BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 2932991)

  • 1. A comparison of external velour and double velour Dacron grafts in the canine thoracic aorta.
    Zammit M; Wu HD; Sauvage LR
    Am Surg; 1985 Nov; 51(11):637-40. PubMed ID: 2932991
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Healing of an external velour warp-knit Dacron vascular prosthesis].
    Usui Y; Sauvage LR; Uchida H; Teramoto S
    Nihon Geka Gakkai Zasshi; 1988 Oct; 89(10):1716-21. PubMed ID: 2974119
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of compliance alteration on healing of a porous dacron prosthesis in the thoracic aorta of the dog.
    Cengiz M; Sauvage LR; Berger K; Robel SB; Robel V; Wu H; Walker M; Appleyard RF; Wood SJ
    Surg Gynecol Obstet; 1984 Feb; 158(2):145-51. PubMed ID: 6229893
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro and in vivo evaluations of dacron velour and knit prostheses.
    Sawyer PN; Stanczewski B; Hoskin GP; Sophie Z; Stillman RM; Turner RJ; Hoffman HL
    J Biomed Mater Res; 1979 Nov; 13(6):937-56. PubMed ID: 159906
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The influence of inner wall filamentousness on the performance of small- and large-caliber arterial grafts.
    Wu HD; Zammit M; Sauvage LR; Streicher MD
    J Vasc Surg; 1985 Mar; 2(2):255-62. PubMed ID: 3974011
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of healing on compliance of porous Dacron grafts.
    Usui Y; Goff SG; Sauvage LR; Wu HD; Robel SB; Walker M
    Ann Vasc Surg; 1988 Apr; 2(2):120-6. PubMed ID: 2973803
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new woven double velour vascular prosthesis.
    Scott SM; Hoffman H; Gaddy LR; Sethi GK; Bridman AH
    J Cardiovasc Surg (Torino); 1985; 26(2):175-81. PubMed ID: 3156863
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of polytetrafluoroethylene (PTFE) and dacron as long, small-diameter arterial grafts in dogs.
    Randall RD; Walley BD; Meredith JH
    Am Surg; 1982 Dec; 48(12):622-7. PubMed ID: 6218768
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Endothelial cell seeding of small-diameter vascular grafts.
    Belden TA; Schmidt SP; Falkow LJ; Sharp WV
    Trans Am Soc Artif Intern Organs; 1982; 28():173-7. PubMed ID: 6219487
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence on healing in the canine thoracic aorta of three substances used to close the interstices of macroporous Dacron grafts.
    Zammit M; Wu HD; Mathisen SR; Sauvage LR
    Am Surg; 1986 Dec; 52(12):667-9. PubMed ID: 2947528
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A collagen coated vascular prosthesis.
    Scott SM; Gaddy LR; Sahmel R; Hoffman H
    J Cardiovasc Surg (Torino); 1987; 28(5):498-504. PubMed ID: 2958479
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Regeneration of endothelium in knitted and velour dacron vascular grafts in dogs.
    Hertzer NR
    J Cardiovasc Surg (Torino); 1981; 22(3):223-30. PubMed ID: 6454692
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Experimental and clinical experiences with double-velour woven Dacron prostheses.
    Haverich A; Maatz W; Stegmann T; Oelert H; Borst HG
    Thorac Cardiovasc Surg; 1986 Feb; 34(1):52-3. PubMed ID: 2421450
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Comparison of healing characteristics of DALLON-standard and DALLON-double velour vascular prostheses].
    Zimnoch L; Głowiński S; Andrzejewska A; Raczyński K; Kondracki S; Głowiński J
    Polim Med; 1992; 22(4):43-62. PubMed ID: 1305966
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dacron arterial grafts: the influence of porosity, velour, and maturity on thrombogenicity.
    Goldman M; McCollum CN; Hawker RJ; Drolc Z; Slaney G
    Surgery; 1982 Dec; 92(6):947-52. PubMed ID: 6216621
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence of denier and porosity on performance of a warp-knit Dacron arterial prosthesis.
    Mathisen SR; Wu HD; Sauvage LR; Robel SB; Wechezak AR; Walker M
    Ann Surg; 1986 Apr; 203(4):382-9. PubMed ID: 2421654
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An experimental study of eight current arterial prostheses.
    Mathisen SR; Wu HD; Sauvage LR; Usui Y; Walker MW
    J Vasc Surg; 1986 Jul; 4(1):33-41. PubMed ID: 2941595
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Late-stage, nonanastomotic rupture of double-velour Dacron graft after descending aortic replacement.
    Kawamura M; Ogino H; Matsuda H; Minatoya K; Sasaki H; Kitamura S
    J Thorac Cardiovasc Surg; 2006 Oct; 132(4):961-2. PubMed ID: 17000311
    [No Abstract]   [Full Text] [Related]  

  • 19. The effect of preclotting on surface thrombogenicity and thromboembolic complications of Dacron grafts in the canine thoracic aorta.
    Gloviczki P; Hollier LH; Hoffman EA; Plate G; Trastek VF; Kaye MP
    J Thorac Cardiovasc Surg; 1984 Aug; 88(2):253-8. PubMed ID: 6235404
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Polyester prostheses as substitutes in the thoracic aorta of dogs. I. Evaluation of commercial prostheses.
    Guidoin R; Gosselin C; Martin L; Marois M; Laroche F; King M; Gunasekera K; Domurado D; Sigot-Luizard MF; Blais P
    J Biomed Mater Res; 1983 Nov; 17(6):1049-77. PubMed ID: 6228554
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]