These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 29376323)

  • 1. In Situ Monitoring of Pb
    Ma X; Armas SM; Soliman M; Lytle DA; Chumbimuni-Torres K; Tetard L; Lee WH
    Environ Sci Technol; 2018 Feb; 52(4):2126-2133. PubMed ID: 29376323
    [TBL] [Abstract][Full Text] [Related]  

  • 2.
    Ma X; Lee WH; Lytle DA
    Meas Sci Technol; 2017 Feb; 28(2):. PubMed ID: 30799910
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microelectrode Investigation on the Corrosion Initiation at Lead-Brass Galvanic Interfaces in Chlorinated Drinking Water.
    Ma X; Lytle DA; Lee WH
    Langmuir; 2019 Oct; 35(40):12947-12954. PubMed ID: 31498996
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Corrosive microenvironments at lead solder surfaces arising from galvanic corrosion with copper pipe.
    Nguyen CK; Stone KR; Dudi A; Edwards MA
    Environ Sci Technol; 2010 Sep; 44(18):7076-81. PubMed ID: 20738129
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Thermo-mechanical processing of brass components for potable-water usage increases risks of Pb leaching.
    Siu KW; Kwok JCM; Ngan AHW
    Water Res; 2020 Nov; 186():116414. PubMed ID: 32947102
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Prediction of lead leaching from galvanic corrosion of lead-containing components in copper pipe drinking water supply systems.
    Chang L; Lee JHW; Fung YS
    J Hazard Mater; 2022 Aug; 436():129169. PubMed ID: 35739706
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mineralogical Evidence of Galvanic Corrosion in Drinking Water Lead Pipe Joints.
    DeSantis MK; Triantafyllidou S; Schock MR; Lytle DA
    Environ Sci Technol; 2018 Mar; 52(6):3365-3374. PubMed ID: 29446300
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improving Electrochemical Pb
    Hwang JH; Islam MA; Choi H; Ko TJ; Rodriguez KL; Chung HS; Jung Y; Lee WH
    Anal Chem; 2019 Sep; 91(18):11770-11777. PubMed ID: 31333017
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of pipeline geometry, sample volume, and flow rate on pb monitoring outcomes in copper pipe drinking water supply systems.
    Chang L
    Water Res; 2022 Aug; 222():118890. PubMed ID: 35933812
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An All-Solid-State Silicate Ion-Selective Electrode Using PbSiO₃ as a Sensitive Membrane.
    Wu R; Chen XG; Tao C; Huang Y; Ye Y; Wang Q; Zhou Y; Jin Q; Cai W
    Sensors (Basel); 2019 Jan; 19(3):. PubMed ID: 30691210
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Lead contamination of potable water due to nitrification.
    Zhang Y; Griffin A; Rahman M; Camper A; Baribeau H; Edwards M
    Environ Sci Technol; 2009 Mar; 43(6):1890-5. PubMed ID: 19368188
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Corrosion control in water supply systems: effect of pH, alkalinity, and orthophosphate on lead and copper leaching from brass plumbing.
    Tam YS; Elefsiniotis P
    J Environ Sci Health A Tox Hazard Subst Environ Eng; 2009 Oct; 44(12):1251-60. PubMed ID: 19847713
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of water treatment on the contribution of faucets to dissolved and particulate lead release at the tap.
    Cartier C; Nour S; Richer B; Deshommes E; Prévost M
    Water Res; 2012 Oct; 46(16):5205-16. PubMed ID: 22863027
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Identification of the sources of metal (lead) contamination in drinking waters in north-eastern Tasmania using lead isotopic compositions.
    Harvey PJ; Handley HK; Taylor MP
    Environ Sci Pollut Res Int; 2015 Aug; 22(16):12276-88. PubMed ID: 25895456
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Variability and sampling of lead (Pb) in drinking water: Assessing potential human exposure depends on the sampling protocol.
    Triantafyllidou S; Burkhardt J; Tully J; Cahalan K; DeSantis M; Lytle D; Schock M
    Environ Int; 2021 Jan; 146():106259. PubMed ID: 33395926
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Platinum electrode coated with a bentonite-carbon composite as an environmental sensor for detection of lead.
    Abbaspour A; Izadyar A
    Anal Bioanal Chem; 2006 Nov; 386(5):1559-65. PubMed ID: 16983532
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of fluoridation and disinfection agent combinations on lead leaching from leaded-brass parts.
    Maas RP; Patch SC; Christian AM; Coplan MJ
    Neurotoxicology; 2007 Sep; 28(5):1023-31. PubMed ID: 17697714
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A highly selective lead-sensitive electrode with solid contact based on ionic liquid.
    Wardak C
    J Hazard Mater; 2011 Feb; 186(2-3):1131-5. PubMed ID: 21168969
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Groundwater contamination from well points -- an experience from the Norwegian groundwater monitoring network.
    Jaeger Ø; Grimstvedt A; Frengstad B; Reimann C
    Sci Total Environ; 2006 Aug; 367(1):437-40. PubMed ID: 16580048
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Distribution system water age can create premise plumbing corrosion hotspots.
    Masters S; Parks J; Atassi A; Edwards MA
    Environ Monit Assess; 2015 Sep; 187(9):559. PubMed ID: 26251058
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.