168 related articles for article (PubMed ID: 29360268)
1. The Monoclonal Anti-CD157 Antibody Clone SY11B5, Used for High Sensitivity Detection of PNH Clones on WBCs, Fails to Detect a Common Polymorphic Variant Encoded by BST-1.
Blaha J; Schwarz K; Fischer C; Schauwecker P; Höchsmann B; Schrezenmeier H; Anliker M
Cytometry B Clin Cytom; 2018 Jul; 94(4):652-659. PubMed ID: 29360268
[TBL] [Abstract][Full Text] [Related]
2. Utility of FLAER and CD157 in a five-color single-tube high sensitivity assay, for diagnosis of Paroxysmal Nocturnal Hemoglobinuria (PNH)-A standalone flow cytometry laboratory experience.
Seth N; Mahajan V; Kedia S; Sutar A; Sehgal K
Int J Lab Hematol; 2021 Apr; 43(2):259-265. PubMed ID: 33058446
[TBL] [Abstract][Full Text] [Related]
3. Use of CD157 in FLAER-based assays for high-sensitivity PNH granulocyte and PNH monocyte detection.
Sutherland DR; Acton E; Keeney M; Davis BH; Illingworth A
Cytometry B Clin Cytom; 2014 Jan; 86(1):44-55. PubMed ID: 23922226
[TBL] [Abstract][Full Text] [Related]
4. Re: Blaha J et al.: The monoclonal anti-CD157 antibody clone SY11B5, used for high sensitivity detection of PNH clones on WBCs, fails to detect a common polymorphic variant encoded by BST-1.
Sutherland DR; Musani R
Cytometry B Clin Cytom; 2019 Jan; 96(1):16-18. PubMed ID: 30353646
[No Abstract] [Full Text] [Related]
5. Performance Characteristics of a Non-Fluorescent Aerolysin-Based Paroxysmal Nocturnal Hemoglobinuria (PNH) Assay for Simultaneous Evaluation of PNH Neutrophils and PNH Monocytes by Flow Cytometry, Following Published PNH Guidelines.
Marinov I; Illingworth AJ; Benko M; Sutherland DR
Cytometry B Clin Cytom; 2018 Mar; 94(2):257-263. PubMed ID: 27294344
[TBL] [Abstract][Full Text] [Related]
6. Diagnosis of paroxysmal nocturnal hemoglobinuria with flowcytometry panels including CD157: Data from the real world.
Zhang Y; Ding J; Gu H; Guo M; Wu J; Xu H; Wang Z; Yang J; Tang G
Cytometry B Clin Cytom; 2020 Mar; 98(2):193-202. PubMed ID: 31571381
[TBL] [Abstract][Full Text] [Related]
7. Clinical relevance of CD157 for rapid and cost-effective simultaneous evaluation of PNH granulocytes and monocytes by flow cytometry.
Marinov I; Kohoutová M; Tkáčová V; Pešek A; Čermák J; Cetkovský P
Int J Lab Hematol; 2015 Apr; 37(2):231-7. PubMed ID: 24963875
[TBL] [Abstract][Full Text] [Related]
8. CD157 Can Replace CD24 and CD14 in a Single-Tube Flow-Cytometric Assay to Detect Paroxysmal Nocturnal Hemoglobinuria (PNH) Clones on Both Neutrophils and Monocytes: A Prospective Study From North India.
Deka R; Pati HP; Chandra D; Manivannan P; Chauhan R; Tyagi S; Saxena R
Cureus; 2022 Apr; 14(4):e23965. PubMed ID: 35415060
[TBL] [Abstract][Full Text] [Related]
9. [Contribution and limits of CD157 in the detection of the paroxysmal nocturnal hemoglobinuria clone: a case report].
Bahroun S; Lakhal FB; ElBorgi W; Salem SF; Achour M; Gouider E
Ann Biol Clin (Paris); 2021 Aug; 79(4):356-360. PubMed ID: 34427564
[TBL] [Abstract][Full Text] [Related]
10. High-sensitivity 5-, 6-, and 7-color PNH WBC assays for both Canto II and Navios platforms.
Sutherland DR; Ortiz F; Quest G; Illingworth A; Benko M; Nayyar R; Marinov I
Cytometry B Clin Cytom; 2018 Jul; 94(4):637-651. PubMed ID: 29381839
[TBL] [Abstract][Full Text] [Related]
11. Practical guidelines for the high-sensitivity detection and monitoring of paroxysmal nocturnal hemoglobinuria clones by flow cytometry.
