BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 29333202)

  • 1. Elasto-inertial migration of deformable capsules in a microchannel.
    Raffiee AH; Dabiri S; Ardekani AM
    Biomicrofluidics; 2017 Nov; 11(6):064113. PubMed ID: 29333202
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Elasto-Inertial Focusing Mechanisms of Particles in Shear-Thinning Viscoelastic Fluid in Rectangular Microchannels.
    Naderi MM; Barilla L; Zhou J; Papautsky I; Peng Z
    Micromachines (Basel); 2022 Dec; 13(12):. PubMed ID: 36557430
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Particle Focusing under Newtonian and Viscoelastic Flow in a Straight Rhombic Microchannel.
    Kwon JY; Kim T; Kim J; Cho Y
    Micromachines (Basel); 2020 Nov; 11(11):. PubMed ID: 33187390
    [TBL] [Abstract][Full Text] [Related]  

  • 4. "From the Edge to the Center": Viscoelastic Migration of Particles and Cells in a Strongly Shear-Thinning Liquid Flowing in a Microchannel.
    Del Giudice F; Sathish S; D'Avino G; Shen AQ
    Anal Chem; 2017 Dec; 89(24):13146-13159. PubMed ID: 29083161
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Particle Focusing in a Straight Microchannel with Non-Rectangular Cross-Section.
    Kim U; Kwon JY; Kim T; Cho Y
    Micromachines (Basel); 2022 Jan; 13(2):. PubMed ID: 35208276
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Elasto-inertial particle focusing under the viscoelastic flow of DNA solution in a square channel.
    Kim B; Kim JM
    Biomicrofluidics; 2016 Mar; 10(2):024111. PubMed ID: 27051468
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Concentration-controlled particle focusing in spiral elasto-inertial microfluidic devices.
    Xiang N; Ni Z; Yi H
    Electrophoresis; 2018 Jan; 39(2):417-424. PubMed ID: 28990196
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Flow of Non-Newtonian Fluids in a Single-Cavity Microchannel.
    Raihan MK; Jagdale PP; Wu S; Shao X; Bostwick JB; Pan X; Xuan X
    Micromachines (Basel); 2021 Jul; 12(7):. PubMed ID: 34357246
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Continuous separation of microparticles in a microfluidic channel via the elasto-inertial effect of non-Newtonian fluid.
    Nam J; Lim H; Kim D; Jung H; Shin S
    Lab Chip; 2012 Apr; 12(7):1347-54. PubMed ID: 22334376
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sheathless elasto-inertial particle focusing and continuous separation in a straight rectangular microchannel.
    Yang S; Kim JY; Lee SJ; Lee SS; Kim JM
    Lab Chip; 2011 Jan; 11(2):266-73. PubMed ID: 20976348
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Inertial migration and axial control of deformable capsules.
    Schaaf C; Stark H
    Soft Matter; 2017 May; 13(19):3544-3555. PubMed ID: 28443874
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Influence of non-Newtonian power law rheology on inertial migration of particles in channel flow.
    Hu X; Lin J; Chen D; Ku X
    Biomicrofluidics; 2020 Jan; 14(1):014105. PubMed ID: 31933715
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of microchannel structure and fluid properties on non-inertial particle migration.
    Maitri RV; De S; Koesen SP; Wyss HM; van der Schaaf J; Kuipers JAM; Padding JT; Peters EAJF
    Soft Matter; 2019 Mar; 15(12):2648-2656. PubMed ID: 30860218
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Inertial migration of a deformable capsule in an oscillatory flow in a microchannel.
    Lafzi A; Raffiee AH; Dabiri S
    Phys Rev E; 2020 Dec; 102(6-1):063110. PubMed ID: 33466115
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Elasto-inertial particle focusing in sinusoidal microfluidic channels.
    Chen D; Huang Q; Ni Z; Xiang N
    Electrophoresis; 2024 May; ():. PubMed ID: 38813845
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dean-flow-coupled elasto-inertial three-dimensional particle focusing under viscoelastic flow in a straight channel with asymmetrical expansion-contraction cavity arrays.
    Yuan D; Zhang J; Yan S; Pan C; Alici G; Nguyen NT; Li WH
    Biomicrofluidics; 2015 Jul; 9(4):044108. PubMed ID: 26339309
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High throughput single-cell and multiple-cell micro-encapsulation.
    Lagus TP; Edd JF
    J Vis Exp; 2012 Jun; (64):e4096. PubMed ID: 22733254
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Elasto-inertial focusing and particle migration in high aspect ratio microchannels for high-throughput separation.
    Tanriverdi S; Cruz J; Habibi S; Amini K; Costa M; Lundell F; Mårtensson G; Brandt L; Tammisola O; Russom A
    Microsyst Nanoeng; 2024; 10():87. PubMed ID: 38919163
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Continuous Microfluidic Particle Separation via Elasto-Inertial Pinched Flow Fractionation.
    Lu X; Xuan X
    Anal Chem; 2015 Jun; 87(12):6389-96. PubMed ID: 26005774
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Wall-mode instability in plane shear flow of viscoelastic fluid over a deformable solid.
    Chokshi P; Bhade P; Kumaran V
    Phys Rev E Stat Nonlin Soft Matter Phys; 2015 Feb; 91(2):023007. PubMed ID: 25768597
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.