These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
708 related articles for article (PubMed ID: 29328943)
1. Interval breast cancers in the 'screening with tomosynthesis or standard mammography' (STORM) population-based trial. Houssami N; Bernardi D; Caumo F; Brunelli S; Fantò C; Valentini M; Romanucci G; Gentilini MA; Zorzi M; Macaskill P Breast; 2018 Apr; 38():150-153. PubMed ID: 29328943 [TBL] [Abstract][Full Text] [Related]
2. Breast screening using 2D-mammography or integrating digital breast tomosynthesis (3D-mammography) for single-reading or double-reading--evidence to guide future screening strategies. Houssami N; Macaskill P; Bernardi D; Caumo F; Pellegrini M; Brunelli S; Tuttobene P; Bricolo P; Fantò C; Valentini M; Ciatto S Eur J Cancer; 2014 Jul; 50(10):1799-1807. PubMed ID: 24746887 [TBL] [Abstract][Full Text] [Related]
3. Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study. Ciatto S; Houssami N; Bernardi D; Caumo F; Pellegrini M; Brunelli S; Tuttobene P; Bricolo P; Fantò C; Valentini M; Montemezzi S; Macaskill P Lancet Oncol; 2013 Jun; 14(7):583-9. PubMed ID: 23623721 [TBL] [Abstract][Full Text] [Related]
4. Breast cancer detection using single-reading of breast tomosynthesis (3D-mammography) compared to double-reading of 2D-mammography: Evidence from a population-based trial. Houssami N; Bernardi D; Pellegrini M; Valentini M; Fantò C; Ostillio L; Tuttobene P; Luparia A; Macaskill P Cancer Epidemiol; 2017 Apr; 47():94-99. PubMed ID: 28192742 [TBL] [Abstract][Full Text] [Related]
5. Breast cancer screening with tomosynthesis (3D mammography) with acquired or synthetic 2D mammography compared with 2D mammography alone (STORM-2): a population-based prospective study. Bernardi D; Macaskill P; Pellegrini M; Valentini M; Fantò C; Ostillio L; Tuttobene P; Luparia A; Houssami N Lancet Oncol; 2016 Aug; 17(8):1105-1113. PubMed ID: 27345635 [TBL] [Abstract][Full Text] [Related]
6. Effect of integrating 3D-mammography (digital breast tomosynthesis) with 2D-mammography on radiologists' true-positive and false-positive detection in a population breast screening trial. Bernardi D; Caumo F; Macaskill P; Ciatto S; Pellegrini M; Brunelli S; Tuttobene P; Bricolo P; Fantò C; Valentini M; Montemezzi S; Houssami N Eur J Cancer; 2014 May; 50(7):1232-8. PubMed ID: 24582915 [TBL] [Abstract][Full Text] [Related]
7. Incremental effect from integrating 3D-mammography (tomosynthesis) with 2D-mammography: Increased breast cancer detection evident for screening centres in a population-based trial. Caumo F; Bernardi D; Ciatto S; Macaskill P; Pellegrini M; Brunelli S; Tuttobene P; Bricolo P; Fantò C; Valentini M; Montemezzi S; Houssami N Breast; 2014 Feb; 23(1):76-80. PubMed ID: 24316152 [TBL] [Abstract][Full Text] [Related]
8. Effect of integrating digital breast tomosynthesis (3D-mammography) with acquired or synthetic 2D-mammography on radiologists' true-positive and false-positive detection in a population screening trial: A descriptive study. Bernardi D; Li T; Pellegrini M; Macaskill P; Valentini M; Fantò C; Ostillio L; Houssami N Eur J Radiol; 2018 Sep; 106():26-31. PubMed ID: 30150047 [TBL] [Abstract][Full Text] [Related]
9. Effect of implementing digital breast tomosynthesis (DBT) instead of mammography on population screening outcomes including interval cancer rates: Results of the Trento DBT pilot evaluation. Bernardi D; Gentilini MA; De Nisi M; Pellegrini M; Fantò C; Valentini M; Sabatino V; Luparia A; Houssami N Breast; 2020 Apr; 50():135-140. PubMed ID: 31607526 [TBL] [Abstract][Full Text] [Related]
10. Breast cancers detected in only one of two arms of a tomosynthesis (3D-mammography) population screening trial (STORM-2). Bernardi D; Houssami N Breast; 2017 Apr; 32():98-101. PubMed ID: 28107735 [TBL] [Abstract][Full Text] [Related]
