BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 29369133)

  • 21. An exploration of nursing practices related to care of orthopaedic external fixators (pin/wire sites) in the Australian context.
    Campbell F; Watt E
    Int J Orthop Trauma Nurs; 2020 Feb; 36():100711. PubMed ID: 31451403
    [No Abstract]   [Full Text] [Related]  

  • 22. Pin-tract infection during limb lengthening using external fixation.
    Antoci V; Ono CM; Antoci V; Raney EM
    Am J Orthop (Belle Mead NJ); 2008 Sep; 37(9):E150-4. PubMed ID: 18982187
    [TBL] [Abstract][Full Text] [Related]  

  • 23. In search of a standard for pin site care.
    McKenzie LL
    Orthop Nurs; 1999; 18(2):73-8. PubMed ID: 10410050
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Patient-reported symptoms of 'calm', 'irritated' and 'infected' skeletal external fixator pin site wound states; a cross-sectional study.
    Santy-Tomlinson J; Jomeen J; Ersser SJ
    Int J Orthop Trauma Nurs; 2019 May; 33():44-51. PubMed ID: 30885643
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Treatment of external fixation pins about the wrist: a prospective, randomized trial.
    Egol KA; Paksima N; Puopolo S; Klugman J; Hiebert R; Koval KJ
    J Bone Joint Surg Am; 2006 Feb; 88(2):349-54. PubMed ID: 16452747
    [TBL] [Abstract][Full Text] [Related]  

  • 26. External fixation: Role in decreasing postoperative complications of complex syndactyly release - A review of 18 patients.
    Artuso M; Mas V; Ilharreborde B; Mazda K; Jehanno P
    Orthop Traumatol Surg Res; 2019 Oct; 105(6):1187-1191. PubMed ID: 31353234
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Routine pin tract care in external fixation is unnecessary: a randomised, prospective, blinded controlled study.
    Camathias C; Valderrabano V; Oberli H
    Injury; 2012 Nov; 43(11):1969-73. PubMed ID: 22901422
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Pin Tract Infection Following Correction of Charcot Foot With Static Circular Fixation.
    Finkler ES; Kasia C; Kroin E; Davidson-Bell V; Schiff AP; Pinzur MS
    Foot Ankle Int; 2015 Nov; 36(11):1310-5. PubMed ID: 26223236
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A user-friendly method of pin site management for external fixators.
    Dayton P; Prins DB; Hensley N; Wienke J
    Foot Ankle Spec; 2011 Dec; 4(6):370-2. PubMed ID: 21926364
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The effectiveness of physician-directed external fixation pin site care in preventing pin site infection in a high-risk patient population.
    Schweinberger MH; Roukis TS
    Foot Ankle Spec; 2008 Aug; 1(4):218-21. PubMed ID: 19825721
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Calm, irritated or infected? The experience of the inflammatory states and symptoms of pin site infection and irritation during external fixation: a grounded theory study.
    Santy-Tomlinson J; Vincent M; Glossop N; Jomeen J; Pearcey P
    J Clin Nurs; 2011 Nov; 20(21-22):3163-73. PubMed ID: 21831107
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Protocols for the care of external fixator pin sites.
    Sims M; Saleh M
    Prof Nurse; 1996 Jan; 11(4):261-4. PubMed ID: 8552707
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Technique tip: postoperative pin care of external fixators.
    Hur J; Campbell RJ; DiGiovanni CW
    Foot Ankle Int; 2005 Dec; 26(12):1099-100. PubMed ID: 16390647
    [No Abstract]   [Full Text] [Related]  

  • 34. Pin site infection in orthopaedic external fixation devices.
    Walker J
    Br J Nurs; 2012 Feb 8-22; 21(3):148, 150-1. PubMed ID: 22584652
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Diluted povidone-iodine versus saline for dressing metal-skin interfaces in external fixation.
    Chan CK; Saw A; Kwan MK; Karina R
    J Orthop Surg (Hong Kong); 2009 Apr; 17(1):19-22. PubMed ID: 19398787
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison between types of dressing following catheter insertion and early exit-site infection in peritoneal dialysis.
    Figueiredo AE; de Mattos C; Saraiva C; Olandoski M; Barretti P; Pecoits Filho R; de Moraes TP;
    J Clin Nurs; 2017 Nov; 26(21-22):3658-3663. PubMed ID: 28122398
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Novel Use of Active Leptospermum Honey for Ringed Fixator Pin Site Care in Diabetic Charcot Deformity Patients.
    Lazarides AL; Hamid KS; Kerzner MS
    Foot Ankle Spec; 2018 Apr; 11(2):117-122. PubMed ID: 28506082
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Prevention of pin tract infection in external stainless steel fixator frames using electric current in a goat model.
    van der Borden AJ; Maathuis PG; Engels E; Rakhorst G; van der Mei HC; Busscher HJ; Sharma PK
    Biomaterials; 2007 Apr; 28(12):2122-6. PubMed ID: 17258314
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Pin care using the Ilizarov apparatus: recommended treatment plan in Kurgan, Russia.
    Grant AD; Atar D; Lehman WB
    Bull Hosp Jt Dis; 1992; 52(1):18-20. PubMed ID: 1422437
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dressings for the prevention of surgical site infection.
    Dumville JC; Walter CJ; Sharp CA; Page T
    Cochrane Database Syst Rev; 2011 Jul; (7):CD003091. PubMed ID: 21735390
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.