These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
106 related articles for article (PubMed ID: 29368796)
1. Survey of 5 mm small-field output factor measurements in Australia. Oliver CP; Butler DJ; Takau V; Williams I J Appl Clin Med Phys; 2018 Mar; 19(2):329-337. PubMed ID: 29368796 [TBL] [Abstract][Full Text] [Related]
2. Evaluation of the IAEA-TRS 483 protocol for the dosimetry of small fields (square and stereotactic cones) using multiple detectors. Smith CL; Montesari A; Oliver CP; Butler DJ J Appl Clin Med Phys; 2020 Feb; 21(2):98-110. PubMed ID: 31886615 [TBL] [Abstract][Full Text] [Related]
3. Comparison of the NMIJ and the ARPANSA standards for absorbed dose to water in high-energy photon beams. Shimizu M; Morishita Y; Kato M; Tanaka T; Kurosawa T; Takata N; Saito N; Ramanathan G; Harty PD; Oliver C; Wright T; Butler DJ Radiat Prot Dosimetry; 2015 Apr; 164(3):181-6. PubMed ID: 25209996 [TBL] [Abstract][Full Text] [Related]
4. Linear-accelerator X-ray output: a multicentre chamber-based intercomparison study in Australia and New Zealand. Ebert MA; Howlett SJ; Harrison K; Cornes D; Hamilton CS; Denham JD Australas Phys Eng Sci Med; 2008 Dec; 31(4):268-79. PubMed ID: 19239053 [TBL] [Abstract][Full Text] [Related]
5. Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators. Fox C; Simon T; Simon B; Dempsey JF; Kahler D; Palta JR; Liu C; Yan G Med Phys; 2010 Feb; 37(2):477-84. PubMed ID: 20229856 [TBL] [Abstract][Full Text] [Related]
6. Maintaining the accuracy of the (60)Co calibration service at the ARPANSA post source replacement in 2010. Oliver C; Butler D; Webb D; Wright T; Lye J; Ramanathan G; Harty P; Takau V Australas Phys Eng Sci Med; 2015 Jun; 38(2):325-30. PubMed ID: 25749989 [TBL] [Abstract][Full Text] [Related]
7. The Australian radiation protection and nuclear safety agency megavoltage photon thermoluminescence dosimetry postal audit service 2007-2010. Oliver CP; Butler DJ; Webb DV Australas Phys Eng Sci Med; 2012 Mar; 35(1):105-8. PubMed ID: 22302465 [TBL] [Abstract][Full Text] [Related]
8. The effect of small field output factor measurements on IMRT dosimetry. Azimi R; Alaei P; Higgins P Med Phys; 2012 Aug; 39(8):4691-4. PubMed ID: 22894393 [TBL] [Abstract][Full Text] [Related]
9. Dosimetric characterization of Elekta stereotactic cones. Borzov E; Nevelsky A; Bar-Deroma R; Orion I J Appl Clin Med Phys; 2018 Jan; 19(1):194-203. PubMed ID: 29266744 [TBL] [Abstract][Full Text] [Related]
10. Calculation of k(Q(clin),Q(msr) ) (f(clin),f(msr) ) for several small detectors and for two linear accelerators using Monte Carlo simulations. Francescon P; Cora S; Satariano N Med Phys; 2011 Dec; 38(12):6513-27. PubMed ID: 22149834 [TBL] [Abstract][Full Text] [Related]
11. Reference dosimetry data and modeling challenges for Elekta accelerators based on IROC-Houston site visit data. Kerns JR; Followill DS; Lowenstein J; Molineu A; Alvarez P; Taylor PA; Kry SF Med Phys; 2018 May; 45(5):2337-2344. PubMed ID: 29537634 [TBL] [Abstract][Full Text] [Related]
12. Measurement of LINAC 90 degrees head leakage radiation TVL values. Li Z; Mutic S; Low D Med Phys; 2006 Sep; 33(9):3541-5. PubMed ID: 17022250 [TBL] [Abstract][Full Text] [Related]
13. Dosimetric characterization of small fields using a plastic scintillator detector: A large multicenter study. Mancosu P; Pasquino M; Reggiori G; Masi L; Russo S; Stasi M Phys Med; 2017 Sep; 41():33-38. PubMed ID: 28385495 [TBL] [Abstract][Full Text] [Related]
14. Towards reference dosimetry for the MR-linac: magnetic field correction of the ionization chamber reading. Smit K; van Asselen B; Kok JG; Aalbers AH; Lagendijk JJ; Raaymakers BW Phys Med Biol; 2013 Sep; 58(17):5945-57. PubMed ID: 23938362 [TBL] [Abstract][Full Text] [Related]
15. Determination of output factors for stereotactic radiosurgery beams. Fan J; Paskalev K; Wang L; Jin L; Li J; Eldeeb A; Ma C Med Phys; 2009 Nov; 36(11):5292-300. PubMed ID: 19994537 [TBL] [Abstract][Full Text] [Related]
16. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method. Moignier C; Huet C; Makovicka L Med Phys; 2014 Jul; 41(7):071702. PubMed ID: 24989371 [TBL] [Abstract][Full Text] [Related]
17. Verification of representative data for output factors of SRS cones utilizing IAEA TRS 483 recommendations. Irmen P; Reft C; Fitzherbert C; Solin L; Hand C Phys Med Biol; 2019 Nov; 64(21):215011. PubMed ID: 31556402 [TBL] [Abstract][Full Text] [Related]
18. Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones. Bassinet C; Huet C; Derreumaux S; Brunet G; Chéa M; Baumann M; Lacornerie T; Gaudaire-Josset S; Trompier F; Roch P; Boisserie G; Clairand I Med Phys; 2013 Jul; 40(7):071725. PubMed ID: 23822429 [TBL] [Abstract][Full Text] [Related]
19. Experimental small field 6 MV output ratio analysis for various diode detector and accelerator combinations. Cranmer-Sargison G; Weston S; Sidhu NP; Thwaites DI Radiother Oncol; 2011 Sep; 100(3):429-35. PubMed ID: 21945858 [TBL] [Abstract][Full Text] [Related]
20. Characterization of a multi-axis ion chamber array. Simon TA; Kozelka J; Simon WE; Kahler D; Li J; Liu C Med Phys; 2010 Nov; 37(11):6101-11. PubMed ID: 21158322 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]