11. One-view breast tomosynthesis versus two-view mammography in the Malmö Breast Tomosynthesis Screening Trial (MBTST): a prospective, population-based, diagnostic accuracy study. Zackrisson S; Lång K; Rosso A; Johnson K; Dustler M; Förnvik D; Förnvik H; Sartor H; Timberg P; Tingberg A; Andersson I Lancet Oncol; 2018 Nov; 19(11):1493-1503. PubMed ID: 30322817 [TBL] [Abstract][Full Text] [Related]
12. Pilot trial of digital breast tomosynthesis (3D mammography) for population-based screening in BreastScreen Victoria. Houssami N; Lockie D; Clemson M; Pridmore V; Taylor D; Marr G; Evans J; Macaskill P Med J Aust; 2019 Oct; 211(8):357-362. PubMed ID: 31448816 [TBL] [Abstract][Full Text] [Related]
13. Digital breast tomosynthesis (3D-mammography) screening: A pictorial review of screen-detected cancers and false recalls attributed to tomosynthesis in prospective screening trials. Houssami N; Lång K; Bernardi D; Tagliafico A; Zackrisson S; Skaane P Breast; 2016 Apr; 26():119-34. PubMed ID: 27017251 [TBL] [Abstract][Full Text] [Related]
14. Radiologists' interpretive efficiency and variability in true- and false-positive detection when screen-reading with tomosynthesis (3D-mammography) relative to standard mammography in population screening. Svahn TM; Macaskill P; Houssami N Breast; 2015 Dec; 24(6):687-93. PubMed ID: 26433751 [TBL] [Abstract][Full Text] [Related]
15. Digital Breast Tomosynthesis with Synthesized Two-Dimensional Images versus Full-Field Digital Mammography for Population Screening: Outcomes from the Verona Screening Program. Caumo F; Zorzi M; Brunelli S; Romanucci G; Rella R; Cugola L; Bricolo P; Fedato C; Montemezzi S; Houssami N Radiology; 2018 Apr; 287(1):37-46. PubMed ID: 29237146 [TBL] [Abstract][Full Text] [Related]
16. Digital Mammography versus Digital Mammography Plus Tomosynthesis for Breast Cancer Screening: The Reggio Emilia Tomosynthesis Randomized Trial. Pattacini P; Nitrosi A; Giorgi Rossi P; Iotti V; Ginocchi V; Ravaioli S; Vacondio R; Braglia L; Cavuto S; Campari C; Radiology; 2018 Aug; 288(2):375-385. PubMed ID: 29869961 [TBL] [Abstract][Full Text] [Related]
17. Two-view digital breast tomosynthesis versus digital mammography in a population-based breast cancer screening programme (To-Be): a randomised, controlled trial. Hofvind S; Holen ÅS; Aase HS; Houssami N; Sebuødegård S; Moger TA; Haldorsen IS; Akslen LA Lancet Oncol; 2019 Jun; 20(6):795-805. PubMed ID: 31078459 [TBL] [Abstract][Full Text] [Related]
18. The TOMMY trial: a comparison of TOMosynthesis with digital MammographY in the UK NHS Breast Screening Programme--a multicentre retrospective reading study comparing the diagnostic performance of digital breast tomosynthesis and digital mammography with digital mammography alone. Gilbert FJ; Tucker L; Gillan MG; Willsher P; Cooke J; Duncan KA; Michell MJ; Dobson HM; Lim YY; Purushothaman H; Strudley C; Astley SM; Morrish O; Young KC; Duffy SW Health Technol Assess; 2015 Jan; 19(4):i-xxv, 1-136. PubMed ID: 25599513 [TBL] [Abstract][Full Text] [Related]
19. Performance of breast cancer screening using digital breast tomosynthesis: results from the prospective population-based Oslo Tomosynthesis Screening Trial. Skaane P; Sebuødegård S; Bandos AI; Gur D; Østerås BH; Gullien R; Hofvind S Breast Cancer Res Treat; 2018 Jun; 169(3):489-496. PubMed ID: 29429017 [TBL] [Abstract][Full Text] [Related]
20. Clinical performance metrics of 3D digital breast tomosynthesis compared with 2D digital mammography for breast cancer screening in community practice. Greenberg JS; Javitt MC; Katzen J; Michael S; Holland AE AJR Am J Roentgenol; 2014 Sep; 203(3):687-93. PubMed ID: 24918774 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]