Sutherland DR; Keeney M; Illingworth A
Cytometry B Clin Cytom; 2012 Jul; 82(4):195-208. PubMed ID: 22499484
[TBL] [Abstract][Full Text] [Related]
12. Comparison of High Sensitivity and Conventional Flow Cytometry for Diagnosing Overt Paroxysmal Nocturnal Hemoglobinuria and Detecting Minor Paroxysmal Nocturnal Hemoglobinuria Clones.
Park SH; Jeong J; Lee SH; Yoo DW; Choi Y; Jo JC; Lim JH
Ann Lab Med; 2019 Mar; 39(2):150-157. PubMed ID: 30430777
[TBL] [Abstract][Full Text] [Related]
13. High-Sensitivity Detection of PNH Red Blood Cells, Red Cell Precursors, and White Blood Cells.
Sutherland DR; Illingworth A; Keeney M; Richards SJ
Curr Protoc Cytom; 2015 Apr; 72():6.37.1-6.37.29. PubMed ID: 25827482
[TBL] [Abstract][Full Text] [Related]
14. Use of CD157 in FLAER-based assays for high-sensitivity PNH granulocyte and PNH monocyte detection.
Sutherland DR; Acton E; Keeney M; Davis BH; Illingworth A
Cytometry B Clin Cytom; 2013 Jul; ():. PubMed ID: 23893962
[TBL] [Abstract][Full Text] [Related]
15. Utility of CD157 as a Common Leukocytes Marker for Paroxysmal Nocturnal Hemoglobinuria Screening in a Single Tube Five Color Combination.
Rahman K; Gupta R; Harankhedkar S; Gupta T; Sarkar MK; Nityanand S
Indian J Hematol Blood Transfus; 2018 Apr; 34(2):304-309. PubMed ID: 29622874
[TBL] [Abstract][Full Text] [Related]
16. CD71 improves delineation of PNH type III, PNH type II, and normal immature RBCS in patients with paroxysmal nocturnal hemoglobinuria.
Sutherland DR; Richards SJ; Ortiz F; Nayyar R; Benko M; Marinov I; Illingworth A
Cytometry B Clin Cytom; 2020 Mar; 98(2):179-192. PubMed ID: 31705743
[TBL] [Abstract][Full Text] [Related]
17. Intra- and interlaboratory variability of paroxysmal nocturnal hemoglobinuria testing by flow cytometry following the 2012 Practical Guidelines for high-sensitivity paroxysmal nocturnal hemoglobinuria testing.
Marinov I; Kohoutová M; Tkáčová V; Lysák D; Holubová M; Stehlíková O; Železníková T; Žontar D; Illingworth A
Cytometry B Clin Cytom; 2013; 84(4):229-36. PubMed ID: 23325604
[TBL] [Abstract][Full Text] [Related]
18. CD157 is an important mediator of neutrophil adhesion and migration.
Funaro A; Ortolan E; Ferranti B; Gargiulo L; Notaro R; Luzzatto L; Malavasi F
Blood; 2004 Dec; 104(13):4269-78. PubMed ID: 15328157
[TBL] [Abstract][Full Text] [Related]
19. Multiparameter FLAER-based flow cytometry for screening of paroxysmal nocturnal hemoglobinuria enhances detection rates in patients with aplastic anemia.
Sachdeva MU; Varma N; Chandra D; Bose P; Malhotra P; Varma S
Ann Hematol; 2015 May; 94(5):721-8. PubMed ID: 25465235
[TBL] [Abstract][Full Text] [Related]
20. Development and evaluation of a stabilized whole-blood preparation as a process control material for screening of paroxysmal nocturnal hemoglobinuria by flow cytometry.
Richards SJ; Whitby L; Cullen MJ; Dickinson AJ; Granger V; Reilly JT; Hillmen P; Barnett D
Cytometry B Clin Cytom; 2009 Jan; 76(1):47-55. PubMed ID: 18777525
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]