These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
66 related articles for article (PubMed ID: 293357)
1. [Studies on orthodontic polyurethane ringlets. (Part 1) Examination of its physical properties (author's transl)]. Katoh H Shika Rikogaku Zasshi; 1978 Oct; 19(48):290-7. PubMed ID: 293357 [TBL] [Abstract][Full Text] [Related]
2. Mechanical stability of elastomeric polymers for blood pump applications. Hayashi K; Takano H; Matsuda T; Umezu M J Biomed Mater Res; 1985 Feb; 19(2):179-93. PubMed ID: 4077879 [TBL] [Abstract][Full Text] [Related]
3. [Studies on orthodontic polyurethane ringlets. (Part 2). Examination of its clinical application (author's transl)]. Kato H Kokubyo Gakkai Zasshi; 1980 Mar; 47(1):145-59. PubMed ID: 6931859 [No Abstract] [Full Text] [Related]
4. Biostability and blood-contacting properties of sulfonate grafted polyurethane and Biomer. Wabers HD; McCoy TJ; Okkema AT; Hergenrother RW; Wolf MF; Cooper SL J Biomater Sci Polym Ed; 1992; 4(2):107-33. PubMed ID: 1486064 [TBL] [Abstract][Full Text] [Related]
5. A low-temperature thermoplastic anti-bacterial medical orthotic material made of shape memory polyurethane ionomer: influence of ionic group. Meng Q; Hu J; Liu B; Zhu Y J Biomater Sci Polym Ed; 2009; 20(2):199-218. PubMed ID: 19154670 [TBL] [Abstract][Full Text] [Related]
6. [Studies on new superelastic NiTi orthodontic wire. (Part 1) Tensile and bend test (author's transl)]. Watanabe K Shika Rikogaku Zasshi; 1982 Jan; 23(61):47-57. PubMed ID: 6951898 [TBL] [Abstract][Full Text] [Related]
7. Flexural strength and moduli of hypoallergenic denture base materials. Pfeiffer P; Rolleke C; Sherif L J Prosthet Dent; 2005 Apr; 93(4):372-7. PubMed ID: 15798688 [TBL] [Abstract][Full Text] [Related]
8. [Synthesis, characterization and blood compatibility studies of biomedical aliphatic polyurethanes]. Du M; Li J; Wei Y; Xie X; He C; Fan C; Zhong Y Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Jun; 20(2):273-6. PubMed ID: 12856596 [TBL] [Abstract][Full Text] [Related]
9. A novel polyurethane-based root canal-obturation material and urethane acrylate-based root canal sealer--part I: synthesis and evaluation of mechanical and thermal properties. Hsieh KH; Liao KH; Lai EH; Lee BS; Lee CY; Lin CP J Endod; 2008 Mar; 34(3):303-5. PubMed ID: 18291281 [TBL] [Abstract][Full Text] [Related]
10. Effect of thermocycling on bond strength and elasticity of 4 long-term soft denture liners. Pinto JR; Mesquita MF; Henriques GE; de Arruda NĂ³bilo MA J Prosthet Dent; 2002 Nov; 88(5):516-21. PubMed ID: 12474002 [TBL] [Abstract][Full Text] [Related]
11. The effects of primers and surface bonding characteristics on the adhesion of polyurethane to two commonly used silicone elastomers. Chang PP; Hansen NA; Phoenix RD; Schneid TR J Prosthodont; 2009 Jan; 18(1):23-31. PubMed ID: 19166545 [TBL] [Abstract][Full Text] [Related]
12. In vivo evaluations of a new thromboresistant polyurethane for artificial heart blood pumps. Farrar DJ; Litwak P; Lawson JH; Ward RS; White KA; Robinson AJ; Rodvien R; Hill JD J Thorac Cardiovasc Surg; 1988 Feb; 95(2):191-200. PubMed ID: 3339889 [TBL] [Abstract][Full Text] [Related]
13. [Studies on the new orthodontic rubber materials. 3. Clinical application of tooth positioner made of castable type polyol cure polyurethane rubber (author's transl)]. Yoshii O Kokubyo Gakkai Zasshi; 1973 Jun; 40(2):103-21. PubMed ID: 4519984 [No Abstract] [Full Text] [Related]
14. Effects of strain rate and temperature on the mechanical properties of resin composites. Musanje L; Darvell BW Dent Mater; 2004 Oct; 20(8):750-65. PubMed ID: 15302456 [TBL] [Abstract][Full Text] [Related]
15. Comparative In vitro evaluation of two different preparations of small diameter polyurethane vascular grafts. Hsu Sh; Tseng Hj; Wu Ms Artif Organs; 2000 Feb; 24(2):119-28. PubMed ID: 10718765 [TBL] [Abstract][Full Text] [Related]
16. Effects of post-curing on mechanical properties of a composite. Powers JM; Smith LT; Eldiwany M; Ladd GD Am J Dent; 1993 Oct; 6(5):232-4. PubMed ID: 7880465 [TBL] [Abstract][Full Text] [Related]
17. Effect of water temperature during polymerization on strength of autopolymerizing resin. Ogawa T; Tanaka M; Koyano K J Prosthet Dent; 2000 Aug; 84(2):222-4. PubMed ID: 10946343 [TBL] [Abstract][Full Text] [Related]
18. VAD Biomer blood sacs: mechanical tests and ultrastructural observations. Bedini R; Chistolini P; De Angelis G; Formisano G; Caiazza S Med Prog Technol; 1993; 19(2):83-8. PubMed ID: 8107668 [TBL] [Abstract][Full Text] [Related]
19. A new generation of high flex life polyurethane urea for polymer heart valve--studies on in vivo biocompatibility and biodurability. Thomas V; Jayabalan M J Biomed Mater Res A; 2009 Apr; 89(1):192-205. PubMed ID: 18431755 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of sunlight stability of polyurethane elastomers for maxillofacial use. II. Chu CC; Fischer TE J Biomed Mater Res; 1979 Nov; 13(6):965-74. PubMed ID: 511864 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]