These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
220 related articles for article (PubMed ID: 29343120)
1. An update on the advancing high-throughput screening techniques for patch clamp-based ion channel screens: implications for drug discovery. Obergrussberger A; Goetze TA; Brinkwirth N; Becker N; Friis S; Rapedius M; Haarmann C; Rinke-Weiß I; Stölzle-Feix S; Brüggemann A; George M; Fertig N Expert Opin Drug Discov; 2018 Mar; 13(3):269-277. PubMed ID: 29343120 [TBL] [Abstract][Full Text] [Related]
2. Automated patch clamp in drug discovery: major breakthroughs and innovation in the last decade. Obergrussberger A; Friis S; Brüggemann A; Fertig N Expert Opin Drug Discov; 2021 Jan; 16(1):1-5. PubMed ID: 32646308 [No Abstract] [Full Text] [Related]
3. State-of-the-art automated patch clamp: heat activation, action potentials, and high throughput in ion channel screening. Stoelzle-Feix S Methods Mol Biol; 2014; 1183():65-80. PubMed ID: 25023302 [TBL] [Abstract][Full Text] [Related]
4. The suitability of high throughput automated patch clamp for physiological applications. Obergrussberger A; Rinke-Weiß I; Goetze TA; Rapedius M; Brinkwirth N; Becker N; Rotordam MG; Hutchison L; Madau P; Pau D; Dalrymple D; Braun N; Friis S; Pless SA; Fertig N J Physiol; 2022 Jan; 600(2):277-297. PubMed ID: 34555195 [TBL] [Abstract][Full Text] [Related]
5. High-throughput electrophysiological assays for voltage gated ion channels using SyncroPatch 768PE. Li T; Lu G; Chiang EY; Chernov-Rogan T; Grogan JL; Chen J PLoS One; 2017; 12(7):e0180154. PubMed ID: 28683073 [TBL] [Abstract][Full Text] [Related]
6. New strategies in ion channel screening for drug discovery: are there ways to improve its productivity? Farre C; Fertig N Expert Opin Drug Discov; 2014 Oct; 9(10):1103-7. PubMed ID: 25062795 [TBL] [Abstract][Full Text] [Related]
7. HTS techniques for patch clamp-based ion channel screening - advances and economy. Farre C; Fertig N Expert Opin Drug Discov; 2012 Jun; 7(6):515-24. PubMed ID: 22507077 [TBL] [Abstract][Full Text] [Related]
8. Reliable identification of cardiac liability in drug discovery using automated patch clamp: Benchmarking best practices and calibration standards for improved proarrhythmic assessment. Brinkwirth N; Takasuna K; Doi M; Becker N; Obergrussberger A; Friis S; Furukawa H; Hasegawa Y; Oka T; Ohtsuki A; Fertig N; Stoelzle-Feix S J Pharmacol Toxicol Methods; 2020 Sep; 105():106884. PubMed ID: 32565325 [TBL] [Abstract][Full Text] [Related]
10. Advances in ion channel high throughput screening: where are we in 2023? Dallas ML; Bell D Expert Opin Drug Discov; 2024 Mar; 19(3):331-337. PubMed ID: 38108110 [TBL] [Abstract][Full Text] [Related]
11. Using automated patch clamp electrophysiology platforms in ion channel drug discovery: an industry perspective. Rogers M; Obergrussberger A; Kondratskyi A; Fertig N Expert Opin Drug Discov; 2024 May; 19(5):523-535. PubMed ID: 38481119 [TBL] [Abstract][Full Text] [Related]
13. Renaissance of ion channel research and drug discovery by patch clamp automation. Fertig N; Farre C Future Med Chem; 2010 May; 2(5):691-5. PubMed ID: 21426196 [No Abstract] [Full Text] [Related]
14. QPatch: the missing link between HTS and ion channel drug discovery. Mathes C; Friis S; Finley M; Liu Y Comb Chem High Throughput Screen; 2009 Jan; 12(1):78-95. PubMed ID: 19149494 [TBL] [Abstract][Full Text] [Related]
15. Automated ion channel screening: patch clamping made easy. Farre C; Stoelzle S; Haarmann C; George M; Brüggemann A; Fertig N Expert Opin Ther Targets; 2007 Apr; 11(4):557-65. PubMed ID: 17373884 [TBL] [Abstract][Full Text] [Related]
16. State-of-the-Art Automated Patch Clamp Devices: Heat Activation, Action Potentials, and High Throughput in Ion Channel Screening. Stoelzle S; Obergrussberger A; Brüggemann A; Haarmann C; George M; Kettenhofen R; Fertig N Front Pharmacol; 2011; 2():76. PubMed ID: 22131976 [TBL] [Abstract][Full Text] [Related]
17. Reliable identification of cardiac conduction abnormalities in drug discovery using automated patch clamp II: Best practices for Nav1.5 peak current in a high throughput screening environment. Rotordam MG; Obergrussberger A; Brinkwirth N; Takasuna K; Becker N; Horváth A; Goetze TA; Rapedius M; Furukawa H; Hasegawa Y; Oka T; Fertig N; Stoelzle-Feix S J Pharmacol Toxicol Methods; 2021; 112():107125. PubMed ID: 34500078 [TBL] [Abstract][Full Text] [Related]
18. Industrializing electrophysiology: HT automated patch clamp on SyncroPatch® 96 using instant frozen cells. Polonchuk L Methods Mol Biol; 2014; 1183():81-92. PubMed ID: 25023303 [TBL] [Abstract][Full Text] [Related]
19. Application of High-Throughput Automated Patch-Clamp Electrophysiology to Study Voltage-Gated Ion Channel Function in Primary Cortical Cultures. Toh MF; Brooks JM; Strassmaier T; Haedo RJ; Puryear CB; Roth BL; Ouk K; Pin SS SLAS Discov; 2020 Jun; 25(5):447-457. PubMed ID: 32003306 [TBL] [Abstract][Full Text] [Related]
20. Contribution of Automated Technologies to Ion Channel Drug Discovery. Picones A; Loza-Huerta A; Segura-Chama P; Lara-Figueroa CO Adv Protein Chem Struct Biol; 2016; 104():357-378. PubMed ID: 27038379 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]