart coronary bypass: prevention with temporary intraluminal shunts.
    Gandra SM; Rivetti LA
    Heart Surg Forum; 2002; 6(1):10-8. PubMed ID: 12611726
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Proximal coronary hemodynamic changes evaluated by intracardiac echocardiography during myocardial ischemia and reperfusion in a canine model.
    Han B; Wei M
    Echocardiography; 2008 Mar; 25(3):312-20. PubMed ID: 18307445
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Coronary sinus retroperfusion during acute experimental coronary artery occlusion.
    Uzunonat G; Emir M; Yamak B; Ulus AT; Ulaş M; Uncu H; Saritaş Z; Katircioğlu SF; Taşdemir O
    J Cardiovasc Surg (Torino); 1999 Apr; 40(2):197-201. PubMed ID: 10350102
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Aortic-coronary sinus shunt retroperfusion protects against acute myocardial ischemia in pigs during off-pump beating heart surgery].
    Guo HM; Zhang JF; Wu RB; Zheng SY; Zhuang J
    Di Yi Jun Yi Da Xue Xue Bao; 2005 Apr; 25(4):457-61. PubMed ID: 15837656
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection of ischemia and new insight into left ventricular physiology by strain Doppler and tissue velocity imaging: assessment during coronary bypass operation of the beating heart.
    Skulstad H; Andersen K; Edvardsen T; Rein KA; Tønnessen TI; Hol PK; Fosse E; Ihlen H
    J Am Soc Echocardiogr; 2004 Dec; 17(12):1225-33. PubMed ID: 15562259
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hemodynamic impact of transseptal access to the ascending aorta in a porcine model.
    Wipper S; Lohrenz C; Peymann K; Russ D; Kersten JF; Carpenter SW; Larena-Avellaneda A; Detter C; Debus S; Kölbel T
    J Endovasc Ther; 2012 Oct; 19(5):679-88. PubMed ID: 23046337
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Detecting myocardial ischaemia using miniature ultrasonic transducers--a feasibility study in a porcine model.
    Espinoza A; Halvorsen PS; Hoff L; Skulstad H; Fosse E; Ihlen H; Edvardsen T
    Eur J Cardiothorac Surg; 2010 Jan; 37(1):119-26. PubMed ID: 19581103
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Contractile reserve and left ventricular function in regional myocardial ischemia in the dog.
    Yoran C; Sonnenblick EH; Kirk ES
    Circulation; 1982 Jul; 66(1):121-8. PubMed ID: 7083498
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.