These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

230 related articles for article (PubMed ID: 29332200)

  • 1. Simultaneous multi-slice accelerated turbo spin echo of the knee in pediatric patients.
    Benali S; Johnston PR; Gholipour A; Dugan ME; Heberlein K; Bhat H; Bixby SD
    Skeletal Radiol; 2018 Jun; 47(6):821-831. PubMed ID: 29332200
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simultaneous Multislice Accelerated Turbo Spin Echo Magnetic Resonance Imaging: Comparison and Combination With In-Plane Parallel Imaging Acceleration for High-Resolution Magnetic Resonance Imaging of the Knee.
    Fritz J; Fritz B; Zhang J; Thawait GK; Joshi DH; Pan L; Wang D
    Invest Radiol; 2017 Sep; 52(9):529-537. PubMed ID: 28430716
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Six-Fold Acceleration of High-Spatial Resolution 3D SPACE MRI of the Knee Through Incoherent k-Space Undersampling and Iterative Reconstruction-First Experience.
    Fritz J; Raithel E; Thawait GK; Gilson W; Papp DF
    Invest Radiol; 2016 Jun; 51(6):400-9. PubMed ID: 26685106
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Three-Dimensional CAIPIRINHA SPACE TSE for 5-Minute High-Resolution MRI of the Knee.
    Fritz J; Fritz B; Thawait GG; Meyer H; Gilson WD; Raithel E
    Invest Radiol; 2016 Oct; 51(10):609-17. PubMed ID: 27187045
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Compressed Sensing SEMAC: 8-fold Accelerated High Resolution Metal Artifact Reduction MRI of Cobalt-Chromium Knee Arthroplasty Implants.
    Fritz J; Ahlawat S; Demehri S; Thawait GK; Raithel E; Gilson WD; Nittka M
    Invest Radiol; 2016 Oct; 51(10):666-76. PubMed ID: 27518214
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Is simultaneous multisection turbo spin echo ready for clinical MRI? A feasibility study on fast imaging of knee lesions.
    Li X; Peng Z; Sun Y; Cui J
    Clin Radiol; 2020 Mar; 75(3):238.e21-238.e30. PubMed ID: 31767143
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simultaneous Multislice Accelerated TSE for Improved Spatiotemporal Resolution and Diagnostic Accuracy in Magnetic Resonance Neurography: A Feasibility Study.
    Preisner F; Hayes JC; Charlet T; Carinci F; Hielscher T; Schwarz D; Vollherbst DF; Breckwoldt MO; Jesser J; Heiland S; Bendszus M; Hilgenfeld T
    Invest Radiol; 2023 May; 58(5):363-371. PubMed ID: 36729753
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0 T in the evaluation of the anterior cruciate ligament injury with additional views: comparison with two-dimensional fast spin-echo T2-weighted sequences.
    Park HJ; Lee SY; Park NH; Ahn JH; Chung EC; Kim SJ; Cha JG
    Acta Radiol; 2016 Nov; 57(11):1372-1379. PubMed ID: 25585852
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging.
    Gao F; Wen Z; Dou S; Kan X; Wei S; Ge Y
    Front Physiol; 2021; 12():759888. PubMed ID: 34992546
    [No Abstract]   [Full Text] [Related]  

  • 10. Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences.
    Altahawi FF; Blount KJ; Morley NP; Raithel E; Omar IM
    Skeletal Radiol; 2017 Jan; 46(1):7-15. PubMed ID: 27744578
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Usefulness of the fast spin-echo three-point Dixon (mDixon) image of the knee joint on 3.0-T MRI: comparison with conventional fast spin-echo T2 weighted image.
    Park HJ; Lee SY; Rho MH; Chung EC; Ahn JH; Park JH; Lee IS
    Br J Radiol; 2016 Jun; 89(1062):20151074. PubMed ID: 27008281
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Five-Minute Five-Sequence Knee MRI Using Combined Simultaneous Multislice and Parallel Imaging Acceleration: Comparison with 10-Minute Parallel Imaging Knee MRI.
    Del Grande F; Rashidi A; Luna R; Delcogliano M; Stern SE; Dalili D; Fritz J
    Radiology; 2021 Jun; 299(3):635-646. PubMed ID: 33825510
    [TBL] [Abstract][Full Text] [Related]  

  • 13. T2-weighted Imaging of the Breast at 1.5T Using Simultaneous Multi-slice Acceleration.
    Riffel J; Kannengiesser S; Schoenberg SO; Kaiser AK; Overhoff D; Riffel P; Kaiser CG
    Anticancer Res; 2021 Sep; 41(9):4423-4429. PubMed ID: 34475064
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences.
    Ucar M; Tokgoz N; Damar C; Alimli AG; Oncu F
    Jpn J Radiol; 2015 Feb; 33(2):94-101. PubMed ID: 25559932
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical experience with two-point mDixon turbo spin echo as an alternative to conventional turbo spin echo for magnetic resonance imaging of the pediatric knee.
    Kammen BF; Padua EM; Karakas SP; Hagar RW; Hitt DM; Pandya NK; Chung T
    Pediatr Radiol; 2019 May; 49(6):791-800. PubMed ID: 30725178
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MRI T2 Mapping of the Knee Providing Synthetic Morphologic Images: Comparison to Conventional Turbo Spin-Echo MRI.
    Roux M; Hilbert T; Hussami M; Becce F; Kober T; Omoumi P
    Radiology; 2019 Dec; 293(3):620-630. PubMed ID: 31573393
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved fat-suppression homogeneity with mDIXON turbo spin echo (TSE) in pediatric spine imaging at 3.0 T.
    Pokorney AL; Chia JM; Pfeifer CM; Miller JH; Hu HH
    Acta Radiol; 2017 Nov; 58(11):1386-1394. PubMed ID: 28165290
    [TBL] [Abstract][Full Text] [Related]  

  • 18. IDEAL 3D spoiled gradient echo of the articular cartilage of the knee on 3.0 T MRI: a comparison with conventional 3.0 T fast spin-echo T2 fat saturation image.
    Han CH; Park HJ; Lee SY; Chung EC; Choi SH; Yun JS; Rho MH
    Acta Radiol; 2015 Dec; 56(12):1479-86. PubMed ID: 25348476
    [TBL] [Abstract][Full Text] [Related]  

  • 19. MR imaging of the knee: Improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse.
    Radlbauer R; Lomoschitz F; Salomonowitz E; Eberhardt KE; Stadlbauer A
    Eur J Radiol; 2010 Aug; 75(2):e82-7. PubMed ID: 20096521
    [TBL] [Abstract][Full Text] [Related]  

  • 20. MRI of the lumbar spine: comparison of 3D isotropic turbo spin-echo SPACE sequence versus conventional 2D sequences at 3.0 T.
    Lee S; Jee WH; Jung JY; Lee SY; Ryu KS; Ha KY
    Acta Radiol; 2015 Feb; 56(2):174-81. PubMed ID: 24553584
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.