These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 29336181)

  • 1. Analytical and between-subject variation of thrombin generation measured by calibrated automated thrombography on plasma samples.
    Kristensen AF; Kristensen SR; Falkmer U; Münster AB; Pedersen S
    Scand J Clin Lab Invest; 2018 May; 78(3):175-179. PubMed ID: 29336181
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Thrombin generation in plasma of healthy adults and children: chromogenic versus fluorogenic thrombogram analysis.
    Devreese K; Wijns W; Combes I; Van kerckhoven S; Hoylaerts MF
    Thromb Haemost; 2007 Sep; 98(3):600-13. PubMed ID: 17849049
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurements of endogenous thrombin potential using the CAT method in cats: Reference values and influence of the direct factor Xa inhibitor apixaban.
    Mischke R; Teuber M; Tiede A
    Res Vet Sci; 2019 Dec; 127():113-121. PubMed ID: 31693942
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinical measurement of thrombin generation by calibrated automated thrombography requires contact factor inhibition.
    Luddington R; Baglin T
    J Thromb Haemost; 2004 Nov; 2(11):1954-9. PubMed ID: 15550027
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of pre-analytical variables in a commercial thrombin generation assay.
    Rodgers SE; Wong A; Gopal RD; Dale BJ; Duncan EM; McRae SJ
    Thromb Res; 2014 Jul; 134(1):160-4. PubMed ID: 24792772
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of tissue factor concentration on calibrated automated thrombography in the presence of inhibitor bypass agents.
    van Veen JJ; Gatt A; Bowyer AE; Cooper PC; Kitchen S; Makris M
    Int J Lab Hematol; 2009 Apr; 31(2):189-98. PubMed ID: 18190585
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of markers of coagulation activation and thrombin generation test in uncomplicated pregnancies.
    Joly B; Barbay V; Borg JY; Le Cam-Duchez V
    Thromb Res; 2013 Sep; 132(3):386-91. PubMed ID: 23962423
    [TBL] [Abstract][Full Text] [Related]  

  • 8. External validation of the MidiCAT variant of thrombography: Comparison with calibrated automated thrombography and study of the centrifugation scheme.
    Charles S; Guyotat D; Fontana P; Tardy B; Lecompte T; Chalayer E
    Front Cardiovasc Med; 2022; 9():998687. PubMed ID: 36337867
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of Two Thrombin Generation Methods, CAT and ST-Genesia, in Liver Transplant Patients.
    Roullet S; Labrouche S; Freyburger G
    Thromb Haemost; 2019 Jun; 119(6):899-905. PubMed ID: 31005063
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hypercoagulability (thrombin generation) in patients with cirrhosis is detected with ST-Genesia.
    Talon L; Sinegre T; Lecompte T; Pereira B; Massoulié S; Abergel A; Lebreton A
    J Thromb Haemost; 2020 Sep; 18(9):2177-2190. PubMed ID: 32558351
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Calibrated automated thrombin generation measurement in clotting plasma.
    Hemker HC; Giesen P; Al Dieri R; Regnault V; de Smedt E; Wagenvoord R; Lecompte T; Béguin S
    Pathophysiol Haemost Thromb; 2003; 33(1):4-15. PubMed ID: 12853707
    [TBL] [Abstract][Full Text] [Related]  

  • 12. PO-27 - Thrombin generation in pancreatic cancer and multiple myeloma with use of calibrated automated thrombography.
    Adesanya MA; Maraveyas A; Madden LA
    Thromb Res; 2016 Apr; 140 Suppl 1():S186. PubMed ID: 27161715
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reproducibility, stability, and biological variability of thrombin generation using calibrated automated thrombography in healthy dogs.
    Cuq B; Blois SL; Wood RD; Monteith G; Abrams-Ogg AC; Bédard C; Wood GA
    Vet Clin Pathol; 2018 Jun; 47(2):218-226. PubMed ID: 29578657
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Global coagulation tests: their applicability for measuring direct factor Xa- and thrombin inhibition and reversal of anticoagulation by prothrombin complex concentrate.
    Dinkelaar J; Patiwael S; Harenberg J; Leyte A; Brinkman HJ
    Clin Chem Lab Med; 2014 Nov; 52(11):1615-23. PubMed ID: 24902009
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Thrombin Generation in Fresh and Frozen-Thawed Platelet Poor Plasma - Is there a Difference?
    Kausche LE; Adler W; Zimmermann R; Hackstein H; Strasser EF
    Clin Lab; 2020 Jun; 66(6):. PubMed ID: 32538058
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monitoring thrombin generation: is addition of corn trypsin inhibitor needed?
    Spronk HM; Dielis AW; Panova-Noeva M; van Oerle R; Govers-Riemslag JW; Hamulyák K; Falanga A; Cate HT
    Thromb Haemost; 2009 Jun; 101(6):1156-62. PubMed ID: 19492161
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vitro effects of dalteparin on thrombin generation in canine plasma.
    Gara-Boivin C; Del Castillo JRE; Dunn ME; Bédard C
    Vet Clin Pathol; 2017 Sep; 46(3):442-450. PubMed ID: 28605123
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Suggestions for global coagulation assays for the assessment of COVID-19 associated hypercoagulability.
    van de Berg TW; Hulshof AM; Nagy M; van Oerle R; Sels JW; van Bussel B; Ten Cate H; Henskens Y; Spronk HMH;
    Thromb Res; 2021 May; 201():84-89. PubMed ID: 33662799
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of standardization and normalization on imprecision of calibrated automated thrombography: an international multicentre study.
    Dargaud Y; Luddington R; Gray E; Negrier C; Lecompte T; Petros S; Hogwood J; Bordet JC; Regnault V; Siegemund A; Baglin T
    Br J Haematol; 2007 Oct; 139(2):303-9. PubMed ID: 17897307
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Women with unexplained recurrent pregnancy loss do not have evidence of an underlying prothrombotic state: experience with calibrated automated thrombography and rotational thromboelastometry.
    Bennett SA; Bagot CN; Appiah A; Johns J; Ross J; Roberts LN; Patel RK; Arya R
    Thromb Res; 2014 May; 133(5):892-9. PubMed ID: 24613698
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.