These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 29364790)

  • 1. Commentaries on Viewpoint: Principles, insights, and potential pitfalls of the noninvasive determination of muscle oxidative capacity by near-infrared spectroscopy.
    Chung S; Nelson MD; Hamaoka T; Jacobs RA; Pearson J; Subudhi AW; Jenkins NT; Bartlett MF; Fitzgerald LF; Miehm JD; Kent JA; Lucero AA; Rowlands DS; Stoner L; McCully KK; Call J; Rodriguez-Miguelez P; Harris RA; Porcelli S; Rasica L; Marzorati M; Quaresima V; Ryan TE; Vernillo G; Millet GP; Malatesta D; Millet GY; Zuo L; Chuang CC
    J Appl Physiol (1985); 2018 Jan; 124(1):249-255. PubMed ID: 29364790
    [No Abstract]   [Full Text] [Related]  

  • 2. Last Word on Viewpoint: Principles, insights, and potential pitfalls of the noninvasive determination of muscle oxidative capacity by near-infrared spectroscopy.
    Adami A; Rossiter HB
    J Appl Physiol (1985); 2018 Jan; 124(1):256. PubMed ID: 29364791
    [No Abstract]   [Full Text] [Related]  

  • 3. Principles, insights, and potential pitfalls of the noninvasive determination of muscle oxidative capacity by near-infrared spectroscopy.
    Adami A; Rossiter HB
    J Appl Physiol (1985); 2018 Jan; 124(1):245-248. PubMed ID: 28684592
    [No Abstract]   [Full Text] [Related]  

  • 4. Time Domain Near Infrared Spectroscopy Device for Monitoring Muscle Oxidative Metabolism: Custom Probe and In Vivo Applications.
    Re R; Pirovano I; Contini D; Spinelli L; Torricelli A
    Sensors (Basel); 2018 Jan; 18(1):. PubMed ID: 29342097
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Evaluation of kinematic capability of different groups by detecting oxygen saturation of muscle using near infrared spectroscopy].
    Li Y; Qi HB; Shi JZ; Teng YC; Ding HS
    Guang Pu Xue Yu Guang Pu Fen Xi; 2010 Feb; 30(2):440-3. PubMed ID: 20384141
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Using near-infrared spectroscopy to explore cardiovascular function and muscle oxidative properties within people with Parkinson's disease.
    Harris DM
    J Physiol; 2022 Nov; 600(22):4807-4809. PubMed ID: 36183240
    [No Abstract]   [Full Text] [Related]  

  • 7. Noninvasive measures of oxidative metabolism on working human muscles by near-infrared spectroscopy.
    Hamaoka T; Iwane H; Shimomitsu T; Katsumura T; Murase N; Nishio S; Osada T; Kurosawa Y; Chance B
    J Appl Physiol (1985); 1996 Sep; 81(3):1410-7. PubMed ID: 8889781
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reliability of muscle blood flow and oxygen consumption response from exercise using near-infrared spectroscopy.
    Lucero AA; Addae G; Lawrence W; Neway B; Credeur DP; Faulkner J; Rowlands D; Stoner L
    Exp Physiol; 2018 Jan; 103(1):90-100. PubMed ID: 29034529
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Non-invasive quantitative assessment of oxidative metabolism in quadriceps muscles by near infrared spectroscopy.
    Ding H; Wang G; Lei W; Wang R; Huang L; Xia Q; Wu J
    Br J Sports Med; 2001 Dec; 35(6):441-4. PubMed ID: 11726485
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Near-infrared spectroscopy and indocyanine green derived blood flow index for noninvasive measurement of muscle perfusion during exercise.
    Habazettl H; Athanasopoulos D; Kuebler WM; Wagner H; Roussos C; Wagner PD; Ungruhe J; Zakynthinos S; Vogiatzis I
    J Appl Physiol (1985); 2010 Apr; 108(4):962-7. PubMed ID: 20110542
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Near infrared spectroscopy for noninvasive assessment of claudication.
    Kooijman HM; Hopman MT; Colier WN; van der Vliet JA; Oeseburg B
    J Surg Res; 1997 Sep; 72(1):1-7. PubMed ID: 9344707
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Non-invasive determination of human oxygen metabolism during exercise].
    Su C; Ding H; Wang P; Feng W; Feng M; Cao J
    Space Med Med Eng (Beijing); 1998 Apr; 11(2):92-6. PubMed ID: 11543236
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characterising skeletal muscle haemoglobin saturation during exercise using near-infrared spectroscopy in chronic kidney disease.
    Wilkinson TJ; White AEM; Nixon DGD; Gould DW; Watson EL; Smith AC
    Clin Exp Nephrol; 2019 Jan; 23(1):32-42. PubMed ID: 29961156
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Research on human movement with noninvasive tissue oximeter using near infrared spectroscopy].
    Lin H; Xi YB; Yu H
    Guang Pu Xue Yu Guang Pu Fen Xi; 2014 Jun; 34(6):1538-41. PubMed ID: 25358161
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reproducibility of near-infrared spectroscopy measurements of oxidative function and postexercise recovery kinetics in the medial gastrocnemius muscle.
    Southern WM; Ryan TE; Reynolds MA; McCully K
    Appl Physiol Nutr Metab; 2014 May; 39(5):521-9. PubMed ID: 24766233
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Delayed reoxygenation after maximal isometric handgrip exercise in high oxidative capacity muscle.
    Kime R; Hamaoka T; Sako T; Murakami M; Homma T; Katsumura T; Chance B
    Eur J Appl Physiol; 2003 Mar; 89(1):34-41. PubMed ID: 12627303
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Noninvasive measurement of forearm oxygen consumption during exercise by near infrared spectroscopy.
    De Blasi RA; Alviggi I; Cope M; Elwell C; Ferrari M
    Adv Exp Med Biol; 1994; 345():685-92. PubMed ID: 8079774
    [No Abstract]   [Full Text] [Related]  

  • 18. Muscle oxygen consumption at onset of exercise by near infrared spectroscopy in humans.
    Hamaoka T; Katsumura T; Murase N; Sako T; Higuchi H; Murakami M; Esaki K; Kime R; Homma T; Sugeta A; Kurosawa Y; Shimomitsu T; Chance B
    Adv Exp Med Biol; 2003; 530():475-83. PubMed ID: 14562743
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Muscle oxygen saturation heterogeneity among leg muscles during ramp exercise.
    Takagi S; Kime R; Niwayama M; Murase N; Katsumura T
    Adv Exp Med Biol; 2013; 765():273-278. PubMed ID: 22879044
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reliability of near-infrared spectroscopy for determining muscle oxygen saturation during exercise.
    Austin KG; Daigle KA; Patterson P; Cowman J; Chelland S; Haymes EM
    Res Q Exerc Sport; 2005 Dec; 76(4):440-9. PubMed ID: 16739682
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.