108 related articles for article (PubMed ID: 29376499)
1. Reply to Comment on 'On the correct use of stepped-sine excitations for the measurement and identification of time-varying bioimpedance'.
Louarroudi E; Sanchez B
Physiol Meas; 2018 Feb; 39(2):028002. PubMed ID: 29376499
[TBL] [Abstract][Full Text] [Related]
2. On the correct use of stepped-sine excitations for the measurement of time-varying bioimpedance.
Láng GG; Zalka D
Physiol Meas; 2018 Feb; 39(2):028001. PubMed ID: 29376503
[TBL] [Abstract][Full Text] [Related]
3. On the correct use of stepped-sine excitations for the measurement of time-varying bioimpedance.
Louarroudi E; Sanchez B
Physiol Meas; 2017 Feb; 38(2):N73-N80. PubMed ID: 28005012
[TBL] [Abstract][Full Text] [Related]
4. Time-invariant measurement of time-varying bioimpedance using vector impedance analysis.
Sanchez B; Louarroudi E; Pintelon R
Physiol Meas; 2015 Mar; 36(3):595-620. PubMed ID: 25700023
[TBL] [Abstract][Full Text] [Related]
5. A new measuring and identification approach for time-varying bioimpedance using multisine electrical impedance spectroscopy.
Sanchez B; Louarroudi E; Jorge E; Cinca J; Bragos R; Pintelon R
Physiol Meas; 2013 Mar; 34(3):339-57. PubMed ID: 23442821
[TBL] [Abstract][Full Text] [Related]
6. A pilot spectroscopy study on time-varying bioimpedance during electrically-induced muscle contraction.
Sanchez B; Li J; Geisbush T; Bragos R; Rutkove SB
Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():3739-42. PubMed ID: 25570804
[TBL] [Abstract][Full Text] [Related]
7. A high accuracy broadband measurement system for time resolved complex bioimpedance measurements.
Kaufmann S; Malhotra A; Ardelt G; Ryschka M
Physiol Meas; 2014 Jun; 35(6):1163-80. PubMed ID: 24845882
[TBL] [Abstract][Full Text] [Related]
8. Harmonic impedance spectra identification from time-varying bioimpedance: theory and validation.
Sanchez B; Louarroudi E; Bragos R; Pintelon R
Physiol Meas; 2013 Oct; 34(10):1217-38. PubMed ID: 24021716
[TBL] [Abstract][Full Text] [Related]
9. Novel approach of processing electrical bioimpedance data using differential impedance analysis.
Sanchez B; Bandarenka AS; Vandersteen G; Schoukens J; Bragos R
Med Eng Phys; 2013 Sep; 35(9):1349-57. PubMed ID: 23601379
[TBL] [Abstract][Full Text] [Related]
10. Multi-frequency simultaneous measurement of bioimpedance spectroscopy based on a low crest factor multisine excitation.
Yang Y; Zhang F; Tao K; Wang L; Wen H; Teng Z
Physiol Meas; 2015 Mar; 36(3):489-501. PubMed ID: 25679488
[TBL] [Abstract][Full Text] [Related]
11. Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods.
Jaffrin MY; Morel H
Med Eng Phys; 2008 Dec; 30(10):1257-69. PubMed ID: 18676172
[TBL] [Abstract][Full Text] [Related]
12. Circular motion analysis of time-varying bioimpedance.
Sanchez B; Louarroudi E; Rutkove SB; Pintelon R
Physiol Meas; 2015 Nov; 36(11):2353-67. PubMed ID: 26489699
[TBL] [Abstract][Full Text] [Related]
13. Multi-channel bioimpedance spectroscopy based on orthogonal baseband shifting.
Menden T; Rumpf M; Korn L; Leonhardt S; Walter M
Physiol Meas; 2021 Jun; 42(6):. PubMed ID: 34020443
[No Abstract] [Full Text] [Related]
14. Wide-Range Filter-Based Sinusoidal Wave Synthesizer for Electrochemical Impedance Spectroscopy Measurements.
Chia-Ling Wei ; Yi-Wen Wang ; Bin-Da Liu
IEEE Trans Biomed Circuits Syst; 2014 Jun; 8(3):442-50. PubMed ID: 24043398
[TBL] [Abstract][Full Text] [Related]
15. The differential Howland current source with high signal to noise ratio for bioimpedance measurement system.
Liu J; Qiao X; Wang M; Zhang W; Li G; Lin L
Rev Sci Instrum; 2014 May; 85(5):055111. PubMed ID: 24880419
[TBL] [Abstract][Full Text] [Related]
16. Measurement of hand volume by bioelectrical impedance spectroscopy.
Ward LC; Dylke ES; Kilbreath SL
Lymphat Res Biol; 2012 Jun; 10(2):81-6. PubMed ID: 22720663
[TBL] [Abstract][Full Text] [Related]
17. In vivo electrical bioimpedance characterization of human lung tissue during the bronchoscopy procedure. A feasibility study.
Sanchez B; Vandersteen G; Martin I; Castillo D; Torrego A; Riu PJ; Schoukens J; Bragos R
Med Eng Phys; 2013 Jul; 35(7):949-57. PubMed ID: 23058287
[TBL] [Abstract][Full Text] [Related]
18. Use of impedance ratios to assess hand swelling in lymphoedema.
Dylke ES; Alsobayel H; Ward LC; Liu M; Webb E; Kilbreath SL
Phlebology; 2014 Mar; 29(2):83-9. PubMed ID: 23188815
[TBL] [Abstract][Full Text] [Related]
19. Novel estimation of the electrical bioimpedance using the local polynomial method. Application to in vivo real-time myocardium tissue impedance characterization during the cardiac cycle.
Sanchez B; Schoukens J; Bragos R; Vandersteen G
IEEE Trans Biomed Eng; 2011 Dec; 58(12):3376-85. PubMed ID: 21878408
[TBL] [Abstract][Full Text] [Related]
20. Broadband discrete-level excitations for improved extraction of information in bioimpedance measurements.
Min M; Paavle T
Physiol Meas; 2014 Jun; 35(6):997-1010. PubMed ID: 24844381
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]