These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 2937537)

  • 21. Probe exchange catheter used for angioplasty of total coronary artery occlusions.
    Kiemeneij F; Suwarganda JS; van der Wieken LR
    Cathet Cardiovasc Diagn; 1990 Apr; 19(4):289-93. PubMed ID: 2139804
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Guiding catheter exchange during coronary angioplasty.
    Warren SG; Barnett JC
    Cathet Cardiovasc Diagn; 1990 Jul; 20(3):212-5. PubMed ID: 2364422
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Coronary perfusion in acute vascular occlusion within the scope of transluminal coronary angioplasty].
    Hopf R; Kunkel B; Schneider M; Kaltenbach M
    Z Kardiol; 1985 Oct; 74(10):580-4. PubMed ID: 2933888
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Application of a tapered teflon dilator to percutaneous transluminal coronary angioplasty.
    Garnic JD; Polito SS; Lee DW; Tonnemacher DP; O'Connor LR
    Cathet Cardiovasc Diagn; 1988; 14(2):92-5. PubMed ID: 2966679
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Magnum Meier wires with Crag Fx wire catheter for total occlusive coronary arteries.
    Kitazume H; Kubo I; Iwama T
    Cathet Cardiovasc Diagn; 1997 Feb; 40(2):198-201. PubMed ID: 9047067
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Coronary angioplasty of bifurcational stenoses: a new approach utilizing a single-guide, double-probe technique: case reports.
    DiSciascio G; Goudreau E; Vetrovec GW
    Angiology; 1990 Feb; 41(2):145-50. PubMed ID: 2306007
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Percutaneous transluminal coronary angioplasty using a combined "balloon-on-a-wire" system and exchange guidewire technique.
    de Marchena E; Stang RB; Schob A; Topaz O; Chakko S; Mallon S; Kessler KM
    Cathet Cardiovasc Diagn; 1989 Nov; 18(3):183-6. PubMed ID: 2590937
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Experience with operative transluminal balloon-catheter dilatation of the coronary arteries.
    Mills NL; Doyle D
    Am Heart J; 1984 Apr; 107(4):838-40. PubMed ID: 6230913
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The balloon on a wire device: a new ultra-low-profile coronary angioplasty system/concept.
    Myler RK; Mooney MR; Stertzer SH; Clark DA; Hidalgo BO; Fishman J
    Cathet Cardiovasc Diagn; 1988; 14(2):135-40. PubMed ID: 2966676
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Management of coronary occlusion during angioplasty: stabilization using a guide wire.
    Tommaso CL; Singleton RT
    Cathet Cardiovasc Diagn; 1987; 13(6):391-3. PubMed ID: 2961451
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Modified crush technique with double kissing balloon inflation (sleeve technique): a novel technique for coronary bifurcation lesions.
    Jim MH; Ho HH; Miu R; Chow WH
    Catheter Cardiovasc Interv; 2006 Mar; 67(3):403-9. PubMed ID: 16489571
    [TBL] [Abstract][Full Text] [Related]  

  • 32. "Crossing balloons:" a new technique for complex angioplasty.
    Nakhjavan FK; Wertheimer JH; Goldman A
    J Am Coll Cardiol; 1986 Oct; 8(4):980-1. PubMed ID: 2944938
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Use of a hollow wire to facilitate angioplasty of occluded vessels.
    Smith LD; Katritsis D; Webb-Peploe MM
    Br Heart J; 1989 Apr; 61(4):326-30. PubMed ID: 2523718
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Parallel angioplasty dilatation catheter and guide wire: a new technique for the dilatation of calcified coronary arteries.
    Yazdanfar S; Ledley GS; Alfieri A; Strauss C; Kotler MN
    Cathet Cardiovasc Diagn; 1993 Jan; 28(1):72-5. PubMed ID: 8416337
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Percutaneous transluminal angioplasty of a large septal artery.
    Comazzi JL; Jang GC; Marsa RJ; Willis WH; Anderson DL; Wareham EE
    Cathet Cardiovasc Diagn; 1983; 9(2):181-6. PubMed ID: 6221803
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [An improved guide catheter for percutaneous transluminal coronary angioplasty].
    Harmjanz D; Werner PC
    Z Kardiol; 1989 Feb; 78(2):78-80. PubMed ID: 2524137
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Dilating guide wire: use of a new ultra-low-profile percutaneous transluminal coronary angioplasty system.
    Rizzo TF; Ciccone J; Werres R
    Cathet Cardiovasc Diagn; 1989 Apr; 16(4):258-62. PubMed ID: 2523245
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Efficacy of a new angioplasty catheter for severely narrowed coronary lesions.
    Thomas ES; Williams DO; Neiderman AL; Douglas JS; King SB
    J Am Coll Cardiol; 1988 Sep; 12(3):694-702. PubMed ID: 2969929
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Opening of chronic coronary artery occlusions with a recanalization catheter].
    Sievert H; Köhler KP; Kober G; Kaltenbach M
    Dtsch Med Wochenschr; 1988 Nov; 113(44):1703-7. PubMed ID: 2972533
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [High-frequency rotational atherectomy in coronary heart disease].
    Erbel R; O'Neil W; Auth D; Haude M; Nixdorff U; Dietz U; Rupprecht HJ; Tschollar W; Meyer J
    Dtsch Med Wochenschr; 1989 Mar; 114(13):487-95. PubMed ID: 2522386
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.