482 related articles for article (PubMed ID: 29336902)
1. Surgical management of pulsatile tinnitus secondary to jugular bulb or sigmoid sinus diverticulum with review of literature.
Yeo WX; Xu SH; Tan TY; Low YM; Yuen HW
Am J Otolaryngol; 2018; 39(2):247-252. PubMed ID: 29336902
[TBL] [Abstract][Full Text] [Related]
2. Endovascular treatment of pulsatile tinnitus associated with transverse sigmoid sinus aneurysms and jugular bulb anomalies.
Trivelato FP; Araújo JF; Dos Santos Silva R; Rezende MT; Ulhôa AC; Castro GD
Interv Neuroradiol; 2015 Aug; 21(4):548-51. PubMed ID: 26111983
[TBL] [Abstract][Full Text] [Related]
3. Hydroxyapatite cement resurfacing the dehiscent jugular bulb: Novel treatment for pulsatile tinnitus.
DeHart AN; Shaia WT; Coelho DH
Laryngoscope; 2018 May; 128(5):1186-1190. PubMed ID: 28608387
[TBL] [Abstract][Full Text] [Related]
4. Sigmoid sinus diverticulum: a new surgical approach to the correction of pulsatile tinnitus.
Otto KJ; Hudgins PA; Abdelkafy W; Mattox DE
Otol Neurotol; 2007 Jan; 28(1):48-53. PubMed ID: 17195746
[TBL] [Abstract][Full Text] [Related]
5. Prevalence, Surgical Management, and Audiologic Impact of Sigmoid Sinus Dehiscence Causing Pulsatile Tinnitus.
Ettyreddy AR; Shew MA; Durakovic N; Chole RA; Herzog J; Buchman CA; Wick CC
Otol Neurotol; 2021 Jan; 42(1):82-91. PubMed ID: 33301285
[TBL] [Abstract][Full Text] [Related]
6. Endovascular treatment of two concomitant causes of pulsatile tinnitus: sigmoid sinus stenosis and ipsilateral jugular bulb diverticulum. Case report and literature review.
Signorelli F; Mahla K; Turjman F
Acta Neurochir (Wien); 2012 Jan; 154(1):89-92. PubMed ID: 22065197
[TBL] [Abstract][Full Text] [Related]
7. Clipping of sigmoid sinus diverticulum: how I do it.
Hassannia F; Carr SD; Busato GM; Rutka JA
J Laryngol Otol; 2018 Sep; 132(9):837-839. PubMed ID: 30078382
[TBL] [Abstract][Full Text] [Related]
8. The styloid process and the formation of sigmoid sinus diverticulum: is there a link?
Lou ZC
Braz J Otorhinolaryngol; 2021; 87(5):545-549. PubMed ID: 32044273
[TBL] [Abstract][Full Text] [Related]
9. A novel surgical technique for management of tinnitus due to high dehiscent jugular bulb.
El-Begermy MA; Rabie AN
Otolaryngol Head Neck Surg; 2010 Apr; 142(4):576-81. PubMed ID: 20304281
[TBL] [Abstract][Full Text] [Related]
10. Transmastoid Hydroxyapatite Resurfacing for Sigmoid Sinus Wall Anomalies Causing Pulsatile Tinnitus.
Newberry I; Highland J; DeTorres A; Gurgel R
Ann Otol Rhinol Laryngol; 2021 Aug; 130(8):885-891. PubMed ID: 33412915
[TBL] [Abstract][Full Text] [Related]
11. CT evaluation of unilateral pulsatile tinnitus with jugular bulb wall dehiscence.
Dai C; Zhao P; Ding H; Lv H; Qiu X; Li X; Xu N; Meng X; Wang G; Xie J; Yang Z; Gong S; Wang Z
Eur Radiol; 2023 Jun; 33(6):4464-4471. PubMed ID: 36648550
[TBL] [Abstract][Full Text] [Related]
12. Sigmoid sinus dehiscence resurfacing as treatment for pulsatile tinnitus.
Santa Maria PL
J Laryngol Otol; 2013 Jul; 127 Suppl 2():S57-9. PubMed ID: 23595093
[TBL] [Abstract][Full Text] [Related]
13. Pulsatile tinnitus due to an aneurysmatic diverticulum of the jugular bulb treated with the Woven EndoBridge device.
Drescher F; Maus V; Weber W; Fischer S
Interv Neuroradiol; 2020 Apr; 26(2):235-238. PubMed ID: 31645157
[TBL] [Abstract][Full Text] [Related]
14. A new therapeutic procedure for treatment of objective venous pulsatile tinnitus.
Sanchez TG; Murao M; de Medeiros IR; Kii M; Bento RF; Caldas JG; Alvarez CA; Raggiotto CH
Int Tinnitus J; 2002; 8(1):54-7. PubMed ID: 14763237
[TBL] [Abstract][Full Text] [Related]
15. Systematic Review of Temporal Bone-Resurfacing Techniques for Pulsatile Tinnitus Associated with Vascular Wall Anomalies.
Liu GS; Boursiquot BC; Blevins NH; Vaisbuch Y
Otolaryngol Head Neck Surg; 2019 May; 160(5):749-761. PubMed ID: 30667295
[TBL] [Abstract][Full Text] [Related]
16. Incidence of vascular anomalies and variants associated with unilateral venous pulsatile tinnitus in 242 patients based on dual-phase contrast-enhanced computed tomography.
Dong C; Zhao PF; Yang JG; Liu ZH; Wang ZC
Chin Med J (Engl); 2015 Mar; 128(5):581-5. PubMed ID: 25698187
[TBL] [Abstract][Full Text] [Related]
17. Endovascular treatment of jugular bulb diverticula causing debilitating pulsatile tinnitus.
Mortimer AM; Harrington T; Steinfort B; Faulder K
J Neurointerv Surg; 2016 Mar; 8(3):e11. PubMed ID: 25691694
[TBL] [Abstract][Full Text] [Related]
18. [2 cases of pulsatile tinnitus caused by sigmoid sinus diverticulum and literature review].
Zhao H; Liu Y; Yang Y; Zeng X; Li J; Qiu S; Zhang Z
Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2013 Oct; 27(19):1088-90. PubMed ID: 24417170
[TBL] [Abstract][Full Text] [Related]
19. Management of Sigmoid Sinus Associated Pulsatile Tinnitus: A Systematic Review of the Literature.
Wang AC; Nelson AN; Pino C; Svider PF; Hong RS; Chan E
Otol Neurotol; 2017 Dec; 38(10):1390-1396. PubMed ID: 29135862
[TBL] [Abstract][Full Text] [Related]
20. Hypotympanic Sound Baffle for Amelioration of Pulsatile Tinnitus due to Carotid and Jugular Bulb Dehiscence.
Liu GS; Blevins NH; Vaisbuch Y
Otol Neurotol; 2019 Aug; 40(7):920-926. PubMed ID: 31295200
